e-learning
resources
Virtual 2021
07.09.2021
New insights into lung function testing
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
Validation of manual and automated wheezing detection from audio recordings
S. Sarraf (Melbourne [Vic], Australia), R. Platt (Calgary [AB], Canada), K. Chan (Leichhardt [NSW], Australia), N. Skjodt (Lethbridge [AB], Canada)
Source:
Virtual Congress 2021 – New insights into lung function testing
Session:
New insights into lung function testing
Session type:
E-poster
Number:
3221
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
S. Sarraf (Melbourne [Vic], Australia), R. Platt (Calgary [AB], Canada), K. Chan (Leichhardt [NSW], Australia), N. Skjodt (Lethbridge [AB], Canada). Validation of manual and automated wheezing detection from audio recordings. 3221
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Panel discussion: What’s NEW in the 2022 ERS/ATS PFT Interpretation Statement
Late Breaking Abstract - Accuracy of artificial intelligence in detecting pathological breath sounds in children using digital stethoscopes
Clinical profile of Tropical Pulmonary Eosinophilia (TPE) in Bihar, India
Related content which might interest you:
Comparison of visual and automatic methods for scoring leg movements in polygraphic sleep recordings. Validity of a modified automatic method
Source: Annual Congress 2008 - Diagnostic aspects of sleep apnoea
Year: 2008
Evaluation of a simplified sleep recording and analyzing device at the bedside
Source: Annual Congress 2008 - Diagnostic aspects of sleep apnoea
Year: 2008
Automated detection of cough events with a Smartphone
Source: Virtual Congress 2021 – Management of chronic cough and obstructive diseases
Year: 2021
Performance of a digital signal processing algorithm for the accurate quantification of cough frequency
Source: Eur Respir J, 58 (2) 2004271; 10.1183/13993003.04271-2020
Year: 2021
High accuracy of automated respiratory rate readings in a novel, non-contact home monitor
Source: Virtual Congress 2021 – New insights into lung function testing
Year: 2021
An algorithm to automatically identify cough sounds from clinical recordings
Source: Annual Congress 2003 - Cough and sleep disorders
Year: 2003
Validation of assisted automated scoring versus manual scoring of polysmnography (PSG) studies
Source: International Congress 2017 – Diagnostic approaches to obstructive sleep apnoea
Year: 2017
Automated identification of asthma patients within an electronical medical record database using machine learning
Source: Annual Congress 2012 - Paediatric respiratory epidemiology. Wheeze: where, how and why?
Year: 2012
A comparison of automated and manual sleep staging and respiratory event recognition in a portable sleep diagnostic device with in-lab sleep study
Source: Virtual Congress 2020 – Screening methods and diagnostic tools for obstructive sleep apnoea
Year: 2020
A new digital stethophone: bioacoustic analyses of breath sounds recorded from a simple mp3 player
Source: Annual Congress 2007 - Advances in respiratory mechanics
Year: 2007
Role of automatic computerized cough analyzer in the assessment of chronic cough
Source: Eur Respir J 2007; 30: Suppl. 51, 364s
Year: 2007
Standardization of computerized respiratory sound analysis
Source: Guideline 2000
Year: 2000
Automatic wheezing detection for asthmathic children
Source: Eur Respir J 2004; 24: Suppl. 48, 614s
Year: 2004
Evaluation of a novel device for automatic detection of nocturnal cough in asthmatic children – preliminary results
Source: Annual Congress 2007 - Assessing asthma severity and control in children
Year: 2007
Usefulness of symbolic dynamics to characterize oximetric recordings from a smartphone in the detection of pediatric sleep apnea
Source: International Congress 2018 – Assessing pathophysiology in children
Year: 2018
Manual vs. automated analysis of polysomnographic recordings in patients with COPD
Source: Annual Congress 2011 - Physiology and diagnostic technology in obstructive sleep apnoea
Year: 2011
Automatic wheezing-episode detector using spectrogram analysis of breath sounds
Source: Eur Respir J 2003; 22: Suppl. 45, 446s
Year: 2003
Validation of a (semi)-automatic measurement- and control platform for centralized, simultaneous electronic nose (eNose) analyses in multi-centre trials
Source: Annual Congress 2011 - Phenotyping and monitoring of airway diseases
Year: 2011
The concordance of manual (visual) scoring and automatic analysis in sleep staging
Source: Annual Congress 2008 - Diagnostic aspects of sleep apnoea
Year: 2008
Automatic detection of sleep-disordered breathing from a single-channel airflow record
Source: Eur Respir J 2007; 29: 728-736
Year: 2007
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept