Within-day repeatability and signal to noise ratio for IOS parameters and FEV1 in smokers with and without COPD

B. Aarli, R. Jensen, T. Eagan, P. Calverley, P. Bakke, J. Hardie (Bergen, Norway; Salt Lake City, United States Of America; Liverpool, United Kingdom)

Source: Annual Congress 2009 - Functional insights into COPD
Session: Functional insights into COPD
Session type: Thematic Poster Session
Number: 3812
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
B. Aarli, R. Jensen, T. Eagan, P. Calverley, P. Bakke, J. Hardie (Bergen, Norway; Salt Lake City, United States Of America; Liverpool, United Kingdom). Within-day repeatability and signal to noise ratio for IOS parameters and FEV1 in smokers with and without COPD. Eur Respir J 2009; 34: Suppl. 53, 3812

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Multiple breath washout (MBW): within-test repeatability and short-term reproducibility of FRC and lung clearance index (LCI) in healthy children and adolescents
Source: Annual Congress 2008 - Diagnostic paediatric lung function: technical and clinical aspects
Year: 2008

The value of FENO50 measurement in COPD – results from the TIE-study
Source: International Congress 2017 – Current challenges in COPD evaluation
Year: 2017

Accuracy for DLco impairment through ventilatory efficiency indices in smokers without COPD.
Source: Virtual Congress 2021 – Lung function evaluation and assessment of airway diseases
Year: 2021


Comparison of sensitivity and variability of sGaw and FEV1 for measuring bronchodilation in healthy and asthmatic subjects
Source: Eur Respir J 2004; 24: Suppl. 48, 338s
Year: 2004

FEV1 and respiratory resistance response to methacholine in children calculated from between-measurement variability
Source: Eur Respir J 2005; 26: Suppl. 49, 43s
Year: 2005

Measurement duration impacts variability but not impedance measured by the forced oscillation technique in healthy, asthma and COPD subjects
Source: ERJ Open Res 2016: 00094-2015
Year: 2016



The relationship between long-term correlations (self-similarity) in PEF and FEV1 in COPD
Source: Annual Congress 2012 - New issues in pulmonary function
Year: 2012

FEV6 and FEV1/FEV6 have higher association with small airway function and oxygen saturation than FVC and FEV1/FVC in patients with asthma.
Source: Virtual Congress 2020 – Lung function tests and exhaled biomarkers
Year: 2020

Repeatability study comparing plethysmographic and spirometric lung function parameters in COPD patients, asthmatics, and healthy subjects
Source: Eur Respir J 2006; 28: Suppl. 50, 221s
Year: 2006

Comparation of plethysmographic and diffusion parameters of hyperinflation in children with asthma
Source: Eur Respir J 2003; 22: Suppl. 45, 495s
Year: 2003

Variation of FEV1 vs reactance and resonant frequency by forced oscillation technique during methacholine challenge in asthmatics
Source: Eur Respir J 2005; 26: Suppl. 49, 374s
Year: 2005

Pre- and post-bronchodilator spirometric values and the degree of reversibility in patients with COPD
Source: Eur Respir J 2004; 24: 332
Year: 2004


Spirometric data quality as assessed by repeatability in COPD exacerbations
Source: Annual Congress 2012 - Going with the flow: assessment and evaluation of airway function and its role in patient management
Year: 2012


Within session variability of FEV1 and FVC pre- and post-bronchodilation
Source: International Congress 2019 – Quality, performance and interpretation of lung function testing
Year: 2019


FEV1/FEV6 versus FEV1/FVC in the spirometric detection of airway obstruction among Asians
Source: Annual Congress 2007 - Current issues in airway physiology, pharmacology and monitoring
Year: 2007


Reproducibility and repeatability of tidal breathing parameters derived from structured light plethysmography when compared to spirometry
Source: Annual Congress 2011 - Lung and airway function
Year: 2011


Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry
Source: Eur Respir J 2008; 32: 1262-1268
Year: 2008



Duration and frequency of spirometry needed to accurately reflect longitudinal change of FEV1 in COPD
Source: Virtual Congress 2021 – Lung function testing in the management of obstructive diseases
Year: 2021


Using the pre-bronchodilator spirometry curvature to improve estimation of post-bronchodilator airflow obstruction
Source: International Congress 2019 – Physiologic assessment of airway diseases
Year: 2019


Repeatability and reproducibility of the lung clearance index (LCI) in healthy adolescents
Source: Annual Congress 2007 - Crossroads between paediatric respiratory physiology and epidemiology
Year: 2007