Comparison of airway resistance (RAW) measurements by the forced oscillation technique (FOT) and the interrupter technique (RINT) for detecting obstructive lung disease (OLD) in elderly patients

Y. F. Guo, F. Herrmann, S. Ghezal, J. Leriche, J. P. Michel, J. P. Janssens (Geneva, Switzerland)

Source: Annual Congress 2004 - Assessment of lung diseases
Session: Assessment of lung diseases
Session type: Thematic Poster Session
Number: 1836
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Y. F. Guo, F. Herrmann, S. Ghezal, J. Leriche, J. P. Michel, J. P. Janssens (Geneva, Switzerland). Comparison of airway resistance (RAW) measurements by the forced oscillation technique (FOT) and the interrupter technique (RINT) for detecting obstructive lung disease (OLD) in elderly patients. Eur Respir J 2004; 24: Suppl. 48, 1836

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
The use of forced oscillation technique (FOT) in assessment of airway obstruction and airtrapping in elderly COPD patients
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011


Is the forced oscillation technique (FOT) useful to assess bronchodilatator response (BDLR) in COPD?
Source: Eur Respir J 2007; 30: Suppl. 51, 600s
Year: 2007

Forced oscillation technique (FOT) and Impulse Oscillometry (IOS) depict longer duration of disease in children with Sickle cell disease (SCD) while N2-Multiple-breath-washout (N2MBW) provides new insight on respiratory pattern
Source: International Congress 2019 – Severe acute asthma and troublesome wheezing
Year: 2019


Post-bronchodilator response (PBDR) evaluated by plethysmographic and spirometric target parameters in patients with COPD, asthma-COPD-overlap (ACO) and asthma
Source: International Congress 2018 – Innovations in equipment and their application
Year: 2018



Comparison of two methods of detection of expiratory flow limitation (EFL) in chronic obstructive pulmonary disease (COPD): Sinusoids vs. Impulse oscillometry
Source: Annual Congress 2010 - Spotlight on lung function
Year: 2010

Reproducibility of resistance (R) and reactance (X) responses to bronchodilator (BD) measured by the impulse oscillation system (IOS) in patients with stable COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 63s
Year: 2005

Upper airway (UAW) pressure-flow response to electrical stimulation (ES) of tongue protrusors (TP) and retractors (TR) in patients with obstructive sleep apnea (OSA)
Source: Eur Respir J 2001; 18: Suppl. 33, 332s
Year: 2001

The use of forced oscillation technique (FOT) in assessment and stratification of disease severity in elderly COPD patients
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011


Reproducibility of resistance (R) and reactance (X) measured with the impulse oscillation system (IOS) in patients with COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 65s
Year: 2005

Forced oscillation technique (FOT) in the evaluation of COPD patients enrolled in Pulmonary Rehabilitation (PR)
Source: International Congress 2019 – Hot topics in pulmonary rehabilitation
Year: 2019

Methacholine challenge in preschool children: comparison of transcutaneous measurement of oxygen (PtcO2), resistance by interrupter technique (Rint) and specific airway resistance (sRaw)
Source: Eur Respir J 2006; 28: Suppl. 50, 707s
Year: 2006

Exercise capacity and dyspnea challenge of adult chronic obstructive lung disease (COPD) patients when using a novel mesh nebulizer compared to traditional jet nebulizer (TJN)
Source: Virtual Congress 2020 – Inhaler devices in COPD: technical advances, adherence studies and more
Year: 2020


Correlation between spirometric indices (FEV1, FVC) and lung diffusion values (DLCO) in subjects with varying severity of chronic obstructive pulmonary disease (COPD)
Source: Annual Congress 2007 - Primary care respiratory problems
Year: 2007


Relationship between lung function using forced oscillation technique (FOT) with recent symptoms in young children with asthma
Source: Annual Congress 2011 - Advances in lung function testing from infancy to adulthood
Year: 2011


Forced oscillometry technique (FOT) used to detect children with inapparent asthma
Source: Eur Respir J 2002; 20: Suppl. 38, 171s
Year: 2002

Is interrupter resistance (Rint) flow dependent in children and adult COPD patients?
Source: Eur Respir J 2001; 18: Suppl. 33, 206s
Year: 2001

Detection of expiratory flow limitation in COPD using the forced oscillation technique
Source: Eur Respir J 2004; 23: 232-240
Year: 2004



Comparison of functional residual capacity (FRC) measured by plethysmography (FRCpleth) and multiple breath washout (FRCmbw) in schoolchildren with cystic fibrosis (CF).
Source: International Congress 2018 – Respiratory physiology and measurements
Year: 2018

Comparison between presence of respiratory symptoms and peak expiratory flow (PEF) values <80% predicted as screening tools for obstructive airways diseases (OAD)
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011

Preference and quality of life of adult chronic obstructive lung disease (COPD) patients when using a novel mesh nebulizer compared to traditional jet nebulizer (TJN)
Source: Virtual Congress 2020 – Inhaler devices in COPD: technical advances, adherence studies and more
Year: 2020