Methacholine challenge in preschool children: comparison of transcutaneous measurement of oxygen (PtcO2), resistance by interrupter technique (Rint) and specific airway resistance (sRaw)

J. Bouguila, J. P. Jais, S. Waernessyckle, P. Scheinmann, J. de Blic, M. Le Bourgeois (Paris, France)

Source: Annual Congress 2006 - Diagnostic paediatric lung function: technical and clinical aspects
Session: Diagnostic paediatric lung function: technical and clinical aspects
Session type: Thematic Poster Session
Number: 4071
Disease area: Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
J. Bouguila, J. P. Jais, S. Waernessyckle, P. Scheinmann, J. de Blic, M. Le Bourgeois (Paris, France). Methacholine challenge in preschool children: comparison of transcutaneous measurement of oxygen (PtcO2), resistance by interrupter technique (Rint) and specific airway resistance (sRaw). Eur Respir J 2006; 28: Suppl. 50, 4071

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Measurement of airway resistance by the interrupter technique (Rint) in preschool children
Source: Eur Respir J 2002; 20: Suppl. 38, 223s
Year: 2002

Spirometry and measurement of airway resistance by the interrupter technique (rint) in preschool children: Influence of atopy
Source: Annual Congress 2011 - Biological correlates and comorbidities of childhood asthma/allergy
Year: 2011


Airway resistance measured by the interrupter technique: expiration or inspiration, mean or median?
Source: Eur Respir J 2001; 17: 495-498
Year: 2001



Interrupter resistance and oxygen saturation for methacholine challenge in young children
Source: ERJ Open Res 2015; 1: 00025-2015
Year: 2015


Measurement of airway resistance using the interrupter technique (Rint): changes after broncho-provocation and -dilation
Source: Eur Respir J 2001; 18: Suppl. 33, 206s
Year: 2001

Reliability of specific airway resistance (sRaw) by body plethysmographic technique in healthy subjects
Source: Eur Respir J 2006; 28: Suppl. 50, 281s
Year: 2006

Can airway resistance, measured by the interrupter technique, be useful in evaluating the methacholine bronchial challenge test in children?
Source: Eur Respir J 2004; 24: Suppl. 48, 585s
Year: 2004

How should airways resistance be measured in young children: mask or mouthpiece?
Source: Eur Respir J 2001; 17: 1244-1249
Year: 2001



Measurement of airway resistance using the interrupter technique (Rint) in preschool children with bronchopulmonary dysplasia in ambulatory setting
Source: Eur Respir J 2004; 24: Suppl. 48, 377s
Year: 2004

Respiratory resistance measured by the interrupter technique: feasibility versus spirometry in 7 to 8 years children
Source: Annual Congress 2008 - Diagnostic paediatric lung function: technical and clinical aspects
Year: 2008


Methacholine challenge test with impulse oscillometry versus spirometry: which is more sensitive in detecting airway hyper-responsiveness (AHR?)
Source: International Congress 2018 – Clinical and functional monitoring in airway disease
Year: 2018

Is interrupter resistance (Rint) flow dependent in children and adult COPD patients?
Source: Eur Respir J 2001; 18: Suppl. 33, 206s
Year: 2001

Does interrupter resistance (Rint) have a role in the assessment of children with acute asthma?
Source: Eur Respir J 2003; 22: Suppl. 45, 314s
Year: 2003

The interrupter technique (Rint): which algorithm is best for detecting bronchodilator response in children?
Source: Eur Respir J 2001; 18: Suppl. 33, 347s
Year: 2001

Can the interrupter resistance be used to measure airway hyperresponsiveness during the methacholine challenge test as a substitute for FEV1?
Source: Virtual Congress 2021 – New insights into lung function testing
Year: 2021


Airway resistance during the methacholine challenge test: Comparison between impulse oscillometry and plethysmographic technique
Source: Annual Congress 2011 - Lung and airway function
Year: 2011

Bronchial provocation in children assessed by spirometry and airway resistance using interrupter technique: Comparison of two methods
Source: Annual Congress 2010 - Airways and lung mechanics in subjects of all ages
Year: 2010


Respiratory impedance response to a deep inhalation (DI) in children during methacholine (MCh) challenge
Source: Eur Respir J 2001; 18: Suppl. 33, 347s
Year: 2001

Comparison of airway resistance (RAW) measurements by the forced oscillation technique (FOT) and the interrupter technique (RINT) for detecting obstructive lung disease (OLD) in elderly patients
Source: Eur Respir J 2004; 24: Suppl. 48, 283s
Year: 2004

Interrupter resistance and pressure oscillation analysis during bronchoprovocation testing in pre-school children
Source: Annual Congress 2007 - Paediatric respiratory physiology in health and disease
Year: 2007