Tremormetry with a laser pointer; normal values and reproducibility

T. Nizet, M. Broeders, H. Folgering (Groesbeek, The Netherlands)

Source: Annual Congress 2001 - Clinical asthma: miscellaneous
Session: Clinical asthma: miscellaneous
Session type: Thematic Poster Session
Number: 2877
Disease area: Airway diseases, Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
T. Nizet, M. Broeders, H. Folgering (Groesbeek, The Netherlands). Tremormetry with a laser pointer; normal values and reproducibility. Eur Respir J 2001; 16: Suppl. 31, 2877

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Use of a contactless optical device (Structured Light Plethysmography (SLP)) to quantify and record breathing parameters.
Source: International Congress 2017 – Discussion of techniques and technologies in lung function
Year: 2017

Workstation 2 – Spirometry: performing the test, safety measures, selecting the best values and simulating errors
Source: International Congress 2014 – EW9 Spirometry knowledge and basic skills (European spirometry training programme)
Year: 2014

Workstation 2 – Spirometry: performing the test, safety measures, selecting the best values and simulating errors
Source: International Congress 2014 – EW8 Spirometry knowledge and basic skills (European spirometry training programme)
Year: 2014

Diagnostic value of selected parameters obtained from impulse oscillometry measurements in children
Source: Eur Respir J 2005; 26: Suppl. 49, 119s
Year: 2005

Radial probe endobronchial ultrasound and needle-based confocal laser endomicroscopy
Source: Virtual Congress 2020 – Bronchoscopy and endosonography: Lung cancer
Year: 2020

Forced oscillation technique (FOT) reference values: Does one size fit all?
Source: Annual Congress 2012 - Predicting the future: the impact of reference values on a range of respiratory paramaters
Year: 2012


Workstation 2 - Spirometry: performing the test, safety measures, selecting the best values and simulating errors
Source: International Congress 2014 – EW7 Spirometry knowledge and basic skills (European spirometry training programme)
Year: 2014

Accuracy of a portable system for DLCO measurement using ultrasonic flow and molar mass measurement
Source: Eur Respir J 2006; 28: Suppl. 50, 422s
Year: 2006

Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer
Source: Eur Respir J 2004; 23: 763-768
Year: 2004



Reproducibility and agreement of lung function parameters using portable and stationary spirometers
Source: Annual Congress 2008 - Quality spirometry: the only spirometry!
Year: 2008


Inter-laboratory variability in the measurement of lung function - contribution of volume calibration errors
Source: Eur Respir J 2004; 24: Suppl. 48, 183s
Year: 2004

Correction of measurement error in a commercial multiple-breath washout device
Source: Virtual Congress 2021 – Respiratory physiology and breathing during sleep in health and sickness
Year: 2021


Evaluating the accuracy of pulse oximetry: Finger probe versus earlobe probe in patients with confirmed or suspected COVID-19 within the community setting.
Source: Virtual Congress 2021 – Diagnosis and management of COVID-19
Year: 2021


Combination of the narrow band imaging (NBI) and autofluorescence videobronchoscopy (AFI) improves assessment of central lung cancer extension
Source: Annual Congress 2010 - Tissue is mostly the issue: diagnostic and therapeutic bronchoscopy
Year: 2010


Calibration of a (semi)-automatic measurement and control platform for centralized, simultaneous electronic nose (eNose) analyses in multi-centre trials
Source: Annual Congress 2012 - Exhaled biomarkers to assess airway inflammation
Year: 2012



In vivo size and shape measurement of the upper airway using endoscopic optical coherence tomography (OCT)
Source: Eur Respir J 2004; 24: Suppl. 48, 445s
Year: 2004

Feasibility and reliability of ulna length measurements in calculating predicted lung function values in children
Source: Eur Respir J 2005; 26: Suppl. 49, 180s
Year: 2005

Comparison of an ultrasonic spirometer against a fully calibrated and quality assured pneumotachograph system over a one month period
Source: Eur Respir J 2006; 28: Suppl. 50, 279s
Year: 2006

Workstation 4 - Calibration and quality control - how to calibrate different devices and perform biological control procedures
Source: Annual Congress 2013 –Educational skills workshop 7: Spirometry knowledge and basic skills (European spirometry training programme)
Year: 2013