Particle size variation of nebulized albuterol occurs while traveling through neonatal mechanical ventilation circuits.

A. Berlinski (Little Rock, United States of America)

Source: International Congress 2017 – NICU/ PICU: evaluating short- and long-term ventilatory management
Session: NICU/ PICU: evaluating short- and long-term ventilatory management
Session type: Poster Discussion
Number: 2065
Disease area: Respiratory critical care

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
A. Berlinski (Little Rock, United States of America). Particle size variation of nebulized albuterol occurs while traveling through neonatal mechanical ventilation circuits.. 2065

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
In vitro comparison of output and particle size distribution of budesonide from metered-dose inhaler with three spacer devices during pediatric tidal breathing
Source: Eur Respir J 2005; 26: Suppl. 49, 161s
Year: 2005

Effect of different connections on aerosol delivery during non-invasive mechanical ventilation.
Source: Virtual Congress 2020 – Non-invasive ventilation and nasal high flow: technical aspects and predictive scores
Year: 2020


Influence of nebulizer type, position and bias flow on aerosol drug delivery to a pediatric model of mechanical ventilation
Source: Annual Congress 2008 - Respiratory disorders in paediatric intensive care unit
Year: 2008


Jet nebulization associated to noninvasive mechanical ventilation (NMV): pulmonary deposition pattern of inhaled radioaerossol
Source: Eur Respir J 2004; 24: Suppl. 48, 407s
Year: 2004

Effect of tidal volume and nebuliser position on aerosol delivery during neonate ventilation
Source: Respiratory Failure and Mechanical Ventilation Conference 2020
Year: 2020



Coupling of noninvasive mechanical ventilation and nebulization during asthma exacerbations: higher amount of aerosol deposition into the airways or effective mechanical brochodilation due to positive pressure?
Source: Annual Congress 2009 - Treatment modalities in chest physiotherapy
Year: 2009

Comparison of response to aerosol drug delivery with mesh and jet nebulizers during non-invasive ventilation (NIV) in acute exacerbation of COPD.
Source: International Congress 2017 – Clinical and physiological challenges in noninvasive ventilation
Year: 2017


Comparative efficiency of nebulizer locations in a pediatric mechanical ventilator circuit
Source: Eur Respir J 2004; 24: Suppl. 48, 620s
Year: 2004

Air stacking, cough machine – in/exsufflator, high frequency oscillation and intrapulmonary percussive ventilation
Source: Annual Congress 2005 - Management of airway hypersecretions
Year: 2005

In vitro evaluation of a new spacer for pMDI and nebulizers in mechanical ventilation
Source: Annual Congress 2012 - Multidisciplinary critical care
Year: 2012


Effects from nebulisation associated to noninvasive mechanical ventilation in acute asthma
Source: Annual Congress 2007 - Critical care and airways clearance
Year: 2007


In vitro delivery of budesonide from 10 jet nebulisers using a child breathing pattern
Source: Annual Congress 2007 - New treatments for asthma and COPD - experimental evidence
Year: 2007


The change of respiratory and circulation parameter during the weaning of sequential invasive-noninvasive mechanical ventilation
Source: Eur Respir J 2001; 18: Suppl. 33, 184s
Year: 2001

In vitro evaluation of aerosolized delivery of various medications during mechanical ventilation
Source: International Congress 2017 – Pulmonary drug and devices delivery
Year: 2017


Influence of tidal volume increase on respiratory mechanics during mechanical ventilation in ARDS
Source: Annual Congress 2004 - New tools and new concepts in respiratory monitoring
Year: 2004


Evaluation of aerosol delivery in a simulated spontaneously breathing tracheostomy mask patient
Source: Virtual Congress 2020 – Novel findings in intensive care unit medicine: part 2
Year: 2020


Assessment of passive humidifier performance following on-ventilator aerosol therapy
Source: International Congress 2016 – Pulmonary drug delivery
Year: 2016


Comparisons of predictive performance of breathing pattern variabilities measured during T-piece, automatic tube compensation and pressure support ventilation for weaning ICU patients from mechanical ventilation
Source: Annual Congress 2011 - Mechanical ventilation and lung injury: new advances
Year: 2011

Bronchodilators delivery during mechanical ventilation
Source: Annual Congress 2007 - Bronchodilator delivery during mechanical ventilation
Year: 2007