e-learning
resources
Glasgow 2004
Monday 06.09.2004
Lung function technology: beyond the basic test
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
Reproducibility of resting oxygen uptake measurements and consequence for calculated cardiac output
C. A. Klein, H. Groepenhoff, S. Holverda, F. Oosterveer, A. Vonk-Noordegraaf, P. E. Postmus (Amsterdam, The Netherlands)
Source:
Annual Congress 2004 - Lung function technology: beyond the basic test
Session:
Lung function technology: beyond the basic test
Session type:
Thematic Poster Session
Number:
2494
Disease area:
Pulmonary vascular diseases
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
C. A. Klein, H. Groepenhoff, S. Holverda, F. Oosterveer, A. Vonk-Noordegraaf, P. E. Postmus (Amsterdam, The Netherlands). Reproducibility of resting oxygen uptake measurements and consequence for calculated cardiac output. Eur Respir J 2004; 24: Suppl. 48, 2494
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Panel discussion: Diagnostic tools for Obstructive Sleep Apnoea in adults and children
Expert interview: Physiological classification of lung function impairment
Occupational exposures to respiratory diseases: A case-based discussion
Related content which might interest you:
Prediction of individual cardiac output from measured VO2 and ventilation
Source: International Congress 2018 – Innovations in equipment and their application
Year: 2018
Reduced oxygen uptake efficiency slope in patients with cardiac sarcoidosis
Source: Annual Congress 2012 - Limiting factors in exercise
Year: 2012
Does oxygen pulse trajectory during incremental exercise discriminate impaired oxygen delivery from poor muscle oxygen utilisation?
Source: ERJ Open Res, 5 (2) 00108-2018; 10.1183/23120541.00108-2018
Year: 2019
Modification of inspired oxygen fraction does not change exercise oxygen uptake measured by JAEGER® Vyntus CPX; a validation study
Source: International Congress 2018 – Innovations in equipment and their application
Year: 2018
Kinetics of haemoglobin oxygen saturation measured by continuous pulse oximetry during the 6 minute walking test
Source: Annual Congress 2008 - Pulmonary rehabilitation for non-COPD and severe COPD; field exercise testing
Year: 2008
Voxelotor, which left shifts the oxy-hemoglobin dissociation curve, improves oxygen desaturation in IPF patients during maximal exercise
Source: International Congress 2019 – Exploring exercise responses in respiratory diseases
Year: 2019
Oxygen uptake measured at the ventilatory threshold is a mortality marker in COPD
Source: Virtual Congress 2020 – Exploring respiratory function
Year: 2020
Impact of automatic oxygen titration alone or with high flows on exercise tolerance in patients with lung disease and exercise oxygen desaturation
Source: Virtual Congress 2020 – New insights into evaluation and treatment of respiratory disease
Year: 2020
Validation of the assessment of flow limitation at rest by overlapping of the tidal and maximal flow volume curves
Source: Annual Congress 2009 - Quality control in lung function and new developments
Year: 2009
Variability of oxygen saturation measurements from different pulse oximeters
Source: Eur Respir J 2003; 22: Suppl. 45, 148s
Year: 2003
Cardiopulmonary stress test: Desterminations of oxygen consumption, power and cardiac variables at ventilatory threshold. Correlation with values at maximal exercise in COPD
Source: Annual Congress 2011 - Clinical physiology for clinical problems
Year: 2011
Cardiac index by thermodilution and from non-invasive pulse pressure profiles analysis in PAH
Source: Annual Congress 2012 - Pulmonary circulation: clinical diagnosis, treatment, end-points and animal models
Year: 2012
Exercise oxygen uptake efficiency slope independently predicts poor outcome in pulmonary arterial hypertension
Source: Eur Respir J 2014; 43: 1510-1512
Year: 2014
Discriminating features of responses in cardiopulmonary exercise testing
Source: ISSN=ISSN 1025-448x, ISBN=ISBN 978-1-904097-49-5, page=36
Year: 2007
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept