e-learning
resources
Munich 2014
Monday, 08.09.2014
Management of asthma and other respiratory diseases in primary care
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
Sealed-lips instruction for pressurised metered dose inhalers (pMDIs) – A critical step?
M. Sanders, R. Bruin, C. Tran (Harlow, Cardiff, United Kingdom)
Source:
International Congress 2014 – Management of asthma and other respiratory diseases in primary care
Session:
Management of asthma and other respiratory diseases in primary care
Session type:
Poster Discussion
Number:
3025
Disease area:
Airway diseases
Abstract
Background
: pMDI inserts include the mouthpiece instruction: close around/hold firmly between the lips. The perfect seal for laboratory testing may not, however, be representative of patient use.
Aim
: To determine gap-effects on salbutamol delivery from low (LR) and high resistance (HR), and breath-actuated (BA)/training pMDIs.
Methods
: Sealed and 0.18cm
2
gap adapters, and modified actuators to mimic low and high pMDI resistances were made. The four combinations were tested with Ventolin® Evohaler® (+standard actuator=Control), using a Next Generation Impactor™ operated to pharmacopoeial standard. The effect of sealed, small and large gaps (0.18 and 0.45 cm
2
) on the activation flow rate of salbutamol Autohaler®, Easi-Breathe® and the pMDI trainer Trainhaler®+Flo-Tone® were tested using a 1L/min/step waveform generator (MH Custom Design & Mfg LC, USA).
Results
: Pairwise comparisons of calculated lung dose % (stages 3-5, Table 1) indicated that resistance and gap significantly influenced lung dose; resistance more so. Activation flow rates were significantly larger (P<0.05) for gapped than sealed devices (Table 2).
Conclusion
: The sealed-lips instruction particularly affected non-BA pMDI lung dose from low resistance devices, but is unlikely to be detectable clinically. The instruction is critical for BA devices, and may impact clinically where patients use both types of device. Sealed lips should remain the default instruction.
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
M. Sanders, R. Bruin, C. Tran (Harlow, Cardiff, United Kingdom). Sealed-lips instruction for pressurised metered dose inhalers (pMDIs) – A critical step?. Eur Respir J 2014; 44: Suppl. 58, 3025
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Late Breaking Abstract - Implications of treatable traits and treatment choices on exacerbation risk in moderate-severe asthma
Management of Severe Asthma in Pediatric Patients by an Interdisciplinary Team in a Public Hospital Setting.
Respiratory sequelae of preterm birth across the life span
Related content which might interest you:
Valved holding chambers (VHCs) can have different medication delivery performance as a function of delay interval following actuation of the pressurized metered dose inhaler (pMDI)
Source: International Congress 2014 – Respiratory symptoms in primary care populations
Year: 2014
Delivery of medication by breath-actuated nebulizer (BAN) is similar when used with differing inhalation / exhalation ratios: A contrast to breath enhanced nebulizer (BEN) behavior
Source: International Congress 2014 – Respiratory symptoms in primary care populations
Year: 2014
The effect of inhalation duration on lung deposition with a pressurized metered-dose inhaler (pMDI)
Source: International Congress 2014 – Asthma and COPD devices and treatments
Year: 2014
LATE-BREAKING ABSTRACT: Profiling of single maintenance and reliever therapy (SMART) dosing instructions of budesonide/formoterol (BFC) in clinical practice
Source: International Congress 2014 – Management of COPD in primary care
Year: 2014
LATE-BREAKING ABSTRACT: Effectiveness of training session on the inhalation technique of the BA-pMDI Autohaler® (containing beclometasone) in daily practice.
Source: Annual Congress 2013 –Improving educational programmes for patients and multidisciplinary healthcare professionals
Year: 2013
Health care professionals's features of an ideal inhaler in testing new inhaler device. Does it recognize their needs?
Source: International Congress 2014 – Medical education: web and internet
Year: 2014
Asthma management: important issues
Source: Eur Respir Rev 2005; 14: 147-151
Year: 2005
Medical students’ understanding of inhalation therapy & inhalers
Source: Annual Congress 2013 –Improving educational programmes for patients and multidisciplinary healthcare professionals
Year: 2013
Inhaler proficiency following the introduction of a new inhaler management policy for hospitalised patients
Source: International Congress 2014 – From individual patient interactions to models of care: the nursing perspective
Year: 2014
Investigating inhaler device mastery in pharmacist trainees
Source: International Congress 2015 – Healthcare organisation and appropriateness in lung disorders
Year: 2015
Canadian physicians are concerned about the use of inhaled corticosteroids (ICS) in COPD management
Source: International Congress 2014 – Management of asthma and other respiratory diseases in primary care
Year: 2014
In vitro lung deposition of fluticasone propionate/formoterol (FP/FORM) pressurized metered dose inhaler (pMDI) with different inhalation profiles
Source: International Congress 2014 – Asthma and COPD devices and treatments
Year: 2014
Inhaled medication delivery to infants via valved holding chamber with facemask: Not all VHCs perform the same
Source: International Congress 2014 – Paediatric asthma: lung function testing and more
Year: 2014
Ease of use of a two-strip dry powder inhaler (DPI) to deliver fluticasone furoate/vilanterol (FF/VI) and FF alone in asthma
Source: Annual Congress 2013 –Asthma and COPD drugs: efficacy, safety and pharmacoeconomics
Year: 2013
Inhaler technique – A time to re-educate patients?
Source: International Congress 2014 – Clinical management of lung diseases: from bronchi to pleura
Year: 2014
Metered-dose inhaler albuterol: Evaluation of efficacy and safety of increasing doses in children with acute wheezing
Source: International Congress 2014 – Paediatric asthma: lung function testing and more
Year: 2014
Changing a hospital inhaler policy to improve in-hospital inhaler use
Source: International Congress 2014 – Non inflammatory monitoring of airway diseases
Year: 2014
INhaler compliance assessment in the community (INCA GP)
Source: International Congress 2014 – Management of asthma and other respiratory diseases in primary care
Year: 2014
Comparison of asthma and COPD patients' perception of appropriate metered-dose inhaler technique with a questionnaire and supervision based reference standard
Source: International Congress 2014 – Clinical assessment of airway diseases
Year: 2014
Prevalence of serious post-training inhaler technique errors made by device-naïve patients using three different dry powder inhalers (DPIs)
Source: International Congress 2015 – Novel strategies for the management of asthma, COPD and airway infections
Year: 2015
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept