e-learning
resources
ERJ
2001
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
The infant lung function model: a mechanical analogue to test infant lung function equipment
Frey U., Reinmann B., Stocks J.
Source:
Eur Respir J 2001; 17: 755-764
Journal Issue:
April
Disease area:
Airway diseases, Respiratory critical care
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
Frey U., Reinmann B., Stocks J.. The infant lung function model: a mechanical analogue to test infant lung function equipment. Eur Respir J 2001; 17: 755-764
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Endoscopic lung volume reduction with endobronchial valves in very low DLCO patients
A modified staged treatment algorithm using the AeriSeal System
Body plethysmography
Related content which might interest you:
Assessment of an infant whole-body plethysmograph using an infant lung function model
Source: Eur Respir J 2001; 17: 765-772
Year: 2001
Plethysmographic measurements of lung volume and airway resistance
Source: Eur Respir J 2001; 17: 302-312
Year: 2001
Assessment of passive respiratory mechanics in infants: double versus single occlusion?
Source: Eur Respir J 2001; 17: 449-455
Year: 2001
In vitro assessment of equipment and software to assess tidal breathing parameters in infants
Source: Eur Respir J 2001; 17: 100-107
Year: 2001
One lung ventilation: use of the impulse oscillation system to assess lung function in an animal model
Source: Annual Congress 2008 - Assessment of the respiratory system
Year: 2008
Passive respiratory mechanics: the occlusion techniques
Source: Eur Respir J 2001; 17: 141-148
Year: 2001
How should airways resistance be measured in young children: mask or mouthpiece?
Source: Eur Respir J 2001; 17: 1244-1249
Year: 2001
Feasibility of EMG measurements in neonates in comparison to conventional lung function measurements
Source: Annual Congress 2007 - Clinical applications of lung function testing in children
Year: 2007
Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Source: Eur Respir J 2002; 20: 912-918
Year: 2002
Respiratory symptoms, lung function tests, and working ability assessment among electricians employed in power distribution facilities
Source: Annual Congress 2009 - Occupational exposures and disease II
Year: 2009
No clinical benefit for the use of respiratory system admittance to measure lung function in young children
Source: Annual Congress 2008 - Diagnostic paediatric lung function: technical and clinical aspects
Year: 2008
A portable forced oscillation device for respiratory home monitoring
Source: Eur Respir J 2002; 19: 146-150
Year: 2002
Functional residual capacity measurements in healthy infants: ultrasonic flow meter versus a mass spectrometer
Source: Eur Respir J 2004; 23: 763-768
Year: 2004
Application and interpretation in RCT's
Source: Research Seminar 2006 - Preventing respiratory sequelae in children diagnosed with cystic fibrosis by newborn screening
Year: 2006
How can we measure the impacts of pollutants on respiratory function in young children?
Source: Annual Congress 2006 - Environmental impacts on the respiratory health in children
Year: 2006
Impaired lung compliance and DL,CO but no restrictive ventilatory defect in sarcoidosis
Source: Eur Respir J 2010; 36: 1315-1322
Year: 2010
The airspace dimension test – A new way to diagnose emphysema?
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014
Is oscillometry a better metric of respiratory functional capacity compared to conventional pulmonary function tests during the first 6-months post lung transplant?
Source: International Congress 2019 – Lung transplantation: from basic science to clinical outcomes
Year: 2019
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept