Cardiac output measurement by thermodilution using right heart catheter versus noninvasive rebreathing technique in pulmonary hypertension

H. J. Baumann, J. K. Hennigs, S. Kluge, H. Klose (Hamburg, Germany)

Source: Annual Congress 2008 - Pulmonary hypertension I
Session: Pulmonary hypertension I
Session type: Thematic Poster Session
Number: 1015
Disease area: Pulmonary vascular diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
H. J. Baumann, J. K. Hennigs, S. Kluge, H. Klose (Hamburg, Germany). Cardiac output measurement by thermodilution using right heart catheter versus noninvasive rebreathing technique in pulmonary hypertension. Eur Respir J 2008; 32: Suppl. 52, 1015

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Non-invasive estimation of cardiac output by impedance cardiography during incremental exercise in patients with pulmonary arterial hypertension
Source: Annual Congress 2011 - Innovative methods in exercise testing
Year: 2011

Thermodilution and Fick cardiac output measurement comparison in patients with pulmonary hypertension
Source: International Congress 2017 – Exercise and physiology in pulmonary hypertension
Year: 2017


Non-invasive measurement of stroke volume using an inert gas rebreathing device in patients with pulmonary hypertension
Source: Annual Congress 2008 - Pulmonary hypertension I
Year: 2008

The assessment of heart chambers volumes using modified transpulmonary thermodilution in patients with chronic thromboembolic pulmonary hypertension (CTEPH)
Source: Annual Congress 2008 - Pulmonary venous thromboembolic disease
Year: 2008

Noninvasive cardiac output measurements in patients with pulmonary hypertension
Source: Eur Respir J 2013; 42: 125-133
Year: 2013



Cardiac index by thermodilution and from non-invasive pulse pressure profiles analysis in PAH
Source: Annual Congress 2012 - Pulmonary circulation: clinical diagnosis, treatment, end-points and animal models
Year: 2012

Noninvasive and invasive evaluation of pulmonary arterial pressure in highlanders
Source: Eur Respir J 2007; 29: 352-356
Year: 2007



Is cardiac output assessed by inert gas rebreathing technique predictive of mortality in pulmonary hypertension?
Source: Virtual Congress 2020 – Exercise and haemodynamics in pulmonary hypertension
Year: 2020


An inert-gas rebreathing device as monitoring tool in pulmonary hypertension
Source: Annual Congress 2009 - Pulmonary vascular diseases
Year: 2009


The impact of pulmonary parameters on non-invasive measurement of cardiac output by the inert gas rebreathing method
Source: Annual Congress 2009 - Pulmonary arterial hypertension
Year: 2009


Evaluation of pulmonary arterial pressure in lung transplant candidates: transthoracic echocardiography versus right heart catheterization
Source: Annual Congress 2009 - Human and experimental lung transplantation: novel findings
Year: 2009

Telemetric right ventricular pressure measurements and serial echocardiography in experimental pulmonary arterial hypertension
Source: Annual Congress 2012 - Pulmonary circulation: clinical end-points and clinical physiology
Year: 2012

The value of tools to assess pulmonary arterial hypertension
Source: Eur Respir Rev 2011; 20: 222-235
Year: 2011



Inert gas rebreathing: the effect of pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice
Source: Annual Congress 2009 - Pulmonary vascular diseases
Year: 2009

Right heart catheterisation for assessing pulmonary exercise haemodynamics
Source: International Congress 2016 – PG17 Pulmonary haemodynamics during exercise
Year: 2016


Cardiac bioimpedance as a non-invasive tool in patients with pulmonary hypertension
Source: Annual Congress 2011 - Innovative methods in exercise testing
Year: 2011

Prediction (indirect determination) of pulmonary artery pressure by transcutaneous echo-Doppler
Source: Eur Respir J 2005; 26: Suppl. 49, 351s
Year: 2005

Comparison between transthoracic doppler echocardiography and right heart catheterization for pulmonary hypertension evaluation
Source: Annual Congress 2008 - Pulmonary vascular disease and other pulmonary conditions: miscellaneous
Year: 2008

Non-invasive hemodynamic evaluation of the pulmonary blood flow and the cardiac output in healthy subjects
Source: Annual Congress 2010 - Pulmonary venous thromboembolic disease and other pulmonary vascular disorders
Year: 2010

LATE-BREAKING ABSTRACT: Accuracy of transpulmonary thermodilution cardiac output measurement (PiCCO) in patients with right heart failure (RHF) due to precapillary pulmonary hypertension (PH)
Source: Annual Congress 2013 –Pulmonary circulation: clinical science and treatment
Year: 2013