Oscillating postive expiratory pressure (OPEP) increases the concentration of protein in exhaled breath condensate (EBC)

S. S. Wagers, S. E. Lang, J. A. Thompson-Figueroa, G. S. Davis (Burlington, United States Of America)

Source: Annual Congress 2005 - Physiological studies in healthy humans
Session: Physiological studies in healthy humans
Session type: Thematic Poster Session
Number: 3666
Disease area: Airway diseases

Congress or journal article abstract

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
S. S. Wagers, S. E. Lang, J. A. Thompson-Figueroa, G. S. Davis (Burlington, United States Of America). Oscillating postive expiratory pressure (OPEP) increases the concentration of protein in exhaled breath condensate (EBC). Eur Respir J 2005; 26: Suppl. 49, 3666

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
The concentration of total protein in exhaled breath condensate (EBC) depends on various variables of ventilation
Source: Eur Respir J 2006; 28: Suppl. 50, 283s
Year: 2006

Circadian variation in exhaled breath condensate (EBC) pH, volume and total protein concentration
Source: Eur Respir J 2005; 26: Suppl. 49, 373s
Year: 2005

Protein pattern of exhaled breath condensate (EBC) and saliva
Source: Eur Respir J 2001; 18: Suppl. 33, 461s
Year: 2001

Within the exhaled breath condensate (EBC), nitrite and LTB4 are correlated to each other when calculated per 100 litres exhaled breath
Source: Eur Respir J 2006; 28: Suppl. 50, 789s
Year: 2006

Increased lactate concentrations in exhaled breath condensate (EBC) in COPD
Source: Eur Respir J 2007; 30: Suppl. 51, 584s
Year: 2007

Changes in ventilation and respiratory impedance after sampling of exhaled breath condensate (EBC) in pigs
Source: Eur Respir J 2002; 20: Suppl. 38, 175s
Year: 2002

Ammonia and urea in the exhaled breath condensate (EBC) and in corresponding blood samples
Source: Eur Respir J 2002; 20: Suppl. 38, 482s
Year: 2002

The level of nitrate in exhaled breath condensate (EBC) after mechanical ventilation (MV) does not depend on MV parameters
Source: Eur Respir J 2006; 28: Suppl. 50, 399s
Year: 2006

Exhaled breath condensate pH and peak flow variability in asthma
Source: Annual Congress 2008 - Inflammatory biomarkers
Year: 2008


Determinants of variability in exhaled breath condensate (EBC) in children
Source: Annual Congress 2008 - Inflammatory biomarkers
Year: 2008

Exhaled breath condensate pH standardised for CO2 partial pressure
Source: Eur Respir J 2007; 29: 496-501
Year: 2007



The coating of condenser systems influences the detection of 8-isoprostane in exhaled breath condensate (EBC)
Source: Eur Respir J 2004; 24: Suppl. 48, 468s
Year: 2004

Detection and variability of cytokine-levels in exhaled breath condensate (EBC) of patients with stable COPD
Source: Eur Respir J 2003; 22: Suppl. 45, 438s
Year: 2003

Nitrite/nitrate in exhaled breath condensate (EBC) of patients with COPD
Source: Eur Respir J 2006; 28: Suppl. 50, 671s
Year: 2006

Electrical conductivity, pH and ammonia in exhaled breath condensate (EBC) from patients with different airway disorders
Source: Eur Respir J 2006; 28: Suppl. 50, 790s
Year: 2006

The 3-nitrothyrozine and total nitrate/nitrite (TNN) levels in exhaled breath condensate (EBC) in patients with bronchial asthma (BA)
Source: Annual Congress 2009 - Airway inflammation and asthma control
Year: 2009

Short-term variation and influence of a nose clip on nitrite (NI) and nitrate (NA) levels in the exhaled breath condensate (EBC)
Source: Eur Respir J 2003; 22: Suppl. 45, 267s
Year: 2003

The effect of gas standardisation on exhaled breath condensate pH and PCO2
Source: Eur Respir J 2007; 30: 185-187
Year: 2007