Endobronchial valves for emphysema are effective in patients with moderate hyperinflation in the presence of a clear target lobe

K. Klooster (Groningen, Netherlands), J. Hartman (Groningen, Netherlands), D. Slebos (Groningen, Netherlands)

Source: Virtual Congress 2020 – Interventional pulmonology: the pleura and bronchoscopic treatment of emphysema
Session: Interventional pulmonology: the pleura and bronchoscopic treatment of emphysema
Session type: E-poster session
Number: 875

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
K. Klooster (Groningen, Netherlands), J. Hartman (Groningen, Netherlands), D. Slebos (Groningen, Netherlands). Endobronchial valves for emphysema are effective in patients with moderate hyperinflation in the presence of a clear target lobe. 875

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Intrabronchial valve treatment in patients with severe heterogeneous emphysema and intact interlobar fissures
Source: International Congress 2015 – Bronchoscopic treatment of COPD and asthma: valves, coils, thermoplastics and something more
Year: 2015


The minimal important difference for target lobe volume reduction following endoscopic valve therapy in patients with advanced emphysema
Source: International Congress 2016 – Endoscopic lung volume reduction II
Year: 2016


Ability for dynamic hyperinflation increases after bronchoscopic lung volume reduction in patients with severe emphysema.
Source: International Congress 2017 – Endoscopic lung volume reduction (EVLR) and targeted lung denervation (TLD)
Year: 2017

Endobronchial valve placement impact on breathing pattern during exercise in patients with severe emphysema
Source: International Congress 2019 – Exercise physiopathology in various respiratory diseases
Year: 2019




Bronchoscopic lung volume reduction with endobronchial valves for patients with heterogeneous emphysema and intact interlobar fissures (BeLieVeR-HIFi)
Source: International Congress 2014 – Bronchoscopic treatment of emphysema: where are we?
Year: 2014


Bronchoscopic lung volume reduction with coils (BLVR-Coils) for treatment of patients with severe heterogeneous emphysema and bilaterally incomplete fissures. Its effectiveness in everyday endoscopic practice
Source: Annual Congress 2013 –Bronchoscopic treatment of COPD and asthma: where are we going?
Year: 2013


The minimal important difference for residual volume in patients with severe emphysema
Source: Eur Respir J 2012; 40: 1137-1141
Year: 2012



Radiological and clinical outcomes of using Chartis™ to plan endobronchial valve treatment
Source: Eur Respir J 2013; 41: 302-308
Year: 2013



Bronchoscopic lung volume reduction with endobronchial valves improves exercise capacity but not oxygen uptake kinetics in a group of patients with severe emphysema
Source: Annual Congress 2013 –Mechanisms contributing to exercise limitation in health and respiratory, cardiac and pulmonary vascular diseases
Year: 2013

CT assessment of lobar heterogenity and fissure integrity in pulmonary emphysema for bronchoscopic lung volume reduction with valve
Source: International Congress 2015 – A morphological view of chest pathology
Year: 2015


Endobronchial microbiological colonisation in stable COPD patients with severe emphysema undergoing endoscopic lung volume reduction.
Source: International Congress 2017 – Highlights on clinical problems in COPD
Year: 2017

Endobronchial valves for severe emphysema
Source: Eur Respir Rev, 28 (152) 180121; 10.1183/16000617.0121-2018
Year: 2019



Endobronchial valve treatment of terminal emphysema patients with high heterogeneity score
Source: Annual Congress 2010 - New toys, old problems: extrapleural lung volume reduction, sedation and comfort in bronchoscopy
Year: 2010


Bronchoscopic lung volume reduction interventions for severe emphysema
Source: International Congress 2016 – Vitamin D and asthma prevention, COPD screening, and bronchoscopic lung volume reduction in emphysema
Year: 2016


Unilateral bronchoscopic volume reduction with valve implants in patients with severe emphysema
Source: Eur Respir J 2003; 22: Suppl. 45, 206s
Year: 2003

Bronchial valve treatment of emphysema, collateral ventilation, and contrast to surgery for emphysema
Source: Eur Respir J 2007; 30: Suppl. 51, 106s
Year: 2007

BODE index improves after endobronchial valve treatment in patients with emphysema without interlobar collateral ventilation
Source: International Congress 2016 – Bronchoscopy: from diagnostic to treating air leaks
Year: 2016

Endoscopic lung volume reduction with endobronchial valves in very low DLCO patients
Source: Virtual Congress 2020 – The hot and cold of interventional pulmonology
Year: 2020




Efficacy predictors of lung volume reduction with Zephyr valves in a European cohort
Source: Eur Respir J 2012; 39: 1334-1342
Year: 2012



Unilateral lung volume reduction surgery in patients with homogenous distribution of pulmonary emphysema
Source: Eur Respir J 2005; 26: Suppl. 49, 491s
Year: 2005