Open lung positive end-expiratory pressure (PEEP) titration by respiratory system input reactance (Xrs)

R. Dellaca‘, M. Andersson-Olerud, E. Zannin, P. Kostic, P. Pompilio, M. Romano‘, S. Bernardinello, A. Pedotti, P. Frykholm, G. Hedenstierna (Milano, Italy; Uppsala, Sweden)

Source: Annual Congress 2008 - Pathophysiology of acute lung injury
Session: Pathophysiology of acute lung injury
Session type: Oral Presentation
Number: 174
Disease area: Airway diseases, Respiratory critical care

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
R. Dellaca‘, M. Andersson-Olerud, E. Zannin, P. Kostic, P. Pompilio, M. Romano‘, S. Bernardinello, A. Pedotti, P. Frykholm, G. Hedenstierna (Milano, Italy; Uppsala, Sweden). Open lung positive end-expiratory pressure (PEEP) titration by respiratory system input reactance (Xrs). Eur Respir J 2008; 32: Suppl. 52, 174

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
LATE-BREAKING ABSTRACT: Automatic tailoring of positive end-expiratory pressure (PEEP) by forced oscillation technique (FOT) during non-invasive ventilation: Effects of posture and exertion in COPD
Source: Annual Congress 2012 - Advanced experience with long-term noninvasive ventilation and late-breaking abstracts
Year: 2012

Positive end-expiratory pressure and tidal volume titration after recruitment maneuver(RM) in ARDS--an animal study
Source: Eur Respir J 2004; 24: Suppl. 48, 265s
Year: 2004

Changes in respiratory system reactance (Xrs) during the first lung volume recruitment in preterm lambs on high frequency oscillatory ventilation (HFOV)
Source: Annual Congress 2012 - Issues in neonatal and paediatric intensive care
Year: 2012

Measurement of end-expiratory lung volume by a bag-in-box system during pressure support ventilation
Source: Eur Respir J 2005; 26: Suppl. 49, 89s
Year: 2005

Bi-level continuous positive airway pressure (CPAP)
Source: Annual Congress 2007 - Practical workshop: continuous positive airway pressure (CPAP)
Year: 2007


Mean, peak airway pressure and PEEP during mechanical ventilation
Source: Eur Respir J 2003; 22: Suppl. 45, 189s
Year: 2003

Auto continuous positive airway pressure (CPAP)
Source: Annual Congress 2007 - Practical workshop: continuous positive airway pressure (CPAP)
Year: 2007


Respiratory system impedance and end-expiratory pressure in ARDS under conventional frequencies of mechanical ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 601s
Year: 2002

Autotitrating external positive end-expiratory airway pressure to abolish expiratory flow limitation during tidal breathing in patients with severe COPD: a physiological study
Source: Eur Respir J, 56 (3) 1902234; 10.1183/13993003.02234-2019
Year: 2020



Continuous external negative pressure ventilation (CENPV) versus continuous positive pressure ventilation (CPPV) in intubated ARDS patients
Source: Eur Respir J 2002; 20: Suppl. 38, 200s
Year: 2002

Non-invasive Ventilation (NIV) for continuous positive airway pressure (CPAP) failure: does it work?
Source: International Congress 2017 – Noninvasive ventilation for acute respiratory failure
Year: 2017

A new method of non-invasive measurement of intrinsic PEEP (PEEPi)
Source: Annual Congress 2010 - News from noninvasive ventilation
Year: 2010


The relationship between maximal inspiratory pressure (MIP), peak inspiratory flow rate (PIF) and external inspiratory resistance (R) in health and COPD
Source: Annual Congress 2008 - Investigation, inspiration, ventilation, dedication: the essence of physiological measurement
Year: 2008

Comparative study of sincrony intermitent mandatory ventilation (SIMV) associated to pressure suport ventilation (PSV) versus non invasive positive pressure ventilation with bilevel (BIPAP®), as an alternative ventilatory weaning method for postoperat
Source: Eur Respir J 2004; 24: Suppl. 48, 696s
Year: 2004

Effects of PEEP on inspiratory resistance in mechanically ventilated COPD patients
Source: Eur Respir J 2001; 18: 491-498
Year: 2001



Increased pressure amplitude in mechanical ventilation leads to an increase in the breath condensate volume (BCV) to ventilation (Ve) ratio
Source: Eur Respir J 2001; 18: Suppl. 33, 481s
Year: 2001

Ventilator-induced lung injury
Source: Eur Respir Mon 2012; 55: 1-18
Year: 2012


Late-breaking abstract: Bi-level positive airway pressure (Bipap) effects on regional distribution of lung ventilation in COPD
Source: Annual Congress 2011 - Challenges in rehabilitation: some old dilemmas revisited with some solutions?
Year: 2011

The experience of autotitration of continuous positive airway pressure (CPAP)
Source: Eur Respir J 2004; 24: Suppl. 48, 569s
Year: 2004