Blood gas parameters at exercise are more sensitive for lung involvement in patients with SSc than DLCO

R. Kriz, K. Vonbank, K. Krenn, B. Marzluf, V. Petkov, L. H. Block (Austria)

Source: Annual Congress 2010 - Gas exchange and paediatric exercise testing
Session: Gas exchange and paediatric exercise testing
Session type: Thematic Poster Session
Number: 888
Disease area: Interstitial lung diseases, Pulmonary vascular diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
R. Kriz, K. Vonbank, K. Krenn, B. Marzluf, V. Petkov, L. H. Block (Austria). Blood gas parameters at exercise are more sensitive for lung involvement in patients with SSc than DLCO. Eur Respir J 2010; 36: Suppl. 54, 888

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Exercise limitation in patients with interstitial lung disease independent from diffusion capacity (DLCO)
Source: Annual Congress 2008 - Exercise: system responses
Year: 2008


Static lung compliance and DLCO often demonstrate parenchymal involvement in sarcoidosis despite a normal total lung capacity
Source: Annual Congress 2009 - Sarcoidosis in review
Year: 2009

Gas exchange impairment under incremental exercise in sarcoidosis patients with normal resting pulmonary functions
Source: Annual Congress 2008 - Pulmonary mechanics and gas exchange
Year: 2008


Static lung compliance (Cst) and diffusion lung capacity (DLCO) as markers of lung function impairment in sarcoid patients with normal lung volumes
Source: Eur Respir J 2003; 22: Suppl. 45, 278s
Year: 2003

Low DLCO, reduced pulmonary blood volume and ventilatory inefficiency in smokers with mild emphysema
Source: Virtual Congress 2021 – New insights into the pathophysiology and prognosis of COPD
Year: 2021



Quality of spirometry and diffusion of the lung (DLCO) data in patients with systemic sclerosis.
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


The diagnostic value of volumetric capnography in patients with COPD and pulmonary gas exchange dysfunction
Source: Annual Congress 2007 - Exercise: measurements, techniques and paradigms
Year: 2007


Flow-volume parameters in COPD related to extended measurements of lung volume, diffusion and resistance
Source: Annual Congress 2013 –Lung function tests to monitor airway diseases
Year: 2013


Diffusing capacity of the lung for carbon monoxide (DLCO) and pulmonary blood flow during incremental and intermittent-work exercise tests
Source: Annual Congress 2008 - Pulmonary mechanics and gas exchange
Year: 2008


Ventilation heterogeneity in COPD and healthy smokers relates to diffusion capacity, resistance and reactance
Source: International Congress 2015 – Monitoring airway diseases with lung function tests
Year: 2015


Enoxaparin elicits an effect on lung function and blood gas levels in patients with COPD
Source: Eur Respir J 2004; 24: Suppl. 48, 342s
Year: 2004

Measurement of pulmonary gas-exchange function at rest and during exercise
Source: Annual Congress 2007 - PG2 - Respiratory physiology: pulmonary gas transfer and arterial blood gases
Year: 2007



Lung volumes, diffusing capacity and static lung compliance in patients with UIP pattern of IPF
Source: Eur Respir J 2002; 20: Suppl. 38, 62s
Year: 2002

The role of spirometry and ?arbon monoxide diffusing capacity (DLCO) in the diagnosis of pulmonary function in patients after COVID-19 pneumonia
Source: Virtual Congress 2021 – Pulmonary rehabilitation in the COVID-19 era
Year: 2021


The trend of pulmonary function tests over time in COPD patients with different levels of blood eosinophils
Source: International Congress 2016 – Biomarkers and phenotypes of COPD
Year: 2016

Pulmonary function testing parameters and exercise capacity in subjects with scleroderma
Source: Annual Congress 2008 - Interstitial lung disease in systemic and vascular disorders
Year: 2008

Alcohol effects on diffusing capacity of the lung for carbon monoxide (DLCO) in healthy subjects and in COPD patients
Source: Annual Congress 2010 - Exercise in respiratory diseases and oxygen therapy
Year: 2010

COPD patients have reduced bronchial blood flows
Source: Eur Respir J 2004; 24: Suppl. 48, 112s
Year: 2004

Resting DLCO predictis exercise lung gas exchange efficiency but not walking distance at 6‘WT in idiopathic pulmonary artery hypertension (IPAH)
Source: Eur Respir J 2005; 26: Suppl. 49, 106s
Year: 2005

Temporal effects of analysis delay in arterial blood gas samples in patients with COPD exacerbations and healthy controls
Source: Annual Congress 2009 - Comorbidities and case management in primary respiratory care
Year: 2009