Forced inspiratory flows in normal subjects: reproducibility, determinants and normal values

S. Hanon, D. Schuermans, S. Verbanck, W. Vincken (Brussels, Belgium)

Source: Annual Congress 2001 - Airway reactivity in humans and animals
Session: Airway reactivity in humans and animals
Session type: Poster Discussion
Number: 330
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
S. Hanon, D. Schuermans, S. Verbanck, W. Vincken (Brussels, Belgium). Forced inspiratory flows in normal subjects: reproducibility, determinants and normal values. Eur Respir J 2001; 16: Suppl. 31, 330

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Normal values of forced inspiratory flows in healthy schoolchildren
Source: Eur Respir J 2003; 22: Suppl. 45, 307s
Year: 2003

Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry
Source: Eur Respir J 2008; 32: 1262-1268
Year: 2008



Sources of variation in forced expiratory volume in one second and forced vital capacity
Source: Eur Respir J 2006; 27: 767-773
Year: 2006



Peak in- and expiratory flow rates: reproducibility and reference values in adults
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


Spirometric measurement of inspiratory capacity in normal subjects: are the available references values useful?
Source: Eur Respir J 2002; 20: Suppl. 38, 380s
Year: 2002

Forced expiratory flows’ contribution to lung function interpretation in schoolchildren
Source: Eur Respir J 2015; 45: 107-115
Year: 2015



Reproducibility in parameters of forced inspiratory flow
Source: Annual Congress 2009 - Functional insights into COPD
Year: 2009

Prediction of inspiratory capacity in the normal population
Source: Eur Respir J 2001; 18: Suppl. 33, 12s
Year: 2001

Forced spirometry reference values for Norwegian adults: the Bronchial Obstruction in Nord-Trondelag study
Source: Eur Respir J 2001; 18: 770-779
Year: 2001



Exercise test results and forced expiratory flow rates at low lung volumes
Source: Eur Respir J 2002; 20: Suppl. 38, 286s
Year: 2002

Peak expiratory flow value and relationships between functional parameters in COPD
Source: Eur Respir J 2006; 28: Suppl. 50, 808s
Year: 2006

Does negative expiratory pressure (NEP) influence the performances of forced expiratory manoeuvres in elderly patient?
Source: Eur Respir J 2002; 20: Suppl. 38, 32s
Year: 2002

Recording flow in the first second of a maximal forced expiratory manoeuvre: influence of frequency content
Source: Eur Respir J 2002; 19: 530-533
Year: 2002



Does negative expiratory pressure influence performances of spirometry in older patients?
Source: Eur Respir J 2002; 20: 674-678
Year: 2002



Expiratory flow limitation under NEP (negative expiratory pressure) in patient with sleep disordered breathing (SDB) and controls: quantification of results
Source: Eur Respir J 2002; 20: Suppl. 38, 101s
Year: 2002

Grain workers; relationship between serial peak expiratory flow measurements, symptoms and lung function
Source: Eur Respir J 2002; 20: Suppl. 38, 392s
Year: 2002

Peak- and plateau maximal inspiratory mouth pressures in healthy subjects at different lung volumes
Source: Eur Respir J 2002; 20: Suppl. 38, 498s
Year: 2002

The ratio of inspiratory ΣRrs to expiratory ΣRrs measured by forced oscillation technique correlates with the parameters reflecting narrowing of small airway measured by spirometry in patients with mild to moderate COPD
Source: Annual Congress 2013 –New issues in lung function testing
Year: 2013

Normal values for maximal inspiratory and expiratory pressures of adolescents
Source: Annual Congress 2013 –Exercise and physiotherapy in non-COPD conditions and in the assessment of healthy subjects
Year: 2013


Forced vital capacity and forced expiratory volume in six seconds as predictors of reduced total lung capacity
Source: Eur Respir J 2008; 31: 391-395
Year: 2008