Development of an in-vitro model for aerosol sizing at 37°C and 100% relative humidity

C. Majoral, A. L. Coates, P. Diot, A. Le Pape, L. Vecellio (Tours, France)

Source: Annual Congress 2006 - Assessing the lungs in obstruction: technological advances in lung function testing
Session: Assessing the lungs in obstruction: technological advances in lung function testing
Session type: Thematic Poster Session
Number: 4171
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
C. Majoral, A. L. Coates, P. Diot, A. Le Pape, L. Vecellio (Tours, France). Development of an in-vitro model for aerosol sizing at 37°C and 100% relative humidity. Eur Respir J 2006; 28: Suppl. 50, 4171

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Optimization of inhalation treatment – Assessment of the influence of diluent and air humidity on particle distribution of colistin administered by BCTS method [bronchial control treatment system]
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010


A portable device capable to deliver to the airways filtered air with a submicrometric particle removal efficiency up to 90%
Source: Annual Congress 2010 - Occupational and environmental exposures and respiratory disease
Year: 2010


A portable device capable to ensure a good air quality inside a rain covered baby carriage with a particle removal efficiency up to 90%
Source: Annual Congress 2010 - Outdoor air pollution
Year: 2010


Air quality evaluation in a pulmonary unit room using a portable volumetric sampler for airborne particles (PARTRAP FA 52)
Source: Eur Respir J 2001; 18: Suppl. 33, 141s
Year: 2001

Effect of temperature and storage on endotoxin detection in reservoir dust sample
Source: Eur Respir J 2002; 20: Suppl. 38, 518s
Year: 2002

Effect of air and heliox as carrier gas on CO2 diffusion in a model of high frequency oscillation comparing two oscillators
Source: Eur Respir J 2001; 18: Suppl. 33, 456s
Year: 2001

Effects of outdoor temperature and humidity on methacholine challenge tests
Source: Annual Congress 2011 - Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Year: 2011


The influence of inhalation flow and aerosol size on deposition: modelled vs. clinical data
Source: Virtual Congress 2020 – Asthma inhalers: devices and adherence studies
Year: 2020


Optimization of inhalation treatment – Evaluation of influence of spacer integrated with the spirometer on aerosol particle distribution from pMDI-EB
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010


O2 as sweep gas shows slightly more effective decarboxylation compared to air in an in-vitro ECCO2R test setup
Source: International Congress 2019 – ECMO, ECCO2R and other rescue therapies in acute respiratory failure
Year: 2019


Off-line measurements of exhaled NO with a new constant-low-flow device in children 4-7 years: influence of ambient NO and inhalation of NO-free air
Source: Eur Respir J 2001; 18: Suppl. 33, 40s
Year: 2001

Audit of inter-spirometer reproducibility of FEV1 in 4 spirometers over 20 measurement days. Observation of variability in FEV1 in a normal subject over 20 measurement days
Source: Eur Respir J 2007; 30: Suppl. 51, 180s
Year: 2007

Effects on the respirable dose < 3.3 µm of an isotonic DSCG inhalation solution (IsoCROM) comparing different nebuliser systems mimicking 3 year old childrens' breathing patterns
Source: Eur Respir J 2007; 30: Suppl. 51, 460s
Year: 2007

Reliability of aerosol output from a devilbiss 45 nebuliser
Source: Eur Respir J 2003; 22: Suppl. 45, 472s
Year: 2003

Co-cultures of multiple cell types mimic pulmonary cell communication in response to urban PM10
Source: Eur Respir J 2008; 32: 1184-1194
Year: 2008



Effect of 3 different nebulisers on the aerosol delivery performance of isotonic disodium comoglycate (IsoCROM)
Source: Eur Respir J 2006; 28: Suppl. 50, 212s
Year: 2006

Environmental temperature and relative humidity influence exhaled breath condensate pH
Source: Eur Respir J 2008; 31: 474-475
Year: 2008


Effect of I:E ratio on the respirable delivered dose from nebulizers
Source: Virtual Congress 2020 – Experimental and laboratory studies in intensive care unit medicine
Year: 2020


Use of a heated SpO2-PCO2 single sensor: comparison of results versus arterial blood gas measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 185s
Year: 2004

Airways changes related to air pollution exposure in wheezing children
Source: Eur Respir J 2012; 39: 246-253
Year: 2012