A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: The DREAM European validation study

P. Defaye, I. De la Cruz, J. Marti-Almor, R. Villuendas, P. Bru, J. Senechal, R. Tamisier, J. L. Pepin (Grenoble, La Rochelle, Clamart, France; Sevilla, Barcelona, Badalona, Spain)

Source: International Congress 2014 – Sleep disordered breathing 1
Session: Sleep disordered breathing 1
Session type: Thematic Poster Session
Number: 2208
Disease area: Sleep and breathing disorders

Congress or journal article abstractE-poster

Rating: 0
You must login to grade this presentation.

Share or cite this content

Citations should be made in the following way:
P. Defaye, I. De la Cruz, J. Marti-Almor, R. Villuendas, P. Bru, J. Senechal, R. Tamisier, J. L. Pepin (Grenoble, La Rochelle, Clamart, France; Sevilla, Barcelona, Badalona, Spain). A pacemaker transthoracic impedance sensor with an advanced algorithm to identify severe sleep apnea: The DREAM European validation study. Eur Respir J 2014; 44: Suppl. 58, 2208

You must login to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.

Member's Comments

No comment yet.
You must Login to comment this presentation.


Related content which might interest you:
Evaluation of respiratory effort in sleep apnea patients using a new method for suprasternal pressure recording
Source: International Congress 2016 – Novel tools and approaches to diagnosing obstructive sleep apnoea
Year: 2016



Performance of utility instruments in evaluating response to CPAP in patients with obstructive sleep apnea
Source: International Congress 2014 – The technical and diagnostic agenda in OSA
Year: 2014

Validation of a suprasternal pressure transducer for sleep apnea classification in children
Source: International Congress 2016 – Clinical presentation, daytime symptoms, and screening of obstructive sleep apnoea
Year: 2016

Evaluation of automatic scoring algorithm for home sleep diagnosis
Source: Annual Congress 2013 –Sleep disordered breathing in special situations III
Year: 2013


Validation of SleepMinder as non-contact device for sleep-disordered breathing and periodic limb movement
Source: International Congress 2015 – Acute and chronic lung diseases: good clinical practice
Year: 2015


Effects of pathological respiratory pattern on heart rate turbulence in sleep apnea
Source: International Congress 2014 – The story continues: impact of OSA on cardiometabolic parameters
Year: 2014

Validation of a Cheyne-Stokes respiration (CSR) detection algorithm for a CPAP device
Source: International Congress 2014 – The technical and diagnostic agenda in OSA
Year: 2014

Evaluation of the apnea-hypopnea index determined by adaptive-servo ventilation devices in heart failure patients with sleep disordered breathing
Source: International Congress 2014 – The technical and diagnostic agenda in OSA
Year: 2014


Network-based assessment of sleep apnea syndrome treatment response
Source: International Congress 2014 – Sleep disordered breathing 1
Year: 2014


Electrical auricle stimulation device for obstructive and central sleep apnoea: A pilot study
Source: Annual Congress 2013 –Twist in the tale: treating sleep disordered breathing - new technologies, new techniques
Year: 2013


HRV analysis in obstructive sleep apnea syndrome by means of LF/HF ratio and fractal dimension
Source: International Congress 2014 – The story continues: impact of OSA on cardiometabolic parameters
Year: 2014

Evaluation of wireless telemonitoring of CPAP therapy in obstructive sleep apnea - TELEPAP study
Source: Annual Congress 2013 –Ask, see and do: old and new technology in sleep disordered breathing
Year: 2013


AER score: An efficient predictor for sleep apnea syndrome
Source: International Congress 2014 – Sleep disordered breathing 2
Year: 2014


Sleep breathing disorders, nocturnal atrial fibrillation and nCPAP treatment
Source: International Congress 2014 – Sleep disordered breathing 2
Year: 2014


LATE-BREAKING ABSTRACT: Adaptive servo-ventilation in Central Sleep Apnea. Ambulatory nocturnal pulse oximetry, a simplified method for monitoring outpatient?
Source: International Congress 2014 – Sleep disordered breathing 4
Year: 2014


LATE-BREAKING ABSTRACT: An automatic positive airway pressure algorithm designed for women: a bench study
Source: International Congress 2014 – The technical and diagnostic agenda in OSA
Year: 2014

Clinical characteristics and sleep discorded breathing in an elderly population referred for sleep study
Source: International Congress 2014 – Evaluating sleep disordered breathing in children and adults
Year: 2014


Long-term evaluation of positional therapy with the sleep position trainer (SPT) in the treatment of positional obstructive sleep apnea syndrome (POSA)
Source: International Congress 2014 – The technical and diagnostic agenda in OSA
Year: 2014


Impact of speed and age on an office based advanced driving simulator (MinUoLDS) between obstructive sleep apnoea syndrome (OSAS) patients and controls
Source: International Congress 2014 – Sleep disordered breathing 2
Year: 2014


Treatment of postural obstructive sleep apnoea by a new vibrating postural device. A preliminary study
Source: Annual Congress 2013 –Twist in the tale: treating sleep disordered breathing - new technologies, new techniques
Year: 2013