Unreliability of OSA diagnosis by cardio-respiratory monitoring (CRM)

F. Fanfulla, A. E. Taurino, N. D‘Artavilla Lupo, R. Trentin, R. Maestroni, C. Bruschi, C. Fracchia (Montescano, Italy)

Source: Annual Congress 2006 - Diagnosis of obstructive sleep apnoea (OSA)
Session: Diagnosis of obstructive sleep apnoea (OSA)
Session type: Thematic Poster Session
Number: 1168
Disease area: Sleep and breathing disorders

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
F. Fanfulla, A. E. Taurino, N. D‘Artavilla Lupo, R. Trentin, R. Maestroni, C. Bruschi, C. Fracchia (Montescano, Italy). Unreliability of OSA diagnosis by cardio-respiratory monitoring (CRM). Eur Respir J 2006; 28: Suppl. 50, 1168

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Usefulness of clinical and overnight oximetry (OO) parameters in the prediction of apnoea-hyponoea index (AHI) in Chinese patients with suspected obstructive sleep apnoea (OSA)
Source: Eur Respir J 2001; 18: Suppl. 33, 216s
Year: 2001

Capnographic measurement as a screening method for respiratory obstructive diseases
Source: International Congress 2015 – Monitoring airway diseases with lung function tests
Year: 2015


Clinical value of polymesam recording in diagnosis of obstructive sleep apnoea (OSA). Can we replace polysomnography (PSG) with polymesam (PM)?
Source: Eur Respir J 2001; 18: Suppl. 33, 91s
Year: 2001

Added value of a mandible movement automated analysis (MMAA) to a type 3 portable monitoring (PM) in the diagnosis of obstructive sleep apnea (OSA)
Source: Annual Congress 2011 - Physiology and diagnostic technology in obstructive sleep apnoea
Year: 2011

Reducing investigation time for the diagnosis of the obstructive sleep apnoea syndrome (OSAS) by combining oximetry with a screening algorithim
Source: Annual Congress 2011 - Obstructive sleep apnoea : physiology, diagnostic tools and technology
Year: 2011


Non-invasive ventilation (NIV) setup for COPD-OSA overlap syndrome: Is polysomnography (PSG) useful?
Source: International Congress 2016 – New insights into noninvasive ventilation: between the dream and reality
Year: 2016

Validation of a new polygraphy device for the diagnosis of obstructive sleep apnoea (OSA)
Source: Annual Congress 2011 - Physiology and diagnostic technology in obstructive sleep apnoea
Year: 2011

Reliability of the apnoea-hypopnoea index (AHI) reported by ventilator software in patients with obesity hypoventilation syndrome (OHS) treated with long-term noninvasive ventilation (NIV)
Source: Annual Congress 2013 –Long-term NIV: COPD, sleep, obesity and outcomes
Year: 2013


Automated analysis for the diagnosis of sleep apnoeas in patientes with suspected disease. Validity of a new respiratory polygraphy system
Source: International Congress 2019 – Diagnostic issues in obstructive sleep apnoea
Year: 2019


Acoustic respiratory monitoring (ARM) as an adjunct to polysomnography (PSG) in a sleep laboratory
Source: Annual Congress 2011 - Obstructive sleep apnoea : physiology, diagnostic tools and technology
Year: 2011


Ambulatory diagnosis of OSA and new technologies
Source: Eur Respir Mon 2010; 50: 136-149
Year: 2010


Telehome monitoring (THM) in COPD: A new model of evaluating nocturnal oxygen desaturation
Source: International Congress 2015 – Monitoring and phenotyping COPD
Year: 2015


Effect of short-term treatment with CPAP on cardiopulmonary exercise test (CPX) in patients with severe obstructive sleep apnea syndrome (OSAS)
Source: International Congress 2014 – Alterations of exercise and lung function in different diseases
Year: 2014


Validity of a supersimplified device for diagnosis of patients with suspected obstructive sleep apnoea-hypopnoea (OSAH). Preliminary results
Source: Annual Congress 2009 - Diagnostic aspects in obstructive sleep apnoea
Year: 2009


Should patients with possible obstructive sleep apnoea (OSA) be screened with overnight pulse oximetry or multichannel sleep studies as a first line diagnostic tool?
Source: International Congress 2015 – Measuring sleep-disordered breathing in children and adults II: questionnaires, epidemiology and sleep studies
Year: 2015


PAP telemonitoring and residual apnea–hypopnea index/symptoms: clinical cases and impact for follow-up management
Source: Virtual Congress 2021 – Respiratory sleep
Year: 2021


Reliability of automatic (Auto-CPAP) pressure titration in patients with obstructive sleep apnoea (OSA)
Source: Eur Respir J 2001; 18: Suppl. 33, 417s
Year: 2001

Predictive value of clinical, oximetry and cephalometric parameters in the diagnosis of sleep apnea syndrome
Source: Eur Respir J 2002; 20: Suppl. 38, 451s
Year: 2002

Validation of five non-invasive respiratory rate monitors in patients with COPD in a laboratory setting
Source: International Congress 2015 – Clinical assessment in asthma and COPD
Year: 2015

Constant versus automatic continuous positive airway pressure therapy for obstructive sleep apnoea: in-lab and home evaluation
Source: Eur Respir J 2001; 18: Suppl. 33, 15s
Year: 2001