Measurement of natrium chloride and adenosine concentration in exhaled breath condensate

E. Barát, E. Huszár, G. Vass, E. Csiszér, M. Valyon, I. Horváth (Budapest, Hungary)

Source: Annual Congress 2002 - Bench to bedside in lung injury
Session: Bench to bedside in lung injury
Session type: Thematic Poster Session
Number: 1792
Disease area: Airway diseases, Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
E. Barát, E. Huszár, G. Vass, E. Csiszér, M. Valyon, I. Horváth (Budapest, Hungary). Measurement of natrium chloride and adenosine concentration in exhaled breath condensate. Eur Respir J 2002; 20: Suppl. 38, 1792

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
In exhaled breath condensate pH-value correlates with ammonium concentration
Source: Eur Respir J 2003; 22: Suppl. 45, 280s
Year: 2003

Use of sodium and potassium as dilution markers in the assessment of hydrogen peroxide in exhaled breath condensate (EBC)
Source: Eur Respir J 2005; 26: Suppl. 49, 577s
Year: 2005

Determination of NO2-/NO3- level in exhaled breath condensate. Nitrate reduction with zinc
Source: Eur Respir J 2005; 26: Suppl. 49, 119s
Year: 2005

Rapid measurement of lactate in exhaled breath condensate
Source: Eur Respir J 2006; 28: Suppl. 50, 435s
Year: 2006

Within the exhaled breath condensate (EBC), nitrite and LTB4 are correlated to each other when calculated per 100 litres exhaled breath
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

Increased lactate concentrations in exhaled breath condensate (EBC) in COPD
Source: Eur Respir J 2007; 30: Suppl. 51, 584s
Year: 2007

The influence of variables of ventilation on the concentration of urea and ammonia in the exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 402s
Year: 2004

Measurement of surfactant phospholipids in exhaled breath condensate
Source: Annual Congress 2008 - Investigation, inspiration, ventilation, dedication: the essence of physiological measurement
Year: 2008

Influence of sampling time on malondialdehyde levels and pH in exhaled breath condensate
Source: Eur Respir J 2003; 22: Suppl. 45, 38s
Year: 2003

Parameters of oxidation in exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 470s
Year: 2004

Exhaled breath condensate NH4+ concentration and pH in COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 372s
Year: 2005

Exercise-induced changes in concentrations of cysteinyl-leukotrienes in exhaled breath condensate
Source: Eur Respir J 2004; 24: Suppl. 48, 680s
Year: 2004

Ammonia and urea in the exhaled breath condensate (EBC) and in corresponding blood samples
Source: Eur Respir J 2002; 20: Suppl. 38, 482s
Year: 2002

Exhaled breath condensate pH
Source: Eur Respir J 2004; 23: 961-962
Year: 2004


Do we require de-aeration of exhaled breath condensate samples for measuring pH
Source: Virtual Congress 2020 – Unusual tools for evaluating obstructive diseases
Year: 2020

The effect of gas standardisation on exhaled breath condensate pH
Source: Eur Respir J 2006; 28: 251-252
Year: 2006


Continuous exhaled breath condensate pH monitoring
Source: Eur Respir J 2004; 24: Suppl. 48, 27s
Year: 2004

Correlation of LTB4 with α-amylase in exhaled breath condensate
Source: Eur Respir J 2005; 26: Suppl. 49, 372s
Year: 2005

Exhaled nitric oxide concentration and exhaled breath condensate pH after hyperbaric oxygen exposure
Source: Eur Respir J 2006; 28: Suppl. 50, 652s
Year: 2006