Impulse oscillometry (IO) parameters after pneumonectomy in patients with pulmonary tuberculosis (PT)

L. Kiryukhina (St Petersburg, Russian Federation)

Source: International Congress 2017 – Lung function testing
Session: Lung function testing
Session type: Thematic Poster
Number: 2213

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
L. Kiryukhina (St Petersburg, Russian Federation). Impulse oscillometry (IO) parameters after pneumonectomy in patients with pulmonary tuberculosis (PT). 2213

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Total respiratory impedance by impulse oscillometry (IO) in patients with pulmonary tuberculosis (PT)
Source: International Congress 2016 – Respiratory muscles and airways function: from physiology to clinical implications
Year: 2016


Relationship between the Matrix Metalloproteinases (MMPs) levels and lung mechanic parameters established by impulse oscillometry (IOS) in patients with pulmonary tuberculosis (TB)
Source: Virtual Congress 2020 – Tuberculosis and comorbidities
Year: 2020


Impulse oscillometry (IOS) in emphysema: relationship to conventional lung function indices
Source: Eur Respir J 2003; 22: Suppl. 45, 100s
Year: 2003

Comparison of sputum induction (SI) with fiberoptic bronchoscopy (BFC) in the diagnosis of pulmonary tuberculosis (PTB)
Source: Eur Respir J 2001; 18: Suppl. 33, 361s
Year: 2001

The use test valsalva manoevre (VM) in diagnosis pulmonary hypertension (PH) for early rehabilitation of patients with lung sarcoidosis (LS)
Source: Eur Respir J 2006; 28: Suppl. 50, 72s
Year: 2006

Noninvasive ventilation (NIV) after lung resection (LR) to prevent respiratory complications (RCs) in COPD patients (pts) (POPVNI trial)
Source: Annual Congress 2011 - Noninvasive ventilation in the acute setting: education, organisation, H1N1, paediatrics, weaning, diagnostic procedures and special considerations
Year: 2011

Reproducibility of resistance (R) and reactance (X) responses to bronchodilator (BD) measured by the impulse oscillation system (IOS) in patients with stable COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 63s
Year: 2005

Impulse oscillometry compared to standard lung function testing in patients with idiopathic pulmonary fibrosis
Source: International Congress 2018 – CTD-ILD and hypersensitivity pneumonitis:  mechanistic insights and prognostic markers
Year: 2018


Reproducibility of resistance (R) and reactance (X) measured with the impulse oscillation system (IOS) in patients with COPD
Source: Eur Respir J 2005; 26: Suppl. 49, 65s
Year: 2005

Adult Cystic Fibrosis (CF) patients prefer to perform impulse oscillometry (IOS) in comparison to spirometry.
Source: International Congress 2019 – Physiology of cystic fibrosis
Year: 2019


Is impulse oscillometry (IOS) better than spirometry for monitoring treatment outcomes in adult cystic fibrosis (CF) pulmonary exacerbations? A pilot study
Source: International Congress 2019 – Physiology of cystic fibrosis
Year: 2019


Dead space/tidal volume ratio (VD/VT) and pulmonary function (PF) in children with obstructive acute respiratory failure (OARF) on invasive mechanical pulmonary ventilation (IMPV)
Source: Eur Respir J 2004; 24: Suppl. 48, 676s
Year: 2004

Forced oscillation technique (FOT) in the evaluation of COPD patients enrolled in Pulmonary Rehabilitation (PR)
Source: International Congress 2019 – Hot topics in pulmonary rehabilitation
Year: 2019

Comparison of two methods of detection of expiratory flow limitation (EFL) in chronic obstructive pulmonary disease (COPD): Sinusoids vs. Impulse oscillometry
Source: Annual Congress 2010 - Spotlight on lung function
Year: 2010

Ventilation disorders by impulse oscillometry in pulmonary tuberculosis patients in early post-operative period
Source: Virtual Congress 2021 – Thoracic surgery, lung cancer and complications of COVID-19
Year: 2021


The use of impulse oscillometry (IOS) in the differentiation of bronchiectasis and emphysema in patients with alpha1 antitrypsin deficiency (α1-ATD)
Source: Annual Congress 2004 - Airway resistance: application and technique
Year: 2004


Pulmonary resistance measured by impulse oscillometry system (IOS) seems to be related to self-reported COPD and respiratory symptoms
Source: Annual Congress 2011 - Respiratory epidemiology: methods, definitions and phenotypes
Year: 2011

Incidence of chest infections (CI) in patients with neuromuscular disease (NMD) in the first 2 weeks after commencement of Non-invasive Ventilation (NIV) or Mechanical In-Exsufflation (MI-E)
Source: Respiratory Failure and Mechanical Ventilation Conference 2020
Year: 2020



Detection of bronchial asthma using impulse oscillation system (IOS) in patients with normal spirometry
Source: Annual Congress 2012 - Mechanics, muscles and movement: aspects of airway mechanics, repiratory muscle assessment and field exercise tests
Year: 2012

Impulse oscillometry parameters in patients with severe COPD after lung volume reduction surgery
Source: Eur Respir J 2004; 24: Suppl. 48, 121s
Year: 2004