Highly efficient peripheral lung targeting with coarse aerosols using brief very low inspiratory flow

A. R. Clark, C. B. Chambers, S. Paboojian, C. Schuler, D. Muir, M. T. Newhouse (San Carlos, United States Of America; Hamilton, Canada)

Source: Annual Congress 2003 - Issues surrounding drug delivery
Session: Issues surrounding drug delivery
Session type: Thematic Poster Session
Number: 2981
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. R. Clark, C. B. Chambers, S. Paboojian, C. Schuler, D. Muir, M. T. Newhouse (San Carlos, United States Of America; Hamilton, Canada). Highly efficient peripheral lung targeting with coarse aerosols using brief very low inspiratory flow. Eur Respir J 2003; 22: Suppl. 45, 2981

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest
Source: Eur Respir J 2001; 17: 1120-1127
Year: 2001



The use of functional respiratory imaging to investigate the impact of an oscillating positive expiratory pressure device on lung dynamics and drug deposition
Source: International Congress 2018 – New insights in testing lung and respiratory muscle functions
Year: 2018




Influence of expiratory flow limitation in COPD on regional lung deposition
Source: Annual Congress 2004 - Acute exacerbations and drug therapy in COPD
Year: 2004


Continuous assessment of inspiratory resistive work as a reliable indicator of progressive lung oedema in isolated rat lungs
Source: Eur Respir J 2006; 28: Suppl. 50, 345s
Year: 2006

Identifying patient suitability for lung volume reduction – estimation of gas trapping from spirometry.
Source: Virtual Congress 2020 – Prognosis and integrated management of COPD
Year: 2020


Exchange of highly soluble gases in the lung airways with the bronchial circulation
Source: Eur Respir J 2004; 24: Suppl. 48, 327s
Year: 2004

Coupling of noninvasive mechanical ventilation and nebulization during asthma exacerbations: higher amount of aerosol deposition into the airways or effective mechanical brochodilation due to positive pressure?
Source: Annual Congress 2009 - Treatment modalities in chest physiotherapy
Year: 2009

Increased frequency dependence of specific airway resistance in patients with laryngeal hemiplegia
Source: Eur Respir J 2001; 18: 1003-1008
Year: 2001



Effect of ambulatory continuous positive airway pressure on neural respiratory drive and functional capacity in excessive dynamic airway collapse
Source: International Congress 2018 – Exercise is medicine: testing and treating patients with some effort
Year: 2018



Continuous positive airway pressure, non-invasive ventilation and high flow nasal oxygen: lessons for success
Source: Virtual Congress 2021 – Continuous positive airway pressure, non-invasive ventilation and mechanical ventilation
Year: 2021


High flow nasal cannula: influence of gas type and flow rate on positive airway pressure and CO2 clearance in adult nasal airway replicas
Source: International Congress 2018 – New tools for managing respiratory failure
Year: 2018


Aerosolized perfluorocarbon improves gas exchange and reduces lung injury more effectively than high frequency oscillatory ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 37s
Year: 2002

Long term high flow heated oxygen treatment in COPD – lung function and physical ability
Source: International Congress 2017 – Innovation in pulmonary rehabilitation and chronic care
Year: 2017




Noninvasive ventilation in stable hypercapnic COPD: sequential effects on arterial blood gases, respiratory lung function and exercise capacity
Source: Eur Respir J 2002; 20: Suppl. 38, 234s
Year: 2002

Effects of varying the initial flow rate and expiratory trigger on breathing pattern and inspiratory effort during pressure support ventilation
Source: Eur Respir J 2003; 22: Suppl. 45, 442s
Year: 2003

Assessment of a new airway clearance technology on maximal slow expiratory volume.
Source: International Congress 2019 – Role of the physiotherapist for patients with lung disease
Year: 2019

Consistency of aerosol characteristics at low flow rates for a novel mesh nebulizer
Source: International Congress 2018 – Pulmonary drug delivery: inhaler use, devices and technologies
Year: 2018


Measurement of inspiratory flow through 3 different dry powder inhalation devices using In-check in asthmatic children
Source: Eur Respir J 2001; 18: Suppl. 33, 493s
Year: 2001

Ozone exposure decreases the effect of a deep inhalation on forced expiratory flow in normal subjects
Source: Eur Respir J 2001; 18: Suppl. 33, 32s
Year: 2001

Measurement of lung volume and ventilation distribution with an ultrasonic flow meter in healthy infants
Source: Eur Respir J 2002; 20: 912-918
Year: 2002