Optimization of inhalation treatment – Evaluation of influence of spacer integrated with the spirometer on aerosol particle distribution from pMDI-EB

Z. Podolec, J. Siekaniec (Cracow, Poland)

Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Session: Drug delivery and pharmacokinetics I
Session type: E-Communication Session
Number: 2029
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Z. Podolec, J. Siekaniec (Cracow, Poland). Optimization of inhalation treatment – Evaluation of influence of spacer integrated with the spirometer on aerosol particle distribution from pMDI-EB. Eur Respir J 2010; 36: Suppl. 54, 2029

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Optimization of inhalation treatment – Evaluation of influence of PNEUMOlogic® and Optimiser® spacers on aerosol particle distribution from pMDI-EB
Source: Annual Congress 2011 - Drug delivery and pharmacokinetics I
Year: 2011


Optimization of inhalation treatment – Assessment of the influence of diluent and air humidity on particle distribution of colistin administered by BCTS method [bronchial control treatment system]
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010


Effective and efficient nebulization of alpha1-proteinase inhibitor (alpha1-PI) for inhalation therapy using the AKITA2® APIXNEBÔ nebulizer system
Source: Annual Congress 2010 - Drug delivery and pharmacokinetics I
Year: 2010


Comparative in vitro performance of a new re-usable breath-actuated nebulizer (BAN) with other high performance systems intended for domiciliary use – 2: Portable battery-compressor
Source: Annual Congress 2012 - The best of pharmacology treatments of airway diseases: new devices and drugs
Year: 2012


Comparative in vitro performance of a new re-usable breath-actuated nebulizer (BAN) with other high performance systems intended for domiciliary use – 1: Table-top compressors
Source: Annual Congress 2012 - Translational respiratory medicine in asthma and COPD
Year: 2012


Endogenous particles in exhaled air – Variability of particle number in healthy individuals
Source: Annual Congress 2012 - Airway diseases: from invasive to noninvasive biomarkers
Year: 2012


Effect of nebuliser position on aerosol performance during high flow nasal therapy
Source: International Congress 2018 – New tools for managing respiratory failure
Year: 2018


Particle size and gravimetric characteristics of Clenny Aerosol, a new jet nebulizer with breath enhanced bulb
Source: Eur Respir J 2001; 18: Suppl. 33, 99s
Year: 2001

LATE-BREAKING ABSTRACT: Effect of inhalation profiles and throat geometries on predicted lung deposition of budesonide and formoterol (BF) when inhaled through two different devices
Source: International Congress 2014 – Innovative technology and techniques in respiratory function
Year: 2014


Effect of 3 different nebulisers on the aerosol delivery performance of isotonic disodium comoglycate (IsoCROM)
Source: Eur Respir J 2006; 28: Suppl. 50, 212s
Year: 2006

Effect of I:E ratio on the respirable delivered dose from nebulizers
Source: Virtual Congress 2020 – Experimental and laboratory studies in intensive care unit medicine
Year: 2020


The influence of inhalation flow and aerosol size on deposition: modelled vs. clinical data
Source: Virtual Congress 2020 – Asthma inhalers: devices and adherence studies
Year: 2020


Effect of antistatic AeroChamber Plus® Flow-Vu® spacer on the systemic bioavailability of CHF5993 a novel triple pMDI
Source: International Congress 2016 – Pulmonary drug delivery
Year: 2016


Comparison of aerosol delivery of AccuMist and AeroEclipse II using a breath simulator
Source: Virtual Congress 2020 – Novel findings in intensive care unit medicine: part 1
Year: 2020


Delivery of medication by breath-actuated nebulizer (BAN) is similar when used with differing inhalation / exhalation ratios: A contrast to breath enhanced nebulizer (BEN) behavior
Source: International Congress 2014 – Respiratory symptoms in primary care populations
Year: 2014

Aerosol particle size output from a new nebuliser system, measured by cascade impaction
Source: Eur Respir J 2005; 26: Suppl. 49, 125s
Year: 2005

Median mass aerodynamic diameter (MMAD) and fine particle fraction (FPF): Influence on lung deposition?
Source: International Congress 2014 – Asthma and COPD devices and treatments
Year: 2014


Lung targeting of flunisolide is enhanced when delivered as an extra fine HFA aerosol with a built-in spacer
Source: Eur Respir J 2001; 18: Suppl. 33, 70s
Year: 2001