FEF25-75% should not yet be used to define a bronchodilator response in individuals

M. P. Swanney, L. E. Beckert, C. M. Frampton, R. L. Jensen, R. O. Crapo (Christchurch, New Zealand; Salt Lake City, United States Of America)

Source: Annual Congress 2005 - Spirometry - now and in the future
Session: Spirometry - now and in the future
Session type: Oral Presentation
Number: 4225
Disease area: Airway diseases

Congress or journal article abstractSlide presentation

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
M. P. Swanney, L. E. Beckert, C. M. Frampton, R. L. Jensen, R. O. Crapo (Christchurch, New Zealand; Salt Lake City, United States Of America). FEF25-75% should not yet be used to define a bronchodilator response in individuals. Eur Respir J 2005; 26: Suppl. 49, 4225

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Normal lung function and absence of bronchodilator response in children with stable, controlled asthma using inhaled corticosteroids
Source: Annual Congress 2006 - New features of paediatric asthma
Year: 2006


Ratio between forced expiratory flow between 25% and 75% of VC and FVC as a determinant of airway reactivity and sensitivity to methacholine
Source: Eur Respir J 2006; 28: Suppl. 50, 219s
Year: 2006

IsovolumeFEF25-75%6 and FEV1 for identifying bronchodilator response
Source: Eur Respir J 2006; 28: Suppl. 50, 156s
Year: 2006

Should forced expiratory volume in six seconds replace forced vital capacity to detect airway obstruction?
Source: Eur Respir J 2006; 27: 1244-1250
Year: 2006



The role of forced partial expiratory flows to test the bronchodilator response in COPD
Source: Annual Congress 2012 - Pathophysiological mechanisms in disease: new insights
Year: 2012


Is the forced expiratory volume in 6 seconds (FEV6) a more reproducible and accurate measurement than forced vital capacity (FVC) in obstructive and normal/restrictive patients
Source: Eur Respir J 2001; 18: Suppl. 33, 13s
Year: 2001

Prediction of all cause mortality in a population sample is improved by using FEV1 quotient
Source: Annual Congress 2005 - Assessing the relevance of obstructive airway diseases
Year: 2005


FEV6 or FVC to detect airway obstruction in the community setting?
Source: Annual Congress 2007 - PG17 - Lung function measurement in the community
Year: 2007



Annual decline in forced expiratory volume in 1 sec (FEV1) in patients with COPD before and after introduction of tiotropium
Source: Annual Congress 2008 - Pathogenesis and treatment of asthma and COPD
Year: 2008

Osteoprotogerin plasma concentrations is correlate with forced expiratory volume at 1 second (FEV1) in patients with COPD
Source: Annual Congress 2013 –Systemic and airway biomarkers in respiratory diseases
Year: 2013


Lung function measurement in respiratory diseases: mechanisms
Source: Annual Congress 2006 - PG5 - Respiratory physiology: interpreting lung function in health and disease
Year: 2006



Why should we perform lung function tests?
Source: Annual Congress 2007 - PG17 - Lung function measurement in the community
Year: 2007



FEV6 as a surrogate for FVC in detecting airways obstruction and restriction in the workplace
Source: Eur Respir J 2006; 27: 374-377
Year: 2006



Forced spirometry reference values for Norwegian adults: the Bronchial Obstruction in Nord-Trondelag study
Source: Eur Respir J 2001; 18: 770-779
Year: 2001



Sources of variation in forced expiratory volume in one second and forced vital capacity
Source: Eur Respir J 2006; 27: 767-773
Year: 2006



Analysis of the post bronchodilator forced expiratory volume in one second of COPD patients clinically followed up for three years
Source: Annual Congress 2013 –COPD diagnosis
Year: 2013


FEV6 and FEV1/FEV6 have higher association with small airway function and oxygen saturation than FVC and FEV1/FVC in patients with asthma.
Source: Virtual Congress 2020 – Lung function tests and exhaled biomarkers
Year: 2020

Forced expiratory volume in one second (FEV1) and peak expiratory flow (PEF): is there a correlation in chronic obstructive pulmonary disease (COPD) patients?
Source: Eur Respir J 2001; 18: Suppl. 33, 213s
Year: 2001

The effect of nebulised MgSO4 on lung function in stable severe asthma patients with persistent airflow limitation
Source: Annual Congress 2007 - New drugs for asthma
Year: 2007




The relationship between peak expiratory flow rate (PEFR) and forced expiratroy volume in the first second (FEV1) at low levels of FEV1. Implications for the assessment of COPD (chronic obstructive pulmonary disease) in primary care
Source: Eur Respir J 2002; 20: Suppl. 38, 397s
Year: 2002