Alkaline mineral water inhalation causes permanent alkalization of exhaled breath condensate

B. Szili, A. Bikov, B. Antus, A. Zsembery, M. Kollai, I. Horváth (Budapest, Hungary)

Source: Annual Congress 2008 - Inflammatory biomarkers
Session: Inflammatory biomarkers
Session type: Thematic Poster Session
Number: 1109
Disease area: Airway diseases, Paediatric lung diseases

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
B. Szili, A. Bikov, B. Antus, A. Zsembery, M. Kollai, I. Horváth (Budapest, Hungary). Alkaline mineral water inhalation causes permanent alkalization of exhaled breath condensate. Eur Respir J 2008; 32: Suppl. 52, 1109

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

Andras Bikov - 07.10.2008 16:58
:)
It was a very nice job
You must Login to comment this presentation.


Related content which might interest you:
The effect of cold sterilisation, acid and alkali ingestion on exhaled breath condensate pH
Source: Annual Congress 2009 - What is new in the regulation and monitoring of airway function?
Year: 2009


In exhaled breath condensate pH-value correlates with ammonium concentration
Source: Eur Respir J 2003; 22: Suppl. 45, 280s
Year: 2003

Keratin detected in exhaled breath condensate is an environmental contaminant
Source: Annual Congress 2005 - Airway epithelial cells in asthma and COPD
Year: 2005


Exhaled breath condensate (EBC): changes in magnesium, pH and conductivity after exposure to swine house dust or inhaled LPS
Source: Eur Respir J 2005; 26: Suppl. 49, 734s
Year: 2005

The pH-value of exhaled breath condensate - mainly influenced by exhaled volatile compounds
Source: Eur Respir J 2005; 26: Suppl. 49, 373s
Year: 2005

Rapid measurement of lactate in exhaled breath condensate
Source: Eur Respir J 2006; 28: Suppl. 50, 435s
Year: 2006

Effect of isocapnic hyperventilation with cold air on breath condensate volume and LTB4-concentration in breath condensate
Source: Eur Respir J 2002; 20: Suppl. 38, 411s
Year: 2002

Separate lung exhaled breath condensate collection confirms intrapulmonary origin of exhaled breath condensate acidification
Source: Eur Respir J 2007; 30: Suppl. 51, 364s
Year: 2007

Do we require de-aeration of exhaled breath condensate samples for measuring pH
Source: Virtual Congress 2020 – Unusual tools for evaluating obstructive diseases
Year: 2020

Exhaled breath condensate total NOx in chronic lung disease in response to changes in ambient air pollution
Source: Annual Congress 2007 - What's new in air pollution from experiments to epidemiology
Year: 2007



The effect of gas standardisation on exhaled breath condensate pH
Source: Eur Respir J 2006; 28: 251-252
Year: 2006


Parameters of oxidation in exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 470s
Year: 2004

Traffic-related air pollution and exhaled breath condensate (EBC) pH
Source: Annual Congress 2009 - What is new in the regulation and monitoring of airway function?
Year: 2009

Conductivity and pH in exhaled breath condensate of stable asthmatic children
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

Continuous exhaled breath condensate pH monitoring
Source: Eur Respir J 2004; 24: Suppl. 48, 27s
Year: 2004

The influence of active and passive air humidification on exhaled breath condensate volume
Source: ERJ Open Res, 6 (4) 00009-2020; 10.1183/23120541.00009-2020
Year: 2020



Copper and zinc in exhaled breath condensate of emphysema patients
Source: International Congress 2019 – Involvement of the environment and inflammation in pulmonary remodelling
Year: 2019


Changes in exhaled breath condensate pH following specific inhalation challenge in patients with occupational asthma to persulfate salts
Source: Annual Congress 2011 - Environmental exposure and disease mechanisms
Year: 2011

8-isoprostane in exhaled breath condensate (EBC) and air pollution exposure in children with wheezing
Source: Annual Congress 2012 - Indoor and outdoor air pollution
Year: 2012

Exhaled breath condensate pH standardised for CO2 partial pressure
Source: Eur Respir J 2007; 29: 496-501
Year: 2007