J. V. J. Lightowler, W. Gardner, M. W. Elliott (Leeds, United Kingdom)

Source: Annual Congress 2002 - Assessment of lung function, telemonitoring and quality of life
Session: Assessment of lung function, telemonitoring and quality of life
Session type: Thematic Poster Session
Number: 1000

Congress or journal article abstract

Abstract

Background When O2 is supplied using fixed performance Venturi masks, the manufacturers recommend a specific O2 flow rate. As O2 flow rates are often inaccurately set (Jeffery AA, Douglas NJ. Thorax 1989;44:1036-7) and because the provision of high flow rates during ambulatory O2 therapy quickly exhausts the cylinders, we investigated the effect of varying the O2 flow rate with different Venturi valves upon the resulting oxygen concentration (FiO2). Methods A custom-made lung model, connected to a resus dummy head, was used to simulate spontaneous breathing (minute ventilation 8.8Lpm). 24, 28 and 35% venturi valves, attached to a face mask (Medic-Aid), were evaluated at flow rates of 1-15Lpm. The recommended flow rates were 3, 6 and 10 respectively. O2 was supplied from a size 'G' cylinder and flow rate accurately measured with a pneumotachometer (Hans-Rudolf, Inc). The FiO2 was determined using an oxygen analyser (TED 60T, Teledyne Analytical Instruments). Results

The 24 and 28% valves performed well over the entire range of flow rates and the 35% valve at all flow rates in excess of 1Lpm. Conclusion When Venturi masks are used, incorrect setting of the O2 flow rate does not affect the FiO2. Using a 35% valve it was possible to deliver the desired FiO2 with a flow rate of just 2Lpm. Use of lower flow rates prolongs the time that oxygen can be delivered from a cylinder. JVJ Lightowler is funded by a British Lung Foundation Project Grant.


Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
J. V. J. Lightowler, W. Gardner, M. W. Elliott (Leeds, United Kingdom). Performance of venturi valves with different oxygen flow rates. Eur Respir J 2002; 20: Suppl. 38, 1000

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Performance of a novel humidification device for high flow oxygen therapy
Source: Eur Respir J 2006; 28: Suppl. 50, 189s
Year: 2006

A comparison of oxygen tubing lengths and flow output with home oxygen equipment. How much tubing is too much
Source: Eur Respir J 2004; 24: Suppl. 48, 517s
Year: 2004

Inspired oxygen fraction during non-invasive ventilation: the influence of flow rates, masks, exhalation ports and ventilatory settings
Source: International Congress 2018 – Non-invasive ventilation in chronic respiratory failure
Year: 2018


Comparison of pulsed flow from portable oxygen concentrators with continuous oxygen delivery.
Source: International Congress 2018 – What’s new in lung function and exercise assessment in COPD?
Year: 2018




Verification of flow rate stability in high-flow nasal cannula devices
Source: International Congress 2019 – Quality, performance and interpretation of lung function testing
Year: 2019


Performance of different low-flow oxygen delivery systems.
Source: Virtual Congress 2021 – Mechanical ventilation and weaning
Year: 2021


How high flow oxygen and NIV ventilators work
Source: ERS Course 2018 - Noninvasive ventilation: advanced
Year: 2018


Comparison of current high flow oxygen humidification systems with a novel humidifier (Pari HydrateÔ)
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007


Effects of different oxygen flow rates on CO2 retention in COPD patients with hipercapnic respiratory failure
Source: Eur Respir J 2003; 22: Suppl. 45, 242s
Year: 2003

NebuChamber® - valve opening at very low inspiratory flow rates
Source: Eur Respir J 2002; 20: Suppl. 38, 172s
Year: 2002

Consistency of aerosol characteristics at low flow rates for a novel mesh nebulizer
Source: International Congress 2018 – Pulmonary drug delivery: inhaler use, devices and technologies
Year: 2018


Determinants of Fi,O2 with oxygen supplementation during noninvasive two-level positive pressure ventilation
Source: Eur Respir J 2002; 19: 653-657
Year: 2002



High flow nasal oxygen – how does it work?
Source: International Congress 2014 – MS04 High flow nasal oxygen – what is the evidence?
Year: 2014




High flow nasal oxygen – does it work?
Source: International Congress 2014 – MS04 High flow nasal oxygen – what is the evidence?
Year: 2014




Effect of frequency on end-expiratory volume and gas exchange during different modes of jet ventilation
Source: Annual Congress 2010 - Mechanical ventilation and weaning
Year: 2010

High flow nasal cannula: influence of gas type and flow rate on positive airway pressure and CO2 clearance in adult nasal airway replicas
Source: International Congress 2018 – New tools for managing respiratory failure
Year: 2018


Continuous positive airway pressure, non-invasive ventilation and high flow nasal oxygen: lessons for success
Source: Virtual Congress 2021 – Continuous positive airway pressure, non-invasive ventilation and mechanical ventilation
Year: 2021


Impact of leakage on external flow measurement in non-invasive ventilation
Source: Annual Congress 2012 - Recent technical developments in long-term noninvasive ventilation
Year: 2012



Performance in tracking heart rate of a combined pulse oximeter and carbon dioxide sensor incorporating novel signal processing
Source: Eur Respir J 2005; 26: Suppl. 49, 116s
Year: 2005

Effectiveness of enhancement program of caring patients with high flow nasal cannula oxygen system
Source: International Congress 2019 – New strategies to treat respiratory failure
Year: 2019