Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques

Schmalisch G., Foitzik B., Wauer R.R., Stocks J.

Source: Eur Respir J 2001; 17: 108-114
Journal Issue: January
Disease area: Paediatric lung diseases, Respiratory critical care

Congress or journal article abstractPDF journal article, handout or slidesFull text journal article

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Schmalisch G., Foitzik B., Wauer R.R., Stocks J.. Effect of apparatus dead space on breathing parameters in newborns: "flow-through" versus conventional techniques. Eur Respir J 2001; 17: 108-114

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Dynamic dead space in face masks used with noninvasive ventilators: a lung model study
Source: Eur Respir J 2004; 23: 129-135
Year: 2004



A novel technique “slow spirometry” to estimate tidal volumes for use in AVAPS mode ventilation in children.
Source: Virtual Congress 2020 – Advances in lung function testing
Year: 2020


Reductions in dead space ventilation with nasal high flow depend on physiological dead space volume: metabolic hood measurements during sleep in patients with COPD and controls
Source: Eur Respir J, 51 (5) 1702251; 10.1183/13993003.02251-2017
Year: 2018



Inspired oxygen fraction during non-invasive ventilation: the influence of flow rates, masks, exhalation ports and ventilatory settings
Source: International Congress 2018 – Non-invasive ventilation in chronic respiratory failure
Year: 2018


In vitro assessment of equipment and software to assess tidal breathing parameters in infants
Source: Eur Respir J 2001; 17: 100-107
Year: 2001



Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Source: Eur Respir J 2002; 20: 912-918
Year: 2002



Validating manual selection of tidal breathing curves in awake infants
Source: International Congress 2019 – Evaluation of breathing in children when they are asleep, healthy or ill
Year: 2019


Dynamic hyperinflation in COPD: influence of measuring technique, breathing frequency and tidal volume
Source: Eur Respir J 2007; 30: Suppl. 51, 340s
Year: 2007

Evolution of air leaks in the adaptation period to non-invasive ventilation: a pilot study
Source: Annual Congress 2007 - Physiological effects of noninvasive ventilation
Year: 2007



Effect of manufacturer-inserted mask leaks on ventilator performance
Source: Eur Respir J 2010; 35: 627-636
Year: 2010



The effect of mouth leak on tidal volume during non-invasive ventilation
Source: Annual Congress 2003 - Physiology of NIV: understanding the effects and chosing the best settings
Year: 2003


Dynamic respiratory system mechanics in infants during pressure and volume controlled ventilation
Source: Eur Respir J 2001; 17: 115-121
Year: 2001



Influence of mask leak on applied volumes and pressures during simulated resuscitation of neonates
Source: Annual Congress 2011 - Resuscitation and ventilation in the baby and infant
Year: 2011

Relationship between air leaks and efectivity of non-invasive ventilation. A pilot study
Source: Annual Congress 2007 - Physiological effects of noninvasive ventilation
Year: 2007



Leak compensation in positive pressure ventilators: a lung model study
Source: Eur Respir J 2001; 17: 259-267
Year: 2001



Impact on inspiratory work of breathing of high- compared to low-flow continuous positive airway pressure (CPAP) delivery systems
Source: Eur Respir J 2001; 18: Suppl. 33, 504s
Year: 2001

Differences in breathing pattern variabilities measured during T-piece, automatic tube compensation and pressure support ventilation in patients with weaning success and failure
Source: Annual Congress 2008 - Diagnosis and outcome in critically ill patients
Year: 2008



NIV in the acute setting: technical aspects, initiation, monitoring and choice of interface
Source: Eur Respir Mon; 2008: 41: 173–188
Year: 2008

Feasibility of EMG measurements in neonates in comparison to conventional lung function measurements
Source: Annual Congress 2007 - Clinical applications of lung function testing in children
Year: 2007


Optimal PEEP in the first week of life in mechanically ventilated extremely preterm newborn infants: Clinical setting vs. optimal seeting as registered by forced oscillation technique (FOT)
Source: Annual Congress 2012 - Issues in neonatal and paediatric intensive care
Year: 2012