Impact of leaks in sulfur hexafluoride and nitrogen multiple-breath washout systems Source: ERJ Open Res, 4 (4) 00119-2018; 10.1183/23120541.00119-2018 Year: 2018
Comparison of helium dilution and sulphur hexafluoride multiple breath measurements of functional residual capacity in neonates Source: Eur Respir J 2007; 30: Suppl. 51, 396s Year: 2007
Outcome of multiple breath washout (MBW) in healthy children using two different gases (N2 and SF6) with the same equipment Source: International Congress 2017 – What is new in respiratory and sleep physiology? Year: 2017
The validity of shortened multiple-breath washout testing using sulfur hexafluoride in the assessment of patients with COPD Source: ERJ Open Res, 7 (3) 00379-2020; 10.1183/23120541.00379-2020 Year: 2021
Effect of intermittent inspiratory leaks on measurement of lung clearance index using nitrogen and sulfur hexafluoride Source: ERJ Open Res, 4 (4) 00132-2018; 10.1183/23120541.00132-2018 Year: 2018
Effect of intermittent inspiratory leaks on measurement of lung clearance index using nitrogen and sulfur hexafluoride Source: ERJ Open Res, 4 (4) 00140-2018; 10.1183/23120541.00140-2018 Year: 2018
Multiple breath washout (MBW) using sulfur hexafluoride – Proof of concept in COPD Source: International Congress 2016 – Exploring mechanisms in health and disease Year: 2016
Defining the appropriate waiting time between multiple-breath nitrogen washout measurements Source: Eur Respir J 2015; 45: 1489-1491 Year: 2015
Reference values for lung clearance index (LCI) derived from sulphur hexafluoride multiple breath washout testing. Source: Virtual Congress 2020 – Lung function tests and exhaled biomarkers Year: 2020
Multiple-breath inert gas washout (MBW) in healthy children using an ultrasonic flowmeter Source: Eur Respir J 2004; 24: Suppl. 48, 376s Year: 2004
Feasibility and variability of the double-tracer gas single-breath washout in a paediatric field study. Source: International Congress 2019 – Evaluation of breathing in children when they are asleep, healthy or ill Year: 2019
Comparison of methane versus helium as tracer gas in single breath diffusing capacity for carbon monoxide Source: Annual Congress 2008 - Beyond spirometry: the skills behind lung function testing Year: 2008
In vitro and in vivo functional residual capacity comparisons between multiple-breath nitrogen washout devicesSource: ERJ Open Res, 3 (4) 00011-2017; 10.1183/23120541.00011-2017 Year: 2017
Controlled versus free breathing for multiple-breath nitrogen washout in asthma Source: ERJ Open Res, 7 (4) 00487-2021; 10.1183/23120541.00487-2021 Year: 2021
Comparison of measures of ventilation heterogeneity derived from multiple breath inert gas washout Source: Annual Congress 2012 - Pathophysiological mechanisms in disease: new insights Year: 2012
Modifications to a photoacoustic gas analyser increases accuracy of functional residual capacity measurements by multiple breath washout of SF6 in an infant lung model Source: Annual Congress 2008 - Clinical applications of ventilatory function tests in paediatric pulmonology Year: 2008
Leaks during multiple-breath washout: characterisation and influence on outcomes Source: ERJ Open Res, 4 (1) 00012-2017; 10.1183/23120541.00012-2017 Year: 2018
Multiple-breath washout Source: Eur Respir Mon; 2010: 47: 87–104 Year: 2010
Carbon dioxide (CO2) insufflation: a potential source of error in TLCO measurement Source: International Congress 2019 – Quality, performance and interpretation of lung function testing Year: 2019
A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease Source: Eur Respir J 2013; 41: 339-345 Year: 2013