Stroke volume at rest and during exercise in upright and supine position measured by acetylene uptake in healthy controls

H. Groepenhoff, S. Holverda, A. Boonstra, P. E. Postmus, A. Vonk-Noordegraaf (Amsterdam, Netherlands)

Source: Annual Congress 2006 - Landmark developments in lung function testing: 2006
Session: Landmark developments in lung function testing: 2006
Session type: Oral Presentation
Number: 979

Congress or journal article abstractSlide presentation

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
H. Groepenhoff, S. Holverda, A. Boonstra, P. E. Postmus, A. Vonk-Noordegraaf (Amsterdam, Netherlands). Stroke volume at rest and during exercise in upright and supine position measured by acetylene uptake in healthy controls. Eur Respir J 2006; 28: Suppl. 50, 979

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Right heart catheterization hemodynamics at rest and exercise in supine versus upright position with focus on pulmonary hypertension
Source: International Congress 2019 – Pulmonary arterial hypertension: recent advances from the bedside
Year: 2019

Pulmonary arterial pressure at rest and during exercise in normal controls
Source: Annual Congress 2008 - Pulmonary vascular medicine
Year: 2008

Cardiopulmonary exercise test unveils abnormal exercise physiology in patients affected by pulmonary arterial hypertension with a low-risk profile 6 minute walk distance.
Source: Virtual Congress 2020 – Exercise and haemodynamics in pulmonary hypertension
Year: 2020


Measurement of pulmonary gas-exchange function at rest and during exercise
Source: Annual Congress 2007 - PG2 - Respiratory physiology: pulmonary gas transfer and arterial blood gases
Year: 2007



Maximal cardiopulmonary exercise testing in mildly symptomatic patients with idiopathic pulmonary arterial hypertension: correlations with 6-min walk distance and resting hemodynamics
Source: Annual Congress 2009 - Pulmonary vascular diseases
Year: 2009

Lower arterial oxygen partial pressure and saturation during treadmill compared to cycle exercise in COPD
Source: Annual Congress 2010 - Gas exchange and paediatric exercise testing
Year: 2010

Pursed lip breathing reduced dynamic hyperinflation, improving exercise tolerance and arterial oxygenation in COPD patients undergoing submaximal intensity exercise
Source: Annual Congress 2010 - Mucous clearance and treatment modalities in respiratory physiotherapy
Year: 2010


Mean pulmonary artery pressure-heart rate (mPAP-HR) relationship during submaximal supine exercise in idiopathic pulmonary arterial hypertension (iPAH)
Source: Annual Congress 2005 - Exercise in pulmonary hypertension
Year: 2005


ACE-inhibition improves peak exercise oxygen uptake and ventilation in COPD: an effect unrelated to pulmonary function
Source: Eur Respir J 2003; 22: Suppl. 45, 205s
Year: 2003

Stroke volume reflects changes in six minute walk test during follow-up in pulmonary arterial hypertension
Source: Annual Congress 2009 - Pulmonary circulation I
Year: 2009

Systolic blood pressure response to the incremental shuttle walking test in pulmonary hypertension
Source: Annual Congress 2005 - Exercise in pulmonary hypertension
Year: 2005


Oxygen kinetics during submaximal cardiopulmonary exercise testing (CPET) in adult patients with cystic fibrosis is related to maximal exercise breathing pattern
Source: Annual Congress 2009 - Cystic fibrosis: advances in clinical research
Year: 2009


Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest
Source: Eur Respir J 2001; 17: 1120-1127
Year: 2001



Comparison of cycle ergometer CPET in upright position and during right heart catheterization in 45°-position in patients with PAH
Source: Annual Congress 2007 - Mechanisms of exercise intolerance in cardiorespiratory disease
Year: 2007


Age-related upper limits of normal for maximum upright exercise pulmonary haemodynamics
Source: Eur Respir J 2016; 47: 1179-1188
Year: 2016



Resistive or dynamic exercise stress testing of the pulmonary circulation and the right heart
Source: Eur Respir J, 50 (1) 1700151; 10.1183/13993003.00151-2017
Year: 2017



Resting DLCO predictis exercise lung gas exchange efficiency but not walking distance at 6‘WT in idiopathic pulmonary artery hypertension (IPAH)
Source: Eur Respir J 2005; 26: Suppl. 49, 106s
Year: 2005

The measured vs. estimated oxygen uptake from treadmill exercise testing in patients with chronic pulmonary diseases
Source: International Congress 2019 – Cardiopulmonary exercise testing
Year: 2019

The prevalence of ventilatory limitation at peak exercise in pulmonary arterial hypertension
Source: International Congress 2014 – Alterations of exercise and lung function in different diseases
Year: 2014

Physiological response to the six-minute walk test in pulmonary arterial hypertension
Source: Eur Respir J 2005; 26: 667-672
Year: 2005