Usefulness of respiratory impedance by measuring at functional residual capacity position

Toshiyuki OGASA (Kitami City, Hokkaido, Japan), Toshiyuki Ogasa, Shinobu Osanai

Source: International Congress 2015 – Lung function: exploring the boundaries of the respiratory system
Session: Lung function: exploring the boundaries of the respiratory system
Session type: Thematic Poster Session
Number: 948
Disease area: Airway diseases

Congress or journal article abstractE-poster

Abstract

BackgroundThe Forced Oscillation Technique (FOT) can detect impairments of lung function by measuring the impedance of respiratory system during normal tidal breathing.ObjectiveWe assessed the clinical meaning of the respiratory impedance components measured at functional residual capacity (FRC) position.MethodsWe recruited 20 healthy male volunteers (age 23-57 years). We measured respiratory impedance by using a commercially available FOT device (MostGraph-01, Ver.1.70R) during normal tidal breathing. We analyzed respiratory resistance (Rrs) and reactance (Xrs) from 5 Hz to 20 Hz of oscillatory frequency at the level of FRC position defined as 0 of flow rate from expiratory phase to inspiratory phase. We also measured respiratory impedance during breath holding at the level of FRC position. We underwent standard pulmonary function tests. A P-value of <0.05 was considered significant.ResultsWe found negative relationships between height and Rrs at 5 Hz (R5), resonant frequency (Fres), and a positive relationship between height and Xrs at 5 Hz (X5). R5 adjusted by height was inversely correlated with FEV1(r=-0.57). X5 adjusted by height was positively correlated with FEV1 (r=0.62) and PEFR (r=0.55). Fres adjusted by height was inversely correlated with FEV1(r=-0.58). There were no relationships between the respiratory impedance components during breath holding and measurements of pulmonary function tests.DiscussionOur findings demonstrated that the respiratory impedance components at FRC, which was eliminated the effect of the elastic forces between lung and chest wall, had the correlation with FEV1, which would be represented dynamic phase of airway flow limitation.


Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Toshiyuki OGASA (Kitami City, Hokkaido, Japan), Toshiyuki Ogasa, Shinobu Osanai. Usefulness of respiratory impedance by measuring at functional residual capacity position. Eur Respir J 2015; 46: Suppl. 59, 948

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Role of the lung volume measurement in the diagnosis of obstructive diseases in patients with restrictive ventilatory impairment
Source: International Congress 2014 – Alterations of exercise and lung function in different diseases
Year: 2014

Airspace dimension test (ADT): A novel technique for diagnosis of the peripheral lung
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014


The airspace dimension test – A new way to diagnose emphysema?
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014

Contribution of respiratory resistance variability measured by forced oscillation technique (FOT) to assess the likelihood of asthma diagnosis
Source: International Congress 2016 – Functional assessment of the airways
Year: 2016


Impulse oscillometry assessment of small airway dysfunction pre- and post-bronchodilator in asthma and its relationship to disease severity
Source: International Congress 2014 – Alterations of exercise and lung function in different diseases
Year: 2014

Improved characterization of obstructive airways diseases by parameterization of specific resistance loops
Source: International Congress 2016 – Notable abstracts on clinical problems related to asthma
Year: 2016

Correlation among functional respiratory parameters and disease control in asthma
Source: International Congress 2015 – Is asthma always an easy disease to diagnose and manage?
Year: 2015


Computer bronchophonography is a new lung function diagnostic method in children
Source: International Congress 2014 – Respiratory function: quality and new technologies
Year: 2014


Shape analysis of specific resistance loop contributes to diagnosis of airflow obstruction
Source: International Congress 2015 – COPD: exacerbations, gas exchange and associated dysfunction
Year: 2015

The effects of standard therapy for COPD patients on FEV1 are associated with lower score of the Goddard classification
Source: International Congress 2014 – Multidimensional analysis of respiratory problems
Year: 2014


Can non-invasive measurements of respiratory phase angle offer a surrogate of disease severity in COPD? 2- Tidal breathing data
Source: Annual Congress 2013 –Various issues in clinical respiratory physiology
Year: 2013


The use of capnometry for alveolar ventilation assessment in COPD patients
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014


Mortality and classification of airway obstruction severity by different methods
Source: International Congress 2016 – Quality and quantity in lung function
Year: 2016


Relationships between spirometry, ventilation inhomogeneity and fast and slow ventilation lung units in COPD
Source: International Congress 2014 – Multidimensional analysis of respiratory problems
Year: 2014

The use of forced oscillation technique (FOT) to assess small airways dysfunction
Source: Annual Congress 2013 –Lung function tests to monitor airway diseases
Year: 2013

Evaluation of spirometric severity in COPD using dynamic chest X-ray examination
Source: Annual Congress 2013 –Functional imaging
Year: 2013

Early bronchial asthma diagnosis with electrical impedance spirometry
Source: Annual Congress 2013 –Airway calibre, airway challenge and assessment of oxygenation
Year: 2013


Measuring lung function in asthmatic children: A spirometry and forced oscillation technique (FOT) comparison
Source: International Congress 2016 – Highlights in primary ciliary dyskinesia and asthma in childhood
Year: 2016

Emphysema distribution determines distinct pulmonary function features
Source: Annual Congress 2013 –Asthma and COPD: diseases with different phenotypes
Year: 2013


Comparison between spirometry and computed tomography to evaluate dynamic hyperinflation in COPD patients
Source: International Congress 2014 – Functional imaging
Year: 2014