Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical analyzer and ecomedics chemoluminescence analyzer

J. D. Boot, L. de Ridder, M. de Kam, A. F. Cohen, Z. Diamant (Leiden, Netherlands)

Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Session: Clinical utility of exhaled nitric oxide measurement
Session type: Thematic Poster Session
Number: 1123
Disease area: Airway diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
J. D. Boot, L. de Ridder, M. de Kam, A. F. Cohen, Z. Diamant (Leiden, Netherlands). Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical analyzer and ecomedics chemoluminescence analyzer. Eur Respir J 2008; 32: Suppl. 52, 1123

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Exhaled nitric oxide measured by using NIOX MINO and chemo-luminescence analyser: a comparative study
Source: Eur Respir J 2007; 30: Suppl. 51, 365s
Year: 2007

Comparisons between portable and chemoluminescence exhaled nitric oxide measurements
Source: Eur Respir J 2008; 32: 243-244
Year: 2008


Comparison of fractional exhaled nitric oxide (FeNO) levels measurements between now portable analyzer and stationary analyzer
Source: Annual Congress 2010 - Biomarkers and Diagnosis of asthma and allergic respiratory diseases
Year: 2010

Intra-device repeatability of the NIOX-MINO handheld fractional exhaled nitric oxide monitor.
Source: International Congress 2019 – Asthma biomarkers, diagnostics and risk factors
Year: 2019


Exhaled nitric oxide measurement with portable analyser in COPD
Source: Eur Respir J 2007; 30: Suppl. 51, 366s
Year: 2007

A comparison of two analysers measuring exhaled nitric oxide concentration
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

Correction equation to compare exhaled nitric oxide measured by a portable analyzer to that obtained by the gold-standard device
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


HypAir FeNO: an electrochemical sensor
Source: Eur Respir J, 51 (4) 1800164; 10.1183/13993003.00164-2018
Year: 2018



Reliability of a new portable device for the measurement of fractional exhaled nitric oxide (FeNO)
Source: Annual Congress 2010 - Innovations in the assessment of airway diseases
Year: 2010


Measurement of exhaled nitric oxide: comparison of 3 different analyzers
Source: International Congress 2018 – Biomarkers for evaluating asthma
Year: 2018

Comparison of diagnostic accuracy between the chemiluminescence and electrochemical methods for nasal nitric oxide measurements in PCD
Source: International Congress 2018 – Insights in primary ciliary dyskinesia, asthma and lung function testing
Year: 2018


Reproducibility of the Vivatmopro measurements for exhaled nitric oxide values
Source: International Congress 2019 – Insights into physiological diagnostic services
Year: 2019


Comparison of fractional exhaled nitric oxide (FeNO) levels measured by different analysers
Source: International Congress 2018 – Biomarkers for evaluating asthma
Year: 2018

The agreement between online and offline measurement of exhaled nitric oxide
Source: Eur Respir J 2001; 18: Suppl. 33, 39s
Year: 2001

Reproducibility of exhaled nitric oxide (NO) measured by multiple exhalation flow technique (MEFT) in adults
Source: Eur Respir J 2003; 22: Suppl. 45, 279s
Year: 2003

Feasibility and repeatability of fractional exhaled nitric oxide (FENO) measurements using a new hand-held NO monitoring device in general practice
Source: Eur Respir J 2006; 28: Suppl. 50, 791s
Year: 2006

Exhaled nitric oxide measured by a new hand-held device in clinical practice
Source: Annual Congress 2008 - Clinical utility of exhaled nitric oxide measurement
Year: 2008


Is the portable NIOX MINO reliable for screening nasal nitric oxide levels in primary ciliary dyskinesia?
Source: Annual Congress 2012 - Going with the flow: assessment and evaluation of airway function and its role in patient management
Year: 2012

Effect of a sequential exhalation flow method on exhaled nitric oxide measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 340s
Year: 2004

Comparison of measurements of exhaled nitric oxide (FeNO) by NIOX MINO and FenoMedisoft® in a paediatric population from 6 to 16 years old
Source: Annual Congress 2009 - FeNO and other biomarkers in childhood asthma
Year: 2009