Exhaled nitrite as a marker of lung injury induced by volume controlled (VC) mechanical ventilation (MV) during general anesthesia

A. E. Skrahin, A. S. Smirnov, A. D. Tahanovich, D. H. Petchinski, A. M. Skrahina, A. I. Alesitch, T. A. Skrahina (Minsk, Belarus)

Source: Annual Congress 2004 - Monitoring acute respiratory failure
Session: Monitoring acute respiratory failure
Session type: Poster Discussion
Number: 4115
Disease area: Respiratory critical care

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. E. Skrahin, A. S. Smirnov, A. D. Tahanovich, D. H. Petchinski, A. M. Skrahina, A. I. Alesitch, T. A. Skrahina (Minsk, Belarus). Exhaled nitrite as a marker of lung injury induced by volume controlled (VC) mechanical ventilation (MV) during general anesthesia. Eur Respir J 2004; 24: Suppl. 48, 4115

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Exhaled eicosanoids in patients subjected to mechanical ventilation (MV) during general anesthesia
Source: Annual Congress 2007 - Airway regulation, provocation and monitoring I
Year: 2007


The level of nitrate in exhaled breath condensate (EBC) after mechanical ventilation (MV) does not depend on MV parameters
Source: Eur Respir J 2006; 28: Suppl. 50, 399s
Year: 2006

General anesthesia with mechanical ventilation decreases exhaled breath condensate volume
Source: Eur Respir J 2004; 24: Suppl. 48, 675s
Year: 2004

The influence of mechanical ventilation during general anesthesia on the state of metabolism markers in exhaled breath condensate
Source: Eur Respir J 2005; 26: Suppl. 49, 556s
Year: 2005

Exhaled breath condensate nitrite as a marker for lung injury involving alveolar (over) distension
Source: Eur Respir J 2002; 20: Suppl. 38, 228s
Year: 2002

Increased pressure amplitude in mechanical ventilation leads to an increase in the breath condensate volume (BCV) to ventilation (Ve) ratio
Source: Eur Respir J 2001; 18: Suppl. 33, 481s
Year: 2001

Effects of low lung volume ventilation on respiratory mechanics and nitric oxide exhalation in normal rabbits
Source: Eur Respir J 2005; 26: Suppl. 49, 558s
Year: 2005

The use of a new intra-pulmonary percussive ventilation (IPPV) device to aid lung volume recruitment (LVR) and secretion clearance in a patient with C1 spinal cord injury (SCI)
Source: International Congress 2016 – Novel avenues in the treatment of COPD II
Year: 2016


Possible use of exhaled breath condensate (EBC) for continuous monitoring of lung inflammation in artificial ventilation
Source: Eur Respir J 2002; 20: Suppl. 38, 85s
Year: 2002

Contribution of lung ventilation and perfusion distributions to the phase III slope of exhaled CO2 during acute bronchoconstriction studied by synchrotron imaging in rabbit
Source: Annual Congress 2013 –Clinical physiology and functional imaging in health and disease
Year: 2013

Protective ventilation strategy to reduce injury during one-lung ventilation (OLV): functional outcomes using an impulse oscillation system (IOS)
Source: Annual Congress 2009 - New data on respiratory function - from experimental approaches to man
Year: 2009


Optimisation of tidal volume (Vt) for minimising tidal lung overdistension during mechanical ventilation in ALI/ARDS: A modelling approach
Source: Annual Congress 2013 –Mechanical ventilation and weaning
Year: 2013

Analysis of CO2 rebreathing (CO2R) in hypercarbic patients (HP) while using different expiratory devices in noninvasive ventilation (NIV)
Source: Eur Respir J 2006; 28: Suppl. 50, 183s
Year: 2006

Lung perfusion and ventilation modifications induced by nasal non-invasive positive pressure ventilation (nNPPV) in patients with CRF due to severe COPD
Source: Eur Respir J 2002; 20: Suppl. 38, 625s
Year: 2002

Application of one-lung high frequency jet ventilation (OHFJV) in lung surgery
Source: Annual Congress 2012 - Special problems in thoracic surgery
Year: 2012


The concentration of total protein in exhaled breath condensate (EBC) depends on various variables of ventilation
Source: Eur Respir J 2006; 28: Suppl. 50, 283s
Year: 2006

Monitoring exhaled oxygen concentration during mechanical ventilation: a novel approach for bedside estimation of ventilation heterogeneities
Source: International Congress 2017 – Evaluating lung function, dyspnoea and related respiratory diseases
Year: 2017

Role of continuous tracheal gas insufflation (c-TGI) with protective lung ventilation in respiratory acidosis
Source: Annual Congress 2008 - Acute lung injury and weaning
Year: 2008


Changes in ventilation and respiratory impedance after sampling of exhaled breath condensate (EBC) in pigs
Source: Eur Respir J 2002; 20: Suppl. 38, 175s
Year: 2002

Relationship between basal and nitroglycerin (GTN)-induced exhaled nitric oxide (eNO) and oxygenation parameters in ventilated patients undergoing cardiopulmonary bypass (CPB)
Source: Eur Respir J 2004; 24: Suppl. 48, 264s
Year: 2004