Neural respiratory drive assessed by measuring the diaphragm electromyography in infants weaning from mechanical ventialtion

K. Swist-Szulik, Z. Kassim, C. Reilly, J. Moxham, A. Greenough, G. Rafferty (London, United Kingdom)

Source: Annual Congress 2009 - Respiratory disorders of the newborn
Session: Respiratory disorders of the newborn
Session type: Thematic Poster Session
Number: 4039
Disease area: Paediatric lung diseases, Respiratory critical care

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
K. Swist-Szulik, Z. Kassim, C. Reilly, J. Moxham, A. Greenough, G. Rafferty (London, United Kingdom). Neural respiratory drive assessed by measuring the diaphragm electromyography in infants weaning from mechanical ventialtion. Eur Respir J 2009; 34: Suppl. 53, 4039

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Analysis of the involvement of respiratory muscles through the TIE index in patients in ventilatory weaning with surface electromyography
Source: International Congress 2018 – Muscles and diaphragm, and quality improvement
Year: 2018

Diaphragmatic weakness contributes to prolonged mechanical ventilation in critical ill patients
Source: International Congress 2016 – Epidemiological and clinical data regarding the modern management of chronic lung diseases
Year: 2016


Prediction of infant extubation using surface diaphragm electromyography
Source: International Congress 2019 – The new-born lung: short- and long-term pathological entities
Year: 2019



Usefulness of electrical activity of diaphragm and ability to wean from ventilator
Source: International Congress 2016 – Diagnostic and therapeutic challenges in acute respiratory failure
Year: 2016


Prediction of successful weaning from mechanical ventilation by continuous ultrasound monitoring of diaphragm excursion
Source: Virtual Congress 2021 – Respiratory failure in COVID19 and beyond
Year: 2021


Effects of muscle electrical stimulation on respiratory muscle in patients with prolonged mechanical ventilation
Source: Virtual Congress 2020 – Physiotherapy in acute respiratory care
Year: 2020

Measurement validity of an electronic inspiratory loading device during inspiratory muscle training in weaning failure patients
Source: Virtual Congress 2020 – Physiotherapy in acute respiratory care
Year: 2020


Measurement validity of an electronic inspiratory loading device during inspiratory muscle training in weaning failure patients
Source: Respiratory Failure and Mechanical Ventilation Conference 2020
Year: 2020



Lung function and electromyography of the respiratory muscles
Source: Eur Respir Mon; 2010: 47: 183–194
Year: 2010

Diaphragmatic ultrasonography during spontaneous breathing trials in critically ill patients: Can it identify weaning failure?
Source: International Congress 2016 – Diagnostic and therapeutic challenges in acute respiratory failure
Year: 2016


Assessment of ventilatory mechanics in respiratory muscle weakness using structured light plethysmography
Source: International Congress 2018 – New methods and concepts in tests of lung and respiratory muscle function
Year: 2018

Use of the oesophageal diaphragm electromyogram to assess levels of neural respiratory drive in patients with neuromuscular disease
Source: Eur Respir J 2007; 30: Suppl. 51, 183s
Year: 2007

Changes in neural respiratory drive during initiation of domicilary non-invasive ventilation (NIV)
Source: Annual Congress 2013 –New evidence for NIV in the chronic setting
Year: 2013

Inspiratory muscle function in neuromuscular patients after non invasive mechanical ventilation
Source: Annual Congress 2009 - Noninvasive ventilation: new and old aspects
Year: 2009


Respiratory variability during weaning from mechanical ventilation
Source: Eur Respir J 2001; 18: Suppl. 33, 239s
Year: 2001

Simplifying the measurement of neural respiratory drive index: parasternal electromyogram to measure respiratory rate
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


Evaluating respiratory mechanics by forced oscillation via laryngeal mask in rabbits
Source: International Congress 2019 – Lung function testing: from experimental investigations to clinical applications
Year: 2019

Noninvasive evaluation of the respiratory muscular function by means of mechanomyographic signals of the diaphragm muscle in COPD patients
Source: Annual Congress 2010 - Advances in lung function I
Year: 2010


Anesthesia induced changes of respiratory mechanics in rats measured by impulse oscillometry
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012