e-cigarette constituents and particle emission Source: International Congress 2015 – E-cigarettes: a wolf in sheep's clothing or a sheep in wolf's clothing? Year: 2015
Effect of respirators with particle or particle and gas filters following exposure in a swine confinement building Source: Eur Respir J 2004; 24: Suppl. 48, 450s Year: 2004
Particle size and gravimetric characteristics of Clenny Aerosol, a new jet nebulizer with breath enhanced bulb Source: Eur Respir J 2001; 18: Suppl. 33, 99s Year: 2001
Welding fumes change the lipid composition of particles in exhaled air. Source: International Congress 2018 – Occupational and environmental lung diseases: mechanisms, biomarkers and causation Year: 2018
Hazardous levels of PM2.5 (particulate matter less than 2.5 microns in mean aerodynamic diameter) are emitted during burning of individual fire crackers in India Source: International Congress 2016 – Targeting care, pulmonary rehabilitation, management, and self-management of COPD exacerbations in primary care Year: 2016
Particle content in exhaled air depending on breathing maneuver Source: Annual Congress 2012 - Exhaled biomarkers in airway diseases Year: 2012
The generation of monodisperse pharmacological aerosols using a spinning-top aerosol generator (STAG) Source: Eur Respir J 2005; 26: Suppl. 49, 125s Year: 2005
A breath-actuated nebulizer provides greatly reduced fugitive aerosol emissions compared with a continuously operating nebulizer Source: Annual Congress 2007 - Miscellaneous pulmonary pharmacology II Year: 2007
Impact of e-liquid composition on the emission and inhalation of carbonyl compounds Source: Virtual Congress 2020 – Health effects of inhaled nicotine devices: from smoking to vaping and heated tobacco Year: 2020
A generator for short-duration exposures to micron-size aerosols Source: Eur Respir J 2002; 20: Suppl. 38, 517s Year: 2002
Effect of tidal volume on fugitive emissions during mechanical ventilation Source: International Congress 2018 – Preclinical and clinical studies of critical illness Year: 2018
Air quality evaluation in a pulmonary unit room using a portable volumetric sampler for airborne particles (PARTRAP FA 52) Source: Eur Respir J 2001; 18: Suppl. 33, 141s Year: 2001
Influence of extremely low attenuation pixel values on specific gas volume calculation for the assessment of emphysema and gas trapping by computed tomography Source: Annual Congress 2010 - Infection, inflammation and destruction Year: 2010
Air pollution: particle size matters Source: Virtual Congress 2020 – Air pollution and interstitial lung disease: a call to arms Year: 2020
Inhalation of thoron (Tn) gas in controlled conditions of high background radiation (HBR) using natural thorium: Radioactive dose deposition and acute pneumocystis changes in mouse Source: Virtual Congress 2020 – Translational aspects of idiopathic pulmonary fibrosis Year: 2020
Breath-holding increases the number of particles in exhaled air Source: Annual Congress 2010 - From rare towards common lung diseases: diagnostic and monitoring challenges Year: 2010
Inner coating of condenser systems influences detection of albumin in exhaled breath condensate Source: Eur Respir J 2003; 22: Suppl. 45, 280s Year: 2003