Late-breaking abstract: Prevalence of emphysema heterogeneity measured with thoracic computed tomography soft in combination with collateral ventilation assessment to plan endoscopic volume reduction

C. Pison, A. Jankowski, S. Quétant, M. Jondot, C. Chérion, G. Ferretti, W. Aniwidyaningsih (Grenoble, France; Jakarta, Indonesia)

Source: Annual Congress 2011 - Treatment beyond inhalers: endoscopic lung volume reduction
Session: Treatment beyond inhalers: endoscopic lung volume reduction
Session type: Poster Discussion
Number: 3526
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
C. Pison, A. Jankowski, S. Quétant, M. Jondot, C. Chérion, G. Ferretti, W. Aniwidyaningsih (Grenoble, France; Jakarta, Indonesia). Late-breaking abstract: Prevalence of emphysema heterogeneity measured with thoracic computed tomography soft in combination with collateral ventilation assessment to plan endoscopic volume reduction. Eur Respir J 2011; 38: Suppl. 55, 3526

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Functional measurement of collateral ventilation is of additional value to CT scan fissure analysis in endobronchial valve treatment for emphysema
Source: International Congress 2019 – New insights into pleural and bronchoscopic interventions
Year: 2019

Comparison of quantitative CT (QCT) with Chartis measurement to assess collateral ventilation as predictor of success in endoscopic lung volume reduction with valves
Source: International Congress 2017 – Interventional pulmonology highlights 2017
Year: 2017

Computed tomography assessment of lung volume changes after bronchial valve treatment
Source: Eur Respir J 2008; 32: 1443-1450
Year: 2008



MDCT volumetric assessment of the lung in patients undergoing bronchial stenting for treatment of pulmonary emphysema: correlation with respiratory tests
Source: Annual Congress 2006 - COPD: imaging and computer applications
Year: 2006


Comparison of software based CT fissure analyses and endobronchial in-vivo measurements for detection of collateral ventilation for endoscopic lung volume reduction
Source: International Congress 2016 – Endoscopic lung volume reduction II
Year: 2016

High-resolution computed axial tomography findings suggestive of pulmonary arterial hypertension in lung transplant candidates: correlation with cardiological and pneumectomy piece obtained after surgical procedure
Source: Eur Respir J 2006; 28: Suppl. 50, 725s
Year: 2006

Volume correction of CT densitometry in drug evaluation trials on pulmonary emphysema: a simulation study
Source: Annual Congress 2005 - New modalities and application in lung and airway imaging
Year: 2005


Degree of concordance between spiral computed tomography and ventilation perfusion lung scan in the diagnosis of pulmonary thromboembolism
Source: Eur Respir J 2006; 28: Suppl. 50, 773s
Year: 2006

Evaluation of spirometry-gated computed tomography to measure lung volumes in emphysema patients
Source: ERJ Open Res, 8 (1) 00492-2021; 10.1183/23120541.00492-2021
Year: 2022



Feasibility of low-dose computed tomography in follow up of patients with severe emphysema after airway bypass procedure
Source: Eur Respir J 2006; 28: Suppl. 50, 594s
Year: 2006

High resolution computed tomography (HRCT) measurements of lobar volume reduction associated with bronchoscopic thermal vapor ablation (BTVA) in patients with heterogeneous emphysema
Source: Annual Congress 2011 - Treatment beyond inhalers: endoscopic lung volume reduction
Year: 2011


Evaluation of regional lung ventilation using xenon-enhanced computed tomography in patients with asthma
Source: Eur Respir J 2006; 28: Suppl. 50, 223s
Year: 2006

Landmark papers in respiratory medicine: Automatic quantification of emphysema and airways disease on computed tomography
Source: Breathe 2016; 12: 79-81
Year: 2016


Densitometry for assessment of effect of lung volume reduction surgery for emphysema
Source: Eur Respir J 2007; 29: 1138-1143
Year: 2007



Airway bypass procedure: quantitative low dose multi-detector computed tomography and pulmonary function tests in patients with severe emphysema
Source: Annual Congress 2007 - Imaging modalities in asthma, COPD and emphysema
Year: 2007


Surgery for emphysema: medical aspects
Source: ISSN=1025-448x, ISBN=1-904097-33-2, page=129
Year: 2004

Objective quantitative multi-detector computed tomography assessments in patients with combined pulmonary fibrosis with emphysema
Source: International Congress 2019 – Imaging: new insights that pulmonologists should be aware of
Year: 2019



Computed tomographic estimation of lung dimensions throughout the growth period
Source: Eur Respir J 2006; 27: 261-267
Year: 2006



Change in perfusion patterns and its correlation to clinical outcomes following lung volume reduction surgery (LVRS) in COPD as assessed by single photon emission computer tomography (SPECT)
Source: Annual Congress 2011 - Pleural diseases and pneumothorax
Year: 2011


Airway–artery quantitative assessment on chest computed tomography in paediatric primary ciliary dyskinesia
Source: ERJ Open Res, 6 (3) 00210-2019; 10.1183/23120541.00210-2019
Year: 2020