Validation of the assessment of flow limitation at rest by overlapping of the tidal and maximal flow volume curves

L. Malagrino‘, E. Mariancini, F. Costa, S. Angiolotti, P. Paggiaro, A. Celi (Pisa, Italy)

Source: Annual Congress 2009 - Quality control in lung function and new developments
Session: Quality control in lung function and new developments
Session type: E-Communication Session
Number: 1856
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
L. Malagrino‘, E. Mariancini, F. Costa, S. Angiolotti, P. Paggiaro, A. Celi (Pisa, Italy). Validation of the assessment of flow limitation at rest by overlapping of the tidal and maximal flow volume curves. Eur Respir J 2009; 34: Suppl. 53, 1856

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
An evaluation of peak expiratory flow measured on the smart peak flow meter
Source: Virtual Congress 2020 – Occupational exposure as a cause of respiratory disease
Year: 2020


Volume acceleration profile in expiratory flow limitation during mechanical ventilation
Source: Eur Respir J 2001; 18: Suppl. 33, 480s
Year: 2001

Bronchodilatation and natural variation in maximal in-and expiratory flow volume curves in patients with stable COPD
Source: Eur Respir J 2002; 20: Suppl. 38, 539s
Year: 2002

Reproducibility in parameters of forced inspiratory flow
Source: Annual Congress 2009 - Functional insights into COPD
Year: 2009

Regional expiratory flow limitation during spontaneous breathing: comparison of overall and regional lung function
Source: Eur Respir J 2001; 18: Suppl. 33, 94s
Year: 2001

Recording flow in the first second of a maximal forced expiratory manoeuvre: influence of frequency content
Source: Eur Respir J 2002; 19: 530-533
Year: 2002



The reliability of peak expiratory flow monitoring
Source: Eur Respir J 2005; 26: Suppl. 49, 602s
Year: 2005

Variability of the peak inspiratory flow (PIF) measurement
Source: Eur Respir J 2001; 18: Suppl. 33, 204s
Year: 2001

Continuous measurement of peak expiratory flow – to whom and how long?
Source: Annual Congress 2007 - Assessing asthma severity and control in children
Year: 2007


Comparison of peak expiratory flow values between Cipla peak flow master and Wrights peak flow meter
Source: Eur Respir J 2006; 28: Suppl. 50, 221s
Year: 2006

Volume-elastic pressure curve as a diagnostic tool of expiratory flow limitation during mechanical ventilation
Source: Eur Respir J 2004; 24: Suppl. 48, 675s
Year: 2004

Peak expiratory flow value and relationships between functional parameters in COPD
Source: Eur Respir J 2006; 28: Suppl. 50, 808s
Year: 2006

Peak in- and expiratory flow rates: reproducibility and reference values in adults
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


The clinical significance and respiratory physiological characteristics of small platform in early forced expiratory flow - volume curve
Source: Eur Respir J 2002; 20: Suppl. 38, 300s
Year: 2002

Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest
Source: Eur Respir J 2001; 17: 1120-1127
Year: 2001



Exercise test results and forced expiratory flow rates at low lung volumes
Source: Eur Respir J 2002; 20: Suppl. 38, 286s
Year: 2002

Quantification of expiratory flow limitation associated with exercise-induced ventilatory strain
Source: Annual Congress 2009 - New developments in exercise physiology
Year: 2009



Physiological techniques for detecting expiratory flow limitation during tidal breathing
Source: Eur Respir Rev 2011; 20: 147-155
Year: 2011



Contribution of the forced oscillations technique in the detection of expiratory flow limitation during spontaneous respiration
Source: Eur Respir J 2004; 24: Suppl. 48, 575s
Year: 2004