Simultaneous estimation of partitioned FeNO sources and airway dimensions with tidal breath data

P. Muchmore (Los Angeles, United States of America), S. Xu (Los Angeles, United States of America), E. Rappaport (Los Angeles, United States of America), S. Eckel (Los Angeles, United States of America), F. Gilliland (Los Angeles, United States of America)

Source: International Congress 2019 – FeNO in airway diseases and asthma-COPD overlap identification
Session: FeNO in airway diseases and asthma-COPD overlap identification
Session type: Thematic Poster
Number: 2619
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
P. Muchmore (Los Angeles, United States of America), S. Xu (Los Angeles, United States of America), E. Rappaport (Los Angeles, United States of America), S. Eckel (Los Angeles, United States of America), F. Gilliland (Los Angeles, United States of America). Simultaneous estimation of partitioned FeNO sources and airway dimensions with tidal breath data. 2619

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Comparison of two devices and two breathing patterns for exhaled breath condensate sampling
Source: Annual Congress 2011 - Bronchial hyperresponsiveness and exhaled and sputum biomarkers
Year: 2011

The collection of exhaled breath condensate depends on various variables of ventilation
Source: Eur Respir J 2005; 26: Suppl. 49, 261s
Year: 2005

Validation of longitudinal, clinically applicable tidal breath exhaled NO measurements in hospitalized neonates.
Source: International Congress 2017 – NICU/ PICU: evaluating short- and long-term ventilatory management
Year: 2017

Repeated eNose assessment in the monitoring of O2-induced changes in exhaled breath metabolites in COPD
Source: Annual Congress 2008 - New frontiers in noninvasive assessment of the lungs
Year: 2008


Changes in ventilation and respiratory impedance after sampling of exhaled breath condensate (EBC) in pigs
Source: Eur Respir J 2002; 20: Suppl. 38, 175s
Year: 2002

Exhaled air dispersion and use of oronasal masks with continuous positive airway pressure during COVID-19
Source: Eur Respir Rev, 29 (157) 200144; 10.1183/16000617.0144-2020
Year: 2020



Possible use of exhaled breath condensate (EBC) for continuous monitoring of lung inflammation in artificial ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

A new approach for exhaled breath condensate analysis by calculating the release of mediators per minute, standardised for the total water vapour in exhaled air
Source: Annual Congress 2010 - Exercise in healthy and non-respiratory diseases
Year: 2010

Reproducibility data of breath analysis through a gas sensors array and comparison to spirometry in COPD patients
Source: Annual Congress 2011 - Monitoring with lung function tests in airway diseases
Year: 2011

The concentration of total protein in exhaled breath condensate (EBC) depends on various variables of ventilation
Source: Eur Respir J 2006; 28: Suppl. 50, 283s
Year: 2006

Comparison of measures of ventilation heterogeneity derived from multiple breath inert gas washout
Source: Annual Congress 2012 - Pathophysiological mechanisms in disease: new insights
Year: 2012

Mitigating increased variability of multiple breath washout indices due to tidal breathing
Source: Eur Respir J, 57 (2) 2002765; 10.1183/13993003.02765-2020
Year: 2021



Variability of the exhaled breath condensate pH with different methods of analysis
Source: Eur Respir J 2005; 26: Suppl. 49, 260s
Year: 2005

Do deviations in tidal breathing impact multiple breath washout measurements?
Source: International Congress 2018 – Cystic fibrosis: diagnosis and monitoring
Year: 2018



Spirometric parameters during expired breath condensate collection in patients with COPD
Source: Eur Respir J 2001; 18: Suppl. 33, 92s
Year: 2001

Reproducibility of exhaled breath condensate pH measurements with a hand-held device in wheezing children
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

Comparison of ventilation inhomogeneity assessed by VC and tidal breath inert gas washout in children with mild-to-severe CF lung disease
Source: Eur Respir J 2001; 18: Suppl. 33, 347s
Year: 2001

Influence of breathing pattern on exhaled breath condensate collection
Source: Eur Respir J 2002; 20: Suppl. 38, 174s
Year: 2002

Exhaled breath condensate pH standardised for CO2 partial pressure
Source: Eur Respir J 2007; 29: 496-501
Year: 2007



Changes in exhaled breath condensate in asthma and COPD: A full analysis of mass-spectra
Source: Annual Congress 2010 - Exhaled biomarkers: smells like disease
Year: 2010