Standardisation and application of the single-breath determination of nitric oxide uptake in the lung

Gerald S. Zavorsky, Connie C.W. Hsia, J. Michael B. Hughes, Colin D.R. Borland, Hervé Guénard, Ivo van der Lee, Irene Steenbruggen, Robert Naeije, Jiguo Cao, Anh Tuan Dinh-Xuan

Source: Eur Respir J , 49 (2) 1600962; DOI: 10.1183/13993003.00962-2016
Journal Issue: February

Congress or journal article abstractFull text journal articlePDF journal article, handout or slidesCME test or case report

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Gerald S. Zavorsky, Connie C.W. Hsia, J. Michael B. Hughes, Colin D.R. Borland, Hervé Guénard, Ivo van der Lee, Irene Steenbruggen, Robert Naeije, Jiguo Cao, Anh Tuan Dinh-Xuan. Standardisation and application of the single-breath determination of nitric oxide uptake in the lung. Eur Respir J , 49 (2) 1600962; DOI: 10.1183/13993003.00962-2016

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Standardization of pulmonary diffusing capacity for nitric oxide
Source: International Congress 2017 – ERS statements and technical standards on diagnosis and monitoring
Year: 2017


Effect of a sequential exhalation flow method on exhaled nitric oxide measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 340s
Year: 2004

Early detection of emphysema with the nitric oxide diffusion capacity
Source: Eur Respir J 2007; 30: Suppl. 51, 8s
Year: 2007

A small amount of inhaled nitric oxide does not increase lung diffusing capacity
Source: Eur Respir J 2006; 27: 1251-1257
Year: 2006



A comparison of two analysers measuring exhaled nitric oxide concentration
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

Reference value formula for the single-breath diffusion capacity of the lung using nitric oxide (DLNO)
Source: Annual Congress 2009 - Accuracy in lung function testing
Year: 2009

Standardization of the two compartment model for the partitioning of exhaled NO: Effect of different flows and breath-hold periods
Source: Annual Congress 2013 –Assessment of airway inflammation by exhaled gases
Year: 2013


ERJ February Podcast: ERS technical standards for the single-breath determination of nitric oxide uptake in the lung
Source: Eur Respir J , 49 (2) 17E4902; DOI: 10.1183/13993003.E4902-2017
Year: 2017

Diagnostic use of exhaled nitric oxide (eNO) after lung transplantation
Source: Eur Respir J 2006; 28: Suppl. 50, 723s
Year: 2006

Novel method of measuring exhaled nitric oxide and carbon monoxide at several exhalation flow rates in normal and asthmatic subjects
Source: Eur Respir J 2001; 18: Suppl. 33, 463s
Year: 2001

Extended measurement of exhaled nitric oxide in patients after lung transplantation
Source: Eur Respir J 2005; 26: Suppl. 49, 705s
Year: 2005

Assessment of exhaled breath condensate contamination during measurement of nitric oxide metabolites
Source: International Congress 2015 – Exhaled biomarkers in monitoring airways disease
Year: 2015

Reproducibility of the Vivatmopro measurements for exhaled nitric oxide values
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


Diffusing capacity of the lung for nitric oxide and carbon monoxide: Influence of alveolar volume
Source: Annual Congress 2010 - Advances in lung function I
Year: 2010

Investigation on the effectiveness of the Mostgraph and fractional exhaled nitric oxide measurement in chronic cough
Source: Annual Congress 2012 - Exhaled biomarkers in airway diseases
Year: 2012


Inter-instrument variability in exhaled nitric oxide measurement and implications on test interpretation
Source: International Congress 2014 – Airway biomarkers
Year: 2014

Exhaled nitric oxide values measured at 10ml/s influence assessments of bronchial nitric oxide flux
Source: Eur Respir J 2006; 28: Suppl. 50, 792s
Year: 2006

Comparison of exhaled nitric oxide values measured by two offline methods or NO breath
Source: Annual Congress 2013 –Systemic and airway biomarkers in respiratory diseases
Year: 2013


Reduced bronchial nitric oxide flux but unchanged alveolar nitric oxide concentration after exposure to hyperbaric hyperoxia
Source: Annual Congress 2010 - New diagnostic approaches in respiratory function
Year: 2010