Correction equation to compare exhaled nitric oxide measured by a portable analyzer to that obtained by the gold-standard device

S. Pizzimenti, E. Heffler, M. Bugiani, P. Piccioni, G. Guida, I. Badiu, S. Sciascia, G. Rolla (Torino, Italy)

Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Session: Clinical utility of exhaled nitric oxide measurement
Session type: Thematic Poster Session
Number: 1119
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
S. Pizzimenti, E. Heffler, M. Bugiani, P. Piccioni, G. Guida, I. Badiu, S. Sciascia, G. Rolla (Torino, Italy). Correction equation to compare exhaled nitric oxide measured by a portable analyzer to that obtained by the gold-standard device. Eur Respir J 2008; 32: Suppl. 52, 1119

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Comparison of fractional exhaled nitric oxide (FeNO) levels measurements between now portable analyzer and stationary analyzer
Source: Annual Congress 2010 - Biomarkers and Diagnosis of asthma and allergic respiratory diseases
Year: 2010

Reliability of a new portable device for the measurement of fractional exhaled nitric oxide (FeNO)
Source: Annual Congress 2010 - Innovations in the assessment of airway diseases
Year: 2010


Feasibility and repeatability of fractional exhaled nitric oxide (FENO) measurements using a new hand-held NO monitoring device in general practice
Source: Eur Respir J 2006; 28: Suppl. 50, 791s
Year: 2006

Intra-device repeatability of the NIOX-MINO handheld fractional exhaled nitric oxide monitor.
Source: International Congress 2019 – Asthma biomarkers, diagnostics and risk factors
Year: 2019


Exhaled nitric oxide measurement with portable analyser in COPD
Source: Eur Respir J 2007; 30: Suppl. 51, 366s
Year: 2007

Comparisons between portable and chemoluminescence exhaled nitric oxide measurements
Source: Eur Respir J 2008; 32: 243-244
Year: 2008


Reproducibility of exhaled nitric oxide (NO) measured by multiple exhalation flow technique (MEFT) in adults
Source: Eur Respir J 2003; 22: Suppl. 45, 279s
Year: 2003

A comparison of two analysers measuring exhaled nitric oxide concentration
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

Exhaled nitric oxide measured by a new hand-held device in clinical practice
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


Measurement of exhaled nitric oxide: comparison of 3 different analyzers
Source: International Congress 2018 – Biomarkers for evaluating asthma
Year: 2018

Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical analyzer and ecomedics chemoluminescence analyzer
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


Comparison of fractional exhaled nitric oxide (FeNO) levels measured by different analysers
Source: International Congress 2018 – Biomarkers for evaluating asthma
Year: 2018

The agreement between online and offline measurement of exhaled nitric oxide
Source: Eur Respir J 2001; 18: Suppl. 33, 39s
Year: 2001

Reproducibility of the Vivatmopro measurements for exhaled nitric oxide values
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


Effect of a sequential exhalation flow method on exhaled nitric oxide measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 340s
Year: 2004

Exhaled nitric oxide measured by using NIOX MINO and chemo-luminescence analyser: a comparative study
Source: Eur Respir J 2007; 30: Suppl. 51, 365s
Year: 2007

Comparison of exhaled nitric oxide values measured by two offline methods or NO breath
Source: Annual Congress 2013 –Systemic and airway biomarkers in respiratory diseases
Year: 2013


Agreement between a stationary device and a new hand held device for fractional exhaled nitric oxide (FENO) measurements in adults and children
Source: Eur Respir J 2004; 24: Suppl. 48, 163s
Year: 2004

Accuracy and repeatability of a hand-held nitric oxide analyzer in adults with respiratory symptoms
Source: Eur Respir J 2005; 26: Suppl. 49, 572s
Year: 2005

A different analysis applied to a mathematical model on output of exhaled nitric oxide
Source: Eur Respir J 2004; 24: Suppl. 48, 340s
Year: 2004