Antistatic treatment and the amount of salbutamol actuated have variable effect on drug delivery of six different valved holding chambers (VHC)

P. Csonka (Tampere, Finland), L. Lehtimäki (Tampere, Finland)

Source: International Congress 2019 – Severe acute asthma and troublesome wheezing
Session: Severe acute asthma and troublesome wheezing
Session type: Thematic Poster
Number: 961
Disease area: Airway diseases, Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
P. Csonka (Tampere, Finland), L. Lehtimäki (Tampere, Finland). Antistatic treatment and the amount of salbutamol actuated have variable effect on drug delivery of six different valved holding chambers (VHC). 961

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Priming of a non-conducting valved holding chamber (VHC) is formulation dependent and may result in inconsistent medication delivery
Source: Annual Congress 2007 - Miscellaneous pulmonary pharmacology
Year: 2007


Impact of inspiratory delay and valved holding chamber (VHC) material on drug delivery
Source: Eur Respir J 2001; 18: Suppl. 33, 494s
Year: 2001

Delivery of medication via a novel non-electrostatic valved holding chamber (VHC) for infant use depends on the number of inhalations
Source: Eur Respir J 2006; 28: Suppl. 50, 713s
Year: 2006

Comparison of two valved holding chambers for the delivery of an HFA-based solution corticosteroid formulation
Source: Eur Respir J 2002; 20: Suppl. 38, 500s
Year: 2002

In vitro delivery of an HFA-based corticosteroid by pediatric and adult valved holding chambers (VHC): effect of inhalation flow rate
Source: Eur Respir J 2002; 20: Suppl. 38, 500s
Year: 2002

A small volume valved holding chamber (VHC) manufactured from charge dissipative materials has comparable in vitro performance with a large volume non-conducting plastic spacer for both bronchodilator and anti-inflammatory formulations
Source: Eur Respir J 2005; 26: Suppl. 49, 340s
Year: 2005

Not all antistatic valved holding chambers have equivalent performance: An example why each valved holding chamber (VHC)-inhaler combination should be considered unique
Source: Annual Congress 2012 - The best of pharmacology treatments of airway diseases: new devices and drugs
Year: 2012


Valved holding chamber drug delivery is dependent on breathing pattern and device design
Source: ERJ Open Res, 5 (1) 00158-2018; 10.1183/23120541.00158-2018
Year: 2019



In vitro equivalence exists for infant non-conducting (NC) and anti-static (AS) valved holding chambers (VHC) from the same family of add on devices used with pressurized metered dose inhalers (pMDIs) provided pre-conditioning of the non-conducting VHCs is undertaken
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010


In vitro comparison of the effect of inhalation delay on the variability of the delivered dose from valved holding chambers
Source: Annual Congress 2012 - Assessing and treating childhood asthma and allergy
Year: 2012


Laboratory assessment of drug delivery of Beclomethasone/Formoterol metered dose inhaler (MDI) with a new valved holding chamber (VHC) designed specifically for 'on-the-go' use.
Source: Virtual Congress 2021 – Therapies for respiratory diseases in primary care and COVID - 19
Year: 2021


Valved holding chamber (VHC) angle can affect pressurized netered-dose inhaler (pMDI) medication delivery efficiency
Source: International Congress 2018 – Determinants and monitoring of asthma control
Year: 2018




New anti-static youth valved holding chamber (VHC) can be used out-of-package and deliver β2-agonist medication effectively
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009


Novel non-electrostatic valved holding chamber (VHC) has comparable in vitro performance for delivery of beta-2 agonist as similar-sized, pre-washed but non-conducting VHC
Source: Eur Respir J 2006; 28: Suppl. 50, 211s
Year: 2006

The impact of different valved holding chambers (VHCs) on lung drug delivery: using functional respiratory imaging (FRI) and a single metered dose inhaler (MDI) type
Source: Virtual Congress 2020 – Diagnosis and management of airways disease in primary care
Year: 2020




Breath-by-breath delivered dose comparison from three anti-static valved holding chambers with facemasks under simulated pediatric breathing conditions
Source: Annual Congress 2011 - Treating childhood asthma
Year: 2011

A visual indicator for inhalation from a valved holding chamber (VHC) is an aid in delivery of inhaled medication to infants and small children via facemask
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009


In vitro testing of an improved collapsible valved holding chamber (CHC) with a pressurized metered-dose inhaler delivered bronchodilator, simulating an adult mechanically ventilated patient
Source: Annual Congress 2010 - Treatment options for asthma
Year: 2010


Patient centered development of a new valved holding chamber (VHC) designed specifically for on-the-go use
Source: Virtual Congress 2020 – Asthma inhalers: devices and adherence studies
Year: 2020


Impact of inhalation delay on medication delivery from a salbutamol HFA pressurized metered dose inhaler used with and without a new prototype portable valved holding chamber
Source: International Congress 2019 – COPD treatment: clinical trials, cohorts and inhaler device studies
Year: 2019