e-learning
resources
Vienna 2012
Sunday, 02.09.2012
Pathophysiological mechanisms in disease: new insights
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
Comparison of measures of ventilation heterogeneity derived from multiple breath inert gas washout
S. Gonem, S. Corkill, A. Singapuri, D. Desai, P. Gustafsson, C. Brightling, S. Siddiqui (Leicester, United Kingdom; Skövde, Sweden)
Source:
Annual Congress 2012 - Pathophysiological mechanisms in disease: new insights
Session:
Pathophysiological mechanisms in disease: new insights
Session type:
Poster Discussion
Number:
245
Disease area:
Airway diseases
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
S. Gonem, S. Corkill, A. Singapuri, D. Desai, P. Gustafsson, C. Brightling, S. Siddiqui (Leicester, United Kingdom; Skövde, Sweden). Comparison of measures of ventilation heterogeneity derived from multiple breath inert gas washout. Eur Respir J 2012; 40: Suppl. 56, 245
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Late Breaking Abstract - Implications of treatable traits and treatment choices on exacerbation risk in moderate-severe asthma
Management of Severe Asthma in Pediatric Patients by an Interdisciplinary Team in a Public Hospital Setting.
Respiratory sequelae of preterm birth across the life span
Related content which might interest you:
Comparison of helium and sf6 multiple breath gas washout techniques in spontaneously breathing infants
Source: Eur Respir J 2003; 22: Suppl. 45, 383s
Year: 2003
Validation of a multiple breath inert gas washout technique using a lung phantom
Source: Annual Congress 2012 - Various issues in clinical physiology
Year: 2012
Modifications to a photoacoustic gas analyser increases accuracy of functional residual capacity measurements by multiple breath washout of SF
6
in an infant lung model
Source: Annual Congress 2008 - Clinical applications of ventilatory function tests in paediatric pulmonology
Year: 2008
Comparison of ventilation inhomogeneity assessed by VC and tidal breath inert gas washout in children with mild-to-severe CF lung disease
Source: Eur Respir J 2001; 18: Suppl. 33, 347s
Year: 2001
Double-tracer gas single breath washout - Variability and reproducibility compared with classical nitrogen washout tests
Source: Annual Congress 2013 –New issues in lung function testing
Year: 2013
Mitigating increased variability of multiple breath washout indices due to tidal breathing
Source: Eur Respir J, 57 (2) 2002765; 10.1183/13993003.02765-2020
Year: 2021
Determination of functional residual capacity and moment ratio from multiple breath inert gas wash-ins
Source: Annual Congress 2008 - Lung function in respiratory disease
Year: 2008
Do deviations in tidal breathing impact multiple breath washout measurements?
Source: International Congress 2018 – Cystic fibrosis: diagnosis and monitoring
Year: 2018
Influence of gas concentration and measurement interval on the reproducibility of non-invasive cardiac output determination by inert gas rebreathing in pulmonary healthy patients
Source: Annual Congress 2011 - Innovative methods in exercise testing
Year: 2011
Comparison of helium dilution and sulphur hexafluoride multiple breath measurements of functional residual capacity in neonates
Source: Eur Respir J 2007; 30: Suppl. 51, 396s
Year: 2007
Closed circuit rebreathing to achieve inert gas wash-in for multiple breath wash-out
Source: ERJ Open Res 2016
Year: 2016
Outcome of multiple breath washout (MBW) in healthy children using two different gases (N2 and SF6) with the same equipment
Source: International Congress 2017 – What is new in respiratory and sleep physiology?
Year: 2017
Simultaneous estimation of partitioned FeNO sources and airway dimensions with tidal breath data
Source: International Congress 2019 – FeNO in airway diseases and asthma-COPD overlap identification
Year: 2019
Reference values for lung clearance index (LCI) derived from sulphur hexafluoride multiple breath washout testing.
Source: Virtual Congress 2020 – Lung function tests and exhaled biomarkers
Year: 2020
Estimation of lung functional residual capacity by the multiple-breath washout test versus bodyplethysmography in healthy subjects
Source: Virtual Congress 2020 – Lung function diagnostics
Year: 2020
The impact of gas analysis technique on the measurement of single breath gas transfer (TLCO)
Source: International Congress 2015 – Lung function: effects on method, machine and disease on the measurement
Year: 2015
Comparison of a new nitrogen multiple breath washout method to mass spectrometer SF6 washout in cystic fibrosis subjects
Source: Annual Congress 2011 - Advances in lung function testing from infancy to adulthood
Year: 2011
Comparison of two devices and two breathing patterns for exhaled breath condensate sampling
Source: Annual Congress 2011 - Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Year: 2011
Automated detection of the alveolar plateau during multiple breath nitrogen washout
Source: Annual Congress 2010 - Advances in lung function II
Year: 2010
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept