Poor agreement between haemoglobin oxygen saturation measured by pulse oximetry and arterialized earlobe blood gas in ambulatory paediatric sickle cell patients

Sean Zheng (London, United Kingdom), Sean Zheng, Gary Ruiz, Fiona Chan, Subarna Chakravorty, Cara Bossley, David Rees, Atul Gupta

Source: International Congress 2016 – What's new in paediatric respiratory physiology?
Session: What's new in paediatric respiratory physiology?
Session type: Thematic Poster
Number: 1217
Disease area: Paediatric lung diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
Sean Zheng (London, United Kingdom), Sean Zheng, Gary Ruiz, Fiona Chan, Subarna Chakravorty, Cara Bossley, David Rees, Atul Gupta. Poor agreement between haemoglobin oxygen saturation measured by pulse oximetry and arterialized earlobe blood gas in ambulatory paediatric sickle cell patients. Eur Respir J 2016; 48: Suppl. 60, 1217

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Comparison of fingertip and earlobe pulse oximetry with arterial blood gas results
Source: International Congress 2016 – Long-term oxygen therapy, noninvasive ventilation, and other clinical variables in chronic lung diseases
Year: 2016


Diagnostic accuracy of venous blood gases compared to arterial blood gases
Source: Annual Congress 2013 –Various issues in clinical respiratory physiology
Year: 2013


A survey of arterial blood gas use and analysis in respiratory inpatients
Source: Annual Congress 2013 –New treatments and old dilemmas in the clinical management of lung diseases
Year: 2013


The correlation of arterial oxygen saturation measured by pulse oxymeter and by arterial blood gas analyzer in patients with chronic respiratory failure
Source: Eur Respir J 2005; 26: Suppl. 49, 526s
Year: 2005

Pilot study to assess physician compliance in non-invasive ventilation titration based on venous blood gasses versus arterial blood gasses in acute respiratory failure patients
Source: Virtual Congress 2020 – Nasal high flow and non-invasive ventilation in acute and chronic care
Year: 2020




Comparison of pulse oximetry and arterial bood gas analysis in cases with dyspnea
Source: Eur Respir J 2007; 30: Suppl. 51, 328s
Year: 2007

The comparison of arterial oxygen saturation measured by pulse oxymeter and by arterial blood gas analyzer in hypoxemic and nonhypoxemic pulmonary diseases
Source: Eur Respir J 2003; 22: Suppl. 45, 416s
Year: 2003

Comparative analysis of the arterial oxygen saturation (SaO2) and pulse oximetry measurements (SpO2) in patients with pulmonary tuberculosis
Source: Virtual Congress 2020 – Lung function diagnostics
Year: 2020


Converting venous acid-base and oxygen status to arterial in patients with lung disease
Source: Eur Respir J 2009; 33: 1141-1147
Year: 2009



Misunderstanding the arterial blood oxygen saturation
Source: Case Report 2013
Year: 2013

Exercise pulse oximetry is a poor surrogate for diffusion limitation in paediatric oncology patients
Source: International Congress 2014 – Respiratory function at rest and during exercise
Year: 2014


Comparison of anamnesis, blood gas analysis and home overnight oximetry in the follow-up of patients using NIV at home
Source: Annual Congress 2009 - Noninvasive ventilation: new and old aspects
Year: 2009


Hypoxia altitude simulation test (HAST): Arterial blood gases or pulse oximetry?
Source: Annual Congress 2011 - Challenges in chronic disease management: helping individuals with chronic lung disease remain stable
Year: 2011

Vital capacity, arterial blood gases and disability in neuromuscular patients admitted for the first time in a respiratory ambulatory
Source: Eur Respir J 2004; 24: Suppl. 48, 517s
Year: 2004

Surveying the practice of arterialised earlobe capillary blood gas sampling amongst respiratory specialists practitioners
Source: Annual Congress 2013 –Airway calibre, airway challenge and assessment of oxygenation
Year: 2013


Accuracy and reliability of pulse oximetry at different arterial carbon dioxide pressure levels
Source: Eur Respir J 2008; 32: 1053-1059
Year: 2008



Home respiratory monitoring in infants born preterm using pulse oximeter plethysmogram analysis
Source: International Congress 2015 – Paediatric respiratory physiology
Year: 2015

Monitoring carbon dioxide tension and arterial oxygen saturation using TOSCA monitoring in general respiratory ward
Source: Eur Respir J 2006; 28: Suppl. 50, 394s
Year: 2006

Functional and arterial blood gases changes after a rehabilitation programme in patients with bronchiectasis
Source: Annual Congress 2009 - Pulmonary rehabilitation: extending the scope and benefit of rehabilitation for patients with chronic respiratory disease
Year: 2009


Reducing hospital admission in COPD exacerbation by urgent oxygen provision and home monitoring of capillary blood gases
Source: Annual Congress 2012 - COPD exacerbation
Year: 2012