e-learning
resources
Berlin 2001
Tuesday 25.09.2001
News in inhalation therapy and devices in childhood asthma
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
In vitro
testing of inhalation devices with face masks
K. Nikander, E. Berg, L. Morra, G. C. Smaldone (Lund, Sweden; New York, United States Of America)
Source:
Annual Congress 2001 - News in inhalation therapy and devices in childhood asthma
Session:
News in inhalation therapy and devices in childhood asthma
Session type:
Poster Discussion
Number:
3297
Disease area:
Airway diseases, Paediatric lung diseases
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
K. Nikander, E. Berg, L. Morra, G. C. Smaldone (Lund, Sweden; New York, United States Of America).
In vitro
testing of inhalation devices with face masks. Eur Respir J 2001; 16: Suppl. 31, 3297
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Late Breaking Abstract - Implications of treatable traits and treatment choices on exacerbation risk in moderate-severe asthma
Management of Severe Asthma in Pediatric Patients by an Interdisciplinary Team in a Public Hospital Setting.
Respiratory sequelae of preterm birth across the life span
Related content which might interest you:
In-vitro performance of two valved holding chambers (VHCs)/Spacers for paediatric use tested with facemasks attached is unaffected by routine use and cleaning
Source: Annual Congress 2008 - Wheezing in preschool children
Year: 2008
Drug delivery from inhalation devices is dependent on face mask seal and the child's breathing pattern
Source: Eur Respir J 2001; 18: Suppl. 33, 493s
Year: 2001
Feasibility of three-dimensional facial imaging and printing for producing customised nasal masks for continuous positive airway pressure
Source: ERJ Open Res, 7 (1) 00632-2020; 10.1183/23120541.00632-2020
Year: 2021
In vitro performance of the prodose AAD® handheld - a new portable aerosol delivery system
Source: Eur Respir J 2004; 24: Suppl. 48, 581s
Year: 2004
Breath-by-breath delivered dose comparison from three anti-static valved holding chambers with facemasks under simulated pediatric breathing conditions
Source: Annual Congress 2011 - Treating childhood asthma
Year: 2011
A visual indicator for inhalation from a valved holding chamber (VHC) is an aid in delivery of inhaled medication to infants and small children via facemask
Source: Annual Congress 2009 - New aspects of inhalation therapy
Year: 2009
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Source: Eur Respir J 2004; 23: 129-135
Year: 2004
Measuring patient compliance in inhalation studies by smart card technology
Source: Annual Congress 2007 - Cystic fibrosis lung disease: what do we measure? What do we know?
Year: 2007
The amount of intentional leaks in masks significantly impacts on bi-level non-invasive ventilation efficacy: a bench test study
Source: Annual Congress 2007 - Technological progress in noninvasive ventilation
Year: 2007
Analysis of making mistakes in using of inhalation devices in asthma treatment
Source: Annual Congress 2008 - Asthma control or asthma severity
Year: 2008
Comparison of aerosol delivery from two inhaler technique-guidance devices.
Source: International Congress 2018 – Airway disease: recent discoveries
Year: 2018
In vitro evaluation of aerosolized delivery of various medications during mechanical ventilation
Source: International Congress 2017 – Pulmonary drug and devices delivery
Year: 2017
Evaluation of delivered dose and treatment time of several mesh nebulizers under in vitro simulated use
Source: International Congress 2017 – Inhalers and their use
Year: 2017
Specific inhalation challenges to metal working fluids
Source: Annual Congress 2012 - Respiratory diseases at at work: epidemiology, inflammation and challenge studies
Year: 2012
Is it necessary to use a nose clip in the performance of spirometry?
Source: Eur Respir J 2004; 24: Suppl. 48, 182s
Year: 2004
In vitro
delivery of an HFA-based corticosteroid by pediatric and adult valved holding chambers (VHC): effect of inhalation flow rate
Source: Eur Respir J 2002; 20: Suppl. 38, 500s
Year: 2002
Validation and clinical application of a newly developed high-concentration oxygen-delivery device with a jet nebulizer function
Source: Annual Congress 2010 - COPD: management
Year: 2010
In vitro validation of nitrogen multiple breath washout using ultrasonic equipment
Source: Annual Congress 2011 - Advances in lung function testing from infancy to adulthood
Year: 2011
In vitro comparison of emitted dose with 2 types of nebulizers during non invasive ventilation
Source: Annual Congress 2012 - New insights in the physical assessment and therapy of respiratory patients
Year: 2012
Assessment of facemask seal leakage from six VHC systems on two pediatric simulated anatomical models under simulated breathing conditions
Source: Annual Congress 2012 - Assessing and treating childhood asthma and allergy
Year: 2012
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept