Reproducibility of transcutaneous blood gas values in healthy children and adolescents

A. L. Lagerkvist, G. Sten, S. Redfors, D. Holmgren (Gothenburg, Sweden)

Source: Annual Congress 2002 - Assessment of lung function, telemonitoring and quality of life
Session: Assessment of lung function, telemonitoring and quality of life
Session type: Thematic Poster Session
Number: 997
Disease area: Paediatric lung diseases

Congress or journal article abstract

Abstract

To be able to judge the significance of changes in transcutaneous blood gas values between repeated measurements in patients it is necessary to know possible variations in these values in healthy children/adolescents.
The aim of the study was to establish transcutaneous oxygen tension (tcPO2), carbon dioxide tension (tcPCO2) and oxygen saturation (tcSO2) values and to investigate the intra- and inter-individual variation in these values in healthy children/adolescents.
Forty-one children/adolescents (mean age 12.1 years, SD 3.5) participated. Continuous recordings of tcPO2, tcPCO2 and tcSO2 were made for 30 minutes at two occasions with 10.3 days in between. The mean values of tcPO2, tcPCO2 and tcSO2 during the last five minutes of the recordings were reported.
At the first recording the mean was for tcPO2 10.8 kPa (SD 1.0), tcPCO2 5.1 kPa (SD 0.4) and tcSO2 97.4 % (1.1). The mean intra-individual variation was in tcPO2 0.3 kPa (SD 1.0), tcPCO2 0.0 kPa (0.5) and tcSO2 0.1 % (1.3). No significant differences were observed in these values between the recordings.
The reproducibility of tcPO2, tcPCO2 and tcSO2 monitoring in healthy children/adolescents were good. This indicates that transcutaneous monitoring may be used to document significant changes in blood gases over periods of time.


Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. L. Lagerkvist, G. Sten, S. Redfors, D. Holmgren (Gothenburg, Sweden). Reproducibility of transcutaneous blood gas values in healthy children and adolescents. Eur Respir J 2002; 20: Suppl. 38, 997

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Feasibility and repeatability of maximal respiratory pressures in healthy children
Source: Eur Respir J 2007; 30: Suppl. 51, 182s
Year: 2007

The reference values of volumetric capnography in the healthy adults
Source: Eur Respir J 2007; 30: Suppl. 51, 181s
Year: 2007

Maximal respiratory pressures and peak flows in healthy children and adolescents
Source: Eur Respir J 2001; 18: Suppl. 33, 423s
Year: 2001

Normal values of central and peripheral resistances derived from oscillometric measurements in healthy children
Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing
Year: 2008

Reference values of impulse oscillometry and their correlation with predictors in healthy Turkish preschool children
Source: International Congress 2018 – Improvements in the assessment of paediatric physiology
Year: 2018

Reference values for lung function testing using spirometry and Impulse oscillometry in healthy preschool-aged children in Korea
Source: Annual Congress 2010 - Advances in lung function from infancy to adolescence
Year: 2010

Reproducibility, reliability and diurnal variation of standardized exhaled NO measurements with NIOX™ in healthy and asthmatic children and adults made in routine clinical practice
Source: Eur Respir J 2001; 18: Suppl. 33, 4s
Year: 2001

Oscillometry reference values in preschool children
Source: International Congress 2017 – What is new in respiratory and sleep physiology?
Year: 2017

Reproducibility of sniff nasal Inspiratory pressure in healthy young adults
Source: Eur Respir J 2003; 22: Suppl. 45, 470s
Year: 2003

Repeatability of standardised nasal NO measurements with NIOX® in healthy and asthmatic children and adults made in routine clinical practice
Source: Eur Respir J 2003; 22: Suppl. 45, 442s
Year: 2003

Evaluation of the pulmonary blood flow and cardiac output via non-invasive hemodynamic measurement in young healthy volunteers
Source: Annual Congress 2009 - Pulmonary hypertension
Year: 2009


Measurement of lung distensibility in healthy children
Source: International Congress 2017 – Lung function practice in daily life
Year: 2017


Comparison of pulse oximetry and capillary blood gases pre and post six minute walk tests in healthy volunteers and patients with pulmonary arterial hypertension (PAH)
Source: Eur Respir J 2006; 28: Suppl. 50, 727s
Year: 2006

Respiratory impedance in healthy preschool children
Source: Annual Congress 2008 - Clinical applications of ventilatory function tests in paediatric pulmonology
Year: 2008


Assessing correlations between pulse oximetry and peak expiratory flow in children and adolescents with acute asthma
Source: Eur Respir J 2004; 24: Suppl. 48, 273s
Year: 2004

Feasibility and reproducibility of oscillometry for measuring respiratory function in young children: the SEPAGES cohort
Source: Virtual Congress 2020 – New insights into evaluation and treatment of respiratory disease
Year: 2020


Poor agreement between haemoglobin oxygen saturation measured by pulse oximetry and arterialized earlobe blood gas in ambulatory paediatric sickle cell patients
Source: International Congress 2016 – What's new in paediatric respiratory physiology?
Year: 2016

Normal values of forced inspiratory flows in healthy schoolchildren
Source: Eur Respir J 2003; 22: Suppl. 45, 307s
Year: 2003

Measurement of functional residual capacity (FRC) in infants and young children using an ultrasonic flowmeter for SF6 multiple breath washing/washout
Source: Eur Respir J 2002; 20: Suppl. 38, 19s
Year: 2002

Comparable measurements of FRC in healthy infants using three techniques
Source: Eur Respir J 2002; 20: Suppl. 38, 20s
Year: 2002