Relationship between endotracheal tube leakage and displayed tidal volume in neonatal ventilators

R. Mahmoud, H. Fischer, H. Proquitté, N. Fawethy, S. Hadhood, G. Schmalisch (Sohag, Egypt; Berlin, Germany)

Source: Annual Congress 2009 - Respiratory physiology in infants and preschool children, in health and disease
Session: Respiratory physiology in infants and preschool children, in health and disease
Session type: E-Communication Session
Number: 4319
Disease area: Paediatric lung diseases, Respiratory critical care

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
R. Mahmoud, H. Fischer, H. Proquitté, N. Fawethy, S. Hadhood, G. Schmalisch (Sohag, Egypt; Berlin, Germany). Relationship between endotracheal tube leakage and displayed tidal volume in neonatal ventilators. Eur Respir J 2009; 34: Suppl. 53, 4319

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Endotracheal tube leakages in ventilated neonates and their impact on tidal volume measurements
Source: Annual Congress 2010 - Ventilating the premature lung: current practice and outcomes
Year: 2010



The effect of mouth leak on tidal volume during non-invasive ventilation
Source: Annual Congress 2003 - Physiology of NIV: understanding the effects and chosing the best settings
Year: 2003


Lung de-recruitment and re-recruitment after suction of the endotracheal tube in ventilated children
Source: Annual Congress 2008 - Respiratory disorders in paediatric intensive care unit
Year: 2008


Tidal volume and leak measurements during nasopharyngeal CPAP in neonates
Source: Annual Congress 2009 - Neonatal respiratory disorders
Year: 2009

Limitation of lung collapse after endotracheal suctioning
Source: Eur Respir J 2002; 20: Suppl. 38, 449s
Year: 2002

Effect of deadspace reduction by the Kolobow tube on blood gases in small ventilated surfactant-depleted piglets
Source: Annual Congress 2009 - Respiratory disorders of the newborn
Year: 2009

The effect of dowsizing cannula diameter on tidal volume during ventilation
Source: Annual Congress 2004 - Noninvasive ventilatory support in acute and chronic respiratory failure
Year: 2004


Effect of tidal volume and nebuliser position on aerosol delivery during neonate ventilation
Source: Respiratory Failure and Mechanical Ventilation Conference 2020
Year: 2020



Increase in endotracheal tube (ETT) resistance after its use in ICU patients under mechanical ventilation (MV): forced oscillatory technique (FOT) evaluation
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007


Dynamic respiratory system mechanics in infants during pressure and volume controlled ventilation
Source: Eur Respir J 2001; 17: 115-121
Year: 2001



Relationship between peak inspiratory pressure and tidal volume during mechanical ventilation in ARDS
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

Automatic regulation of the cuff pressure in endotracheally-intubated patients
Source: Eur Respir J 2002; 20: 1010-1013
Year: 2002



Lung derecruitment related to endotracheal suction in ventilated preterm infants
Source: Annual Congress 2010 - Paediatric and neonatal intensive care
Year: 2010

Modelling the relationship between tidal volume and ventilation
Source: Eur Respir J 2007; 30: Suppl. 51, 324s
Year: 2007

Effect of manufacturer-inserted mask leaks on ventilator performance
Source: Eur Respir J 2010; 35: 627-636
Year: 2010



Influence of mask leak on applied volumes and pressures during simulated resuscitation of neonates
Source: Annual Congress 2011 - Resuscitation and ventilation in the baby and infant
Year: 2011

Leak compensation in positive pressure ventilators: a lung model study
Source: Eur Respir J 2001; 17: 259-267
Year: 2001



Influence of tidal volume on respiratory system impedance in mechanically ventilated patients
Source: Eur Respir J 2005; 26: Suppl. 49, 89s
Year: 2005

Role of continuous tracheal gas insufflation (c-TGI) with protective lung ventilation in respiratory acidosis
Source: Annual Congress 2008 - Acute lung injury and weaning
Year: 2008


Reliability of PEEP in neonatal resuscitation – comparison of two common ventilation devices
Source: Annual Congress 2008 - Neonatal intensive care: ventilation and beyond
Year: 2008