Evaluation of bronchodilator response in healthy subjects using pulmonary function test and impulse oscillometry system

Yukiko Matsuura (chiba, Japan), Yukiko Matsuura, Naoko Kawata, Yoriko Iesato, Ken Iesato, Kazutoshi Sugiura, Jun Ikari, Yuji Tada, Koichiro Tatsumi

Source: International Congress 2016 – Lung function and imaging: new findings and new approaches
Session: Lung function and imaging: new findings and new approaches
Session type: Thematic Poster
Number: 2238
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Yukiko Matsuura (chiba, Japan), Yukiko Matsuura, Naoko Kawata, Yoriko Iesato, Ken Iesato, Kazutoshi Sugiura, Jun Ikari, Yuji Tada, Koichiro Tatsumi. Evaluation of bronchodilator response in healthy subjects using pulmonary function test and impulse oscillometry system. Eur Respir J 2016; 48: Suppl. 60, 2238

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Impulse oscillometry parameters variability and response to bronchodilator in healthy adults
Source: International Congress 2017 – Lung function testing
Year: 2017

Pulmonary function test and impulse oscillometry in severe COPD patients‘ offspring
Source: Annual Congress 2008 - Assessment of the respiratory system
Year: 2008


Small airway dysfunction by impulse oscillometry system (IOS) in asthma. Relationship with spirometry, bronchodilator response and disease control
Source: Annual Congress 2012 - Lung function tests in monitoring airway diseases
Year: 2012

Normal range for bronchodilation response in impulse oscillometry parameters in healthy adults
Source: Virtual Congress 2020 – Lung function tests and exhaled biomarkers
Year: 2020


Impulse oscillometry provides an effective measure of bronchodilator responses in patients with COPD
Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing
Year: 2008


Impulse oscillometry parameters in assessment of responses to metacholine challenge test
Source: Eur Respir J 2005; 26: Suppl. 49, 119s
Year: 2005

Comparison of sensitivity of impulse oscillometry, plethysmography and spirometry for measuring bronchodilation in asthma
Source: Eur Respir J 2003; 22: Suppl. 45, 100s
Year: 2003

Detection of bronchial asthma using impulse oscillation system (IOS) in patients with normal spirometry
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

Using of impulse oscillometry in bronchodilatation response evaluation in patients with chronic cough
Source: Annual Congress 2008 - Lung function, airways and cough
Year: 2008


Utility of impulse oscillometry in prediction of annual decline of pulmonary function in patients with COPD
Source: Eur Respir J 2004; 24: Suppl. 48, 59s
Year: 2004

Bronchodilator response in healthy adults assessed with the forced oscillation technique and spirometry
Source: Annual Congress 2009 - New data on respiratory function - from experimental approaches to man
Year: 2009

Repeatability and bronchodilator response using impulse oscillation system (IOS) in children
Source: Annual Congress 2009 - Paediatric lung function, imaging and methodology in health and disease
Year: 2009


Airway resistance during the methacholine challenge test: Comparison between impulse oscillometry and plethysmographic technique
Source: Annual Congress 2011 - Lung and airway function
Year: 2011

Agreement of airway resistance measurements by two different techniques of body-plethysmography and impulse oscillometry in asthmatic patients
Source: Annual Congress 2011 - Lung function today and tomorrow I
Year: 2011

Respiratory impedance in healthy subjects: baseline values and bronchodilator response
Source: Eur Respir J 2013; 42: 1513-1523
Year: 2013



impulse oscillometry in Small airway dysfunction in asthmatics and its utility in asthma control .
Source: International Congress 2018 – Asthma management
Year: 2018



Assessment of different controller therapies in asthmatic children with pulmonary function tests
Source: Eur Respir J 2004; 24: Suppl. 48, 166s
Year: 2004

Repeatability and reproducibility of impulse oscillometry and body plethysmography in healthy, asthmatic and COPD subjects
Source: Annual Congress 2013 –Airway calibre, airway challenge and assessment of oxygenation
Year: 2013

Impulse oscillometry compared to standard lung function testing in patients with idiopathic pulmonary fibrosis
Source: International Congress 2018 – CTD-ILD and hypersensitivity pneumonitis:  mechanistic insights and prognostic markers
Year: 2018


Overweight is related to small airway function assessed by impulse oscillometry system (IOS) in asthmatic patients with normal spirometry
Source: Annual Congress 2013 –Clinical physiology and functional imaging in health and disease
Year: 2013