O2 as sweep gas shows slightly more effective decarboxylation compared to air in an in-vitro ECCO2R test setup

L. Schwaerzel (Homburg, Germany), A. Jungmann (Homburg, Germany), N. Schmoll (Bad Kreuznach, Germany), J. Schenk (Homburg, Germany), T. Dinh (Homburg, Germany), R. Bals (Homburg, Germany), P. Lepper (Homburg, Germany), A. Omlor (Homburg, Germany)

Source: International Congress 2019 – ECMO, ECCO2R and other rescue therapies in acute respiratory failure
Session: ECMO, ECCO2R and other rescue therapies in acute respiratory failure
Session type: Poster Discussion
Number: 2187
Disease area: Paediatric lung diseases, Respiratory critical care

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
L. Schwaerzel (Homburg, Germany), A. Jungmann (Homburg, Germany), N. Schmoll (Bad Kreuznach, Germany), J. Schenk (Homburg, Germany), T. Dinh (Homburg, Germany), R. Bals (Homburg, Germany), P. Lepper (Homburg, Germany), A. Omlor (Homburg, Germany). O2 as sweep gas shows slightly more effective decarboxylation compared to air in an in-vitro ECCO2R test setup. 2187

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Recirculation loop only slightly decrease decarboxylation performance in an in-vitro ECCO2R test setup and can be compensated by local acidification
Source: International Congress 2019 – ECMO, ECCO2R and other rescue therapies in acute respiratory failure
Year: 2019


Effect of air and heliox as carrier gas on CO2 diffusion in a model of high frequency oscillation comparing two oscillators
Source: Eur Respir J 2001; 18: Suppl. 33, 456s
Year: 2001

Is the initial stable value of transcutaneous oxygen/carbon dioxide monitoring equivalent to the blood gas values in oxygen assessments?
Source: Eur Respir J 2007; 30: Suppl. 51, 181s
Year: 2007

Inspired oxygen fraction during non-invasive ventilation: the influence of flow rates, masks, exhalation ports and ventilatory settings
Source: International Congress 2018 – Non-invasive ventilation in chronic respiratory failure
Year: 2018


Modifications to a photoacoustic gas analyser increases accuracy of functional residual capacity measurements by multiple breath washout of SF6 in an infant lung model
Source: Annual Congress 2008 - Clinical applications of ventilatory function tests in paediatric pulmonology
Year: 2008


A model based parametric analysis of the CO2 elimination versus expired volume curve for the computerized analysis of ventilatory efficiency
Source: Eur Respir J 2002; 20: Suppl. 38, 106s
Year: 2002

Measurement of functional residual capacity in mechanically ventilated monkeys using the molar mass signal of an ultrasonic flow meter compared to the nitrogen washout method
Source: Eur Respir J 2001; 18: Suppl. 33, 455s
Year: 2001

Performance in tracking heart rate of a combined pulse oximeter and carbon dioxide sensor incorporating novel signal processing
Source: Eur Respir J 2005; 26: Suppl. 49, 116s
Year: 2005

Substituting methane to helium in measuring the single breath CO transfer factor
Source: Eur Respir J 2002; 20: Suppl. 38, 381s
Year: 2002

Measurement of functional residual capacity (FRC) determined by gas dilution in infants using an ultrasonic flowmeter and a sulphur-hexafluoride (SF6) washin/washout technique
Source: Eur Respir J 2001; 18: Suppl. 33, 117s
Year: 2001

Comparison of current high flow oxygen humidification systems with a novel humidifier (Pari HydrateÔ)
Source: Annual Congress 2007 - Mechanical ventilation and airways
Year: 2007


Comparison of methane versus helium as tracer gas in single breath diffusing capacity for carbon monoxide
Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing
Year: 2008

Performance of a novel humidification device for high flow oxygen therapy
Source: Eur Respir J 2006; 28: Suppl. 50, 189s
Year: 2006

Accuracy of a novel transcutaneous combined carbon dioxide and oxygen saturation sensor in ergometry
Source: Annual Congress 2007 - Exercise: measurements, techniques and paradigms
Year: 2007


Use of a heated SpO2-PCO2 single sensor: comparison of results versus arterial blood gas measurements
Source: Eur Respir J 2004; 24: Suppl. 48, 185s
Year: 2004

A comparison of oxygen tubing lengths and flow output with home oxygen equipment. How much tubing is too much
Source: Eur Respir J 2004; 24: Suppl. 48, 517s
Year: 2004

Sidestream ultrasonic flow sensor equipment for nitrogen washout technique
Source: Annual Congress 2010 - Lung function from infancy to adulthood
Year: 2010

Comparison of helium and sf6 multiple breath gas washout techniques in spontaneously breathing infants
Source: Eur Respir J 2003; 22: Suppl. 45, 383s
Year: 2003

Comparison of oxygen supplementation from portable oxygen concentrator and liquid oxygen during walk test in COPD patients on long term oxygen therapy
Source: Annual Congress 2007 - Pulmonary rehabilitation beyond training
Year: 2007


Comparison of measures of ventilation heterogeneity derived from multiple breath inert gas washout
Source: Annual Congress 2012 - Pathophysiological mechanisms in disease: new insights
Year: 2012