Impulse oscillometry parameters of COPD patients during inspiration and expiration and the effect of tiotropium inhalation therapy

H. Kobayashi, M. Kubota, G. Shirai, T. Shinbo, K. Kokubo, M. Hirose, N. Masuda (Sagamihara/kanagawa, Japan)

Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing
Session: Beyond spirometry: the skills behind lung function testing
Session type: Thematic Poster Session
Number: 2185
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
H. Kobayashi, M. Kubota, G. Shirai, T. Shinbo, K. Kokubo, M. Hirose, N. Masuda (Sagamihara/kanagawa, Japan). Impulse oscillometry parameters of COPD patients during inspiration and expiration and the effect of tiotropium inhalation therapy. Eur Respir J 2008; 32: Suppl. 52, 2185

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Effect of He-O2 breathing and inhaled salbutamol on expiratory flow limitation and dynamic hyperinflation in COPD patients
Source: Eur Respir J 2002; 20: Suppl. 38, 197s
Year: 2002

Differentiation of bronchodilator effects of indacaterol and formoterol by FEV1 and inspiratory capacity (IC) in patients with COPD
Source: Annual Congress 2007 - New drugs for COPD
Year: 2007



Evaluation of the response of airway obstruction to short-acting inhaled broncodilators with using FIV1 and FEV1 in COPD patients
Source: Eur Respir J 2005; 26: Suppl. 49, 290s
Year: 2005

Efficacy of Flutter® and forced expiration technique (FET) in induced sputum assessment in asthmatic and COPD patients
Source: Annual Congress 2008 - Asthma: growing understanding of influential factors
Year: 2008

Impulse oscillometry provides an effective measure of bronchodilator responses in patients with COPD
Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing
Year: 2008


Bronchodilator acutely reduces expiratory flow limitation during exercise in COPD demonstrated by dynamic hyperinflation, flow-volume curve analysis and impulse oscillometry
Source: Virtual Congress 2020 – From respiratory physiology to diagnosis and treatment
Year: 2020


Evaluation of a guided breathing manoeuvre for nebulised drug delivery in COPD patients
Source: Eur Respir J 2004; 24: Suppl. 48, 581s
Year: 2004

Effect of inhaled bronchodilators on inspiratory capacity and dyspnoea at rest in COPD
Source: Eur Respir J 2003; 21: 86-94
Year: 2003



Improvements in inspiratory capacity with tiotropium in patients with COPD
Source: Eur Respir J 2002; 20: Suppl. 38, 491s
Year: 2002

Effects of expiratory positive airway pressure on exercise dynamic hyperinflation in COPD patients
Source: Annual Congress 2010 - Noninvasive ventilation: technical, logistical and organisational aspects
Year: 2010

Non-contact assessment of acute bronchodilator’ response during tidal breathing in COPD patients using structured light plethysmography (SLP)
Source: International Congress 2015 – Lung function: new findings and approaches
Year: 2015

Comparison of sensitivity of impulse oscillometry, plethysmography and spirometry for measuring bronchodilation in asthma
Source: Eur Respir J 2003; 22: Suppl. 45, 100s
Year: 2003

Peak expiratory flow use for screening airflow obstruction and monitoring the bronchodilator effect in COPD patients in primary care settings
Source: Eur Respir J 2006; 28: Suppl. 50, 738s
Year: 2006

Using of impulse oscillometry in bronchodilatation response evaluation in patients with chronic cough
Source: Annual Congress 2008 - Lung function, airways and cough
Year: 2008


Bronchodilator reversibility testing in COPD using an inspiratory peak flow meter
Source: Annual Congress 2007 - Treatment of COPD
Year: 2007


Assessment of ventilation heterogeneity by impulse oscillometry in patients with mild asthma
Source: Annual Congress 2012 - Lung function tests in monitoring airway diseases
Year: 2012


Evaluation of lung function and deposition in the nebulization carried by heliox associated with positive end expiratory pressure in stable asthmatics: Clinical trial
Source: Annual Congress 2011 - Asthma: issues in rehabilitation and physical therapy
Year: 2011

Impulse oscillometry parameters in patients with COPD and asthma with severe ventilation disorders
Source: Eur Respir J 2003; 22: Suppl. 45, 99s
Year: 2003

Airways dilate to simulated inspiratory but not expiratory manoeuvres
Source: Eur Respir J 2012; 40: 455-461
Year: 2012



Disturbing effect of pattern of inspiratory manoeuvre preceding forced expiration on PEF monitoring in self-management of asthma
Source: Eur Respir J 2005; 26: Suppl. 49, 507s
Year: 2005