Coupling of noninvasive mechanical ventilation and nebulization during asthma exacerbations: higher amount of aerosol deposition into the airways or effective mechanical brochodilation due to positive pressure?

V. Galindo Filho, M. D. G. Rodrigues Machado, D. Brandão, L. Alcoforado, A. M. Galvão, G. Fregonezi, P. Marinho, E. Dean, A. Dornelas de Andrade (Recife, Belo Horizonte, Natal, Brazil; Vacouver, Canada)

Source: Annual Congress 2009 - Treatment modalities in chest physiotherapy
Session: Treatment modalities in chest physiotherapy
Session type: Thematic Poster Session
Number: 2292
Disease area: Airway diseases, Respiratory critical care

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
V. Galindo Filho, M. D. G. Rodrigues Machado, D. Brandão, L. Alcoforado, A. M. Galvão, G. Fregonezi, P. Marinho, E. Dean, A. Dornelas de Andrade (Recife, Belo Horizonte, Natal, Brazil; Vacouver, Canada). Coupling of noninvasive mechanical ventilation and nebulization during asthma exacerbations: higher amount of aerosol deposition into the airways or effective mechanical brochodilation due to positive pressure?. Eur Respir J 2009; 34: Suppl. 53, 2292

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Effects from nebulisation associated to noninvasive mechanical ventilation in acute asthma
Source: Annual Congress 2007 - Critical care and airways clearance
Year: 2007


Noninvasive positive pressure ventilation in acute asthmatic attack
Source: Eur Respir Rev 2009; 19: 39-45
Year: 2010



Jet nebulization associated to noninvasive mechanical ventilation (NMV): pulmonary deposition pattern of inhaled radioaerossol
Source: Eur Respir J 2004; 24: Suppl. 48, 407s
Year: 2004

Comparison of response to aerosol drug delivery with mesh and jet nebulizers during non-invasive ventilation (NIV) in acute exacerbation of COPD.
Source: International Congress 2017 – Clinical and physiological challenges in noninvasive ventilation
Year: 2017


Changes in airway and tissue mechanics in ventilated COPD patients after nebulized bronchodilator agent
Source: Annual Congress 2007 - Advances in respiratory mechanics
Year: 2007


Use of continuous positive airway pressure reduces airway reactivity in adults with asthma
Source: Eur Respir J 2013; 41: 317-322
Year: 2013



Noninvasive ventilation in infants with severe upper airway obstruction: continuous or bilevel positive airway pressure ventilation?
Source: Eur Respir J 2003; 22: Suppl. 45, 401s
Year: 2003

Bronchodilators delivery during mechanical ventilation
Source: Annual Congress 2007 - Bronchodilator delivery during mechanical ventilation
Year: 2007

Artificial lung as an alternative to mechanical ventilation in COPD exacerbation
Source: Eur Respir J 2011; 39: 212-215
Year: 2012


Artificial lung as an alternative to mechanical ventilation in COPD exacerbation
Source: Eur Respir J 2012; 39: 212-215
Year: 2012


Sputum microbial pattern in severe exacerbations of COPD requiring non-invasive mechanical ventilation
Source: Eur Respir J 2004; 24: Suppl. 48, 312s
Year: 2004

Lung perfusion and ventilation modifications induced by nasal non-invasive positive pressure ventilation (nNPPV) in patients with CRF due to severe COPD
Source: Eur Respir J 2002; 20: Suppl. 38, 625s
Year: 2002

COPD with and without exacerbation: comparison of respiratory mechanics during mechanical ventilation
Source: Eur Respir J 2006; 28: Suppl. 50, 393s
Year: 2006

Airway dynamics in COPD patients by within-breath impedance tracking: effects of continuous positive airway pressure
Source: Eur Respir J , 49 (2) 1601270; DOI: 10.1183/13993003.01270-2016
Year: 2017



Effect of non-invasive ventilation on bronchodilator delivery
Source: Annual Congress 2005 - Non-invasive ventilation: what's new?
Year: 2005


Application of noninvasive ventilation in patients with acute hypercapnic exacerbation of chronic respiratory failure: our experience on use of negative pressure ventilation and noninvasive intermittent positive pressure ventilation
Source: Eur Respir J 2001; 18: Suppl. 33, 29s
Year: 2001

Aerosol vs. nebulisation: comparison of two methods of salbutamol administration in AECB hypercapnic respiratory failure requiring NIMV
Source: Annual Congress 2005 - Non-invasive ventilation: what's new?
Year: 2005


Ineffective efforts during nightime non-invasive mechanical ventilation in COPD or RTD patients
Source: Annual Congress 2005 - Non-invasive ventilation: what's new?
Year: 2005


Respiratory mechanics 1: physiological bases of monitoring airway pressures during mechanical ventilation
Source: International Congress 2015 – PG3 Cardiorespiratory monitoring in critically ill patients
Year: 2015




Air stacking, cough machine – in/exsufflator, high frequency oscillation and intrapulmonary percussive ventilation
Source: Annual Congress 2005 - Management of airway hypersecretions
Year: 2005