e-learning
resources
Munich 2014
Monday, 08.09.2014
Lung function testing: new findings and new approaches
Login
Search all ERS
e-learning
resources
Disease Areas
Airways Diseases
Interstitial Lung Diseases
Respiratory Critical Care
Respiratory Infections
Paediatric Respiratory Diseases
Pulmonary Vascular Diseases
Sleep and Breathing Disorders
Thoracic Oncology
Events
International Congress
Courses
Webinars
Conferences
Research Seminars
Journal Clubs
Publications
Breathe
Monograph
ERJ
ERJ Open Research
ERR
European Lung White Book
Handbook Series
Guidelines
All ERS guidelines
e-learning
CME Online
Case reports
Short Videos
SpirXpert
Procedure Videos
CME tests
Reference Database of Respiratory Sounds
Radiology Image Challenge
Brief tobacco interventions
EU Projects
VALUE-Dx
ERN-LUNG
ECRAID
UNITE4TB
Disease Areas
Events
Publications
Guidelines
e-learning
EU Projects
Login
Search
Improving MBW testing: Closed circuit washin with a novel bolus gas delivery reduces washin time and does not alter washout
A. Horsley, A. Bell (Manchester, United Kingdom)
Source:
International Congress 2014 – Lung function testing: new findings and new approaches
Session:
Lung function testing: new findings and new approaches
Session type:
Thematic Poster Session
Number:
2130
Rating:
You must
login
to grade this presentation.
Share or cite this content
Citations should be made in the following way:
A. Horsley, A. Bell (Manchester, United Kingdom). Improving MBW testing: Closed circuit washin with a novel bolus gas delivery reduces washin time and does not alter washout. Eur Respir J 2014; 44: Suppl. 58, 2130
You must
login
to share this Presentation/Article on Twitter, Facebook, LinkedIn or by email.
Member's Comments
No comment yet.
You must
Login
to comment this presentation.
Related content which might interest you:
Panel discussion: What’s NEW in the 2022 ERS/ATS PFT Interpretation Statement
From pulmonary gas exchange to the interpretation of arterial blood gases
The physiology of breathlessness
Related content which might interest you:
Slow and fast ventilated lung units in adult asthma assessed from N
2
multiple-breath washouts (MBW)
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014
Capnogram phase III slope and dead space parameters: Comparison of main- and sidestream capnography techniques
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014
In-vivo and in-vitro functional residual capacity comparisons between multiple breath nitrogen washout devices
Source: International Congress 2016 – Pathophysiological mechanisms at different levels: lung, airways, muscles and symptom perception
Year: 2016
Selecting a multiple-breath N2 washout device: The search continues
Source: International Congress 2015 – Lung function: waiting to exhale...
Year: 2015
Double-tracer gas single breath washout - Variability and reproducibility compared with classical nitrogen washout tests
Source: Annual Congress 2013 –New issues in lung function testing
Year: 2013
Closing volume detection by single breath gas nitrogen washout and forced oscillation technique
Source: Annual Congress 2013 –Lung function tests to monitor airway diseases
Year: 2013
Changes in regional distribution of gas and blood volumes within a single respiratory cycle: Effect of tidal volume, PEEP and respiratory pattern
Source: International Congress 2014 – Functional imaging
Year: 2014
Effects of using a mask vs mouthpiece on the multiple breath inert gas washout technique
Source: International Congress 2015 – Lung function: waiting to exhale...
Year: 2015
Impact of the use of a finite value of NO conductance on Hb in the interpretation of TLNO and TLCO transfer in homogenous groups of patients
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014
Relationships between spirometry, ventilation inhomogeneity and fast and slow ventilation lung units in COPD
Source: International Congress 2014 – Multidimensional analysis of respiratory problems
Year: 2014
Consensus statement for inert gas washout measurement using multiple- and single- breath tests
Source: Eur Respir J 2013; 41: 507-522
Year: 2013
Time course of thoracocentesis-induced alterations in lung function parameters
Source: International Congress 2014 – Lung function testing: new findings and new approaches
Year: 2014
Relevance of six-minute walk parameters in predicting pulmonary gas transfer
Source: International Congress 2014 – Multidimensional analysis of respiratory problems
Year: 2014
Influence of the cardiac cycle on the airflow patterns during inhalation in healthy subjects investigated with
3
He MRI
Source: International Congress 2014 – Functional imaging
Year: 2014
Simultaneous SF6 and N2 gas multiple breath washout (MBW); understanding the difference between test gases
Source: International Congress 2016 – The best is yet to come in terms of lung function
Year: 2016
Comparison of CT-based lobar ventilation models with
3
He MRI ventilation measurements in asthmatics
Source: International Congress 2014 – Functional imaging
Year: 2014
Comparison of functional residual capacity (FRC) from two multiple breath washout (MBW) systems and body plethysmography
Source: International Congress 2016 – What's new in paediatric respiratory physiology?
Year: 2016
A 3-week interval exercise-training program improves work efficiency following chemoradiotherapy
Source: International Congress 2014 – Alterations of exercise and lung function in different diseases
Year: 2014
Different indices of inert gas washout measurements define physiological phenotypes
Source: International Congress 2015 – Paediatric respiratory physiology
Year: 2015
Validation of a portable lung volume testing system
Source: International Congress 2014 – Respiratory function: quality and new technologies
Year: 2014
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking "Accept", you consent to the use of the cookies.
Accept