The concentration of hydrogen peroxide in exhaled breath condensate (EBC) depends on food intake and increases during the day

H. Knobloch, G. Becher, M. Decker, P. Reinhold (Jena, Berlin, Germany)

Source: Annual Congress 2006 - Breath of life: assessing inflammation and obstruction in airways disease
Session: Breath of life: assessing inflammation and obstruction in airways disease
Session type: Thematic Poster Session
Number: 1632
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
H. Knobloch, G. Becher, M. Decker, P. Reinhold (Jena, Berlin, Germany). The concentration of hydrogen peroxide in exhaled breath condensate (EBC) depends on food intake and increases during the day. Eur Respir J 2006; 28: Suppl. 50, 1632

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Exercise increases the hydrogen peroxide release in exhaled breath condensate
Source: Annual Congress 2012 - Exhaled biomarkers in airway diseases
Year: 2012

Sampling time is important for the collection of hydrogen peroxide in exhaled breath condensate (EBC)
Source: Eur Respir J 2003; 22: Suppl. 45, 78s
Year: 2003

Use of sodium and potassium as dilution markers in the assessment of hydrogen peroxide in exhaled breath condensate (EBC)
Source: Eur Respir J 2005; 26: Suppl. 49, 577s
Year: 2005

Hydrogen peroxide ( H2O2 )in exhaled breath condensate can be affected by mouthwash and pH
Source: Eur Respir J 2003; 22: Suppl. 45, 448s
Year: 2003

Quantitative analysis of 8-isoprostane and hydrogen peroxide in exhaled breath condensate
Source: Eur Respir J 2004; 23: 189-192
Year: 2004



The markers of free radical oxidation in exhaled breath condensate (EBC) during the long-term smoking
Source: Annual Congress 2009 - Tobacco smoke and inflammatory and immune effects
Year: 2009

Within the exhaled breath condensate (EBC), nitrite and LTB4 are correlated to each other when calculated per 100 litres exhaled breath
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

The airways are the main source of hydrogen peroxide in exhaled breath condensate
Source: Annual Congress 2010 - Exhaled biomarkers: smells like disease
Year: 2010

The concentration of total protein in exhaled breath condensate (EBC) depends on various variables of ventilation
Source: Eur Respir J 2006; 28: Suppl. 50, 283s
Year: 2006

Influence of sampling time on malondialdehyde levels and pH in exhaled breath condensate
Source: Eur Respir J 2003; 22: Suppl. 45, 38s
Year: 2003

Increased lactate concentrations in exhaled breath condensate (EBC) in COPD
Source: Eur Respir J 2007; 30: Suppl. 51, 584s
Year: 2007

Short-term variation and influence of a nose clip on nitrite (NI) and nitrate (NA) levels in the exhaled breath condensate (EBC)
Source: Eur Respir J 2003; 22: Suppl. 45, 267s
Year: 2003

Exhaled breath condensate: hydrogen peroxide
Source: Eur Respir Monogr 2010; 49: 162-172
Year: 2010


The dynamic of pH, hydrogen peroxide and nitrite in exhaled breath condensate from patients with COPD and asthma exacerbation
Source: Annual Congress 2010 - COPD: treatment and monitoring
Year: 2010

Influence of smoking on indicators of free-radical oxidation in a condensate in exhaled breath condensate (EBC) at healthy and patients with bronchial asthma (BA)
Source: Annual Congress 2010 - Smoking related disorders
Year: 2010

In exhaled breath condensate pH-value correlates with ammonium concentration
Source: Eur Respir J 2003; 22: Suppl. 45, 280s
Year: 2003

The dynamics of free radical parameters in exhaled breath condensate (EBC) in smokers during the course of physical workload
Source: Annual Congress 2011 - Smoking-related diseases and smoking cessation
Year: 2011

Concentrations of the hydrogen peroxide and nitrite in exhaled breath condensate as markers of inflammatory lung diseases
Source: Annual Congress 2008 - COPD
Year: 2008

The coating of condenser systems influences the detection of 8-isoprostane in exhaled breath condensate (EBC)
Source: Eur Respir J 2004; 24: Suppl. 48, 468s
Year: 2004